This work presents the seismic evaluation and the rehabilitation proposal of one essential facility, specifically the “Guillermo Luis” hospital of the Moa city in Holguín. The authors intend to apply, for the first time, a non-conventional technique used in Cuba to seismic protection of facilities health. This solution is based on seismic energy dissipation mechanisms, by mean of shear link device. The Shear Link-Bozzo device, allows the “GIRON” precast concrete systems to improve the inadequacies of behavior under earthquake lateral load by avoiding the undesired failure mechanism, such as: weak story and torsion due to great stiffness and mass asymmetries. All the above mentioned aspects drive us to take some alternative measures of seismic retrofit for these typical structures, based on the incorporation of the passive energy dissipation that allows the system to behave in the elastic range of response. By means of this solution it is possible to reduce the interference during the rehabilitation works, and also to reduce the time of break services of the hospital.
Cite this paper
Valdés, V. M. , Pupo, D. , Fernández, R. M. , Martínez, R. and Recarey, C. A. (2019). New Proposal for Seismic Rehabilitation of Hospitals in Cuba. Open Access Library Journal, 6, e5825. doi: http://dx.doi.org/10.4236/oalib.1105825.
Ruiz Ruiz, J.M. (2010) Evaluación de la seguridad sísmica de edificaciones prefabricadas 3 Simposio de edificios y sistema presforzados, Curso-Análisis y diseno de estructuras prefabricadas.
http://www.smie.org.mx/SMIE_Articulos/si/
si_07/te_01/ar_03.pdf
Noas Hernández, J.L. and Chuy Rodríguez, T.J. (2005) Caracterización de la amenaza sísmica de la ciudad de Moa, Provincia Holguín. VI Congreso de geología (Geología 2005) Simposio de Sismicidad y Riesgo Geológicos. Habana, Cuba.
Bozzo Rotondo, L.M. (2008) Numerical and Experimental Analysis of a Shear Link Energy Dissipator for Seismic Protection of Buildings. 14th World Conference on Earthquake Engineering, Beijing, 12-17 October 2008.
Nuzzo, I., Losanno, D., Serino, G. and Bozzo Rotondo, L.M. (2014) A Seismic-Resistant Precast R.C. System Equipped with Shear Link Dissipators for Residential Buildings. Proceedings of the Second International Conference on Advances in Civil, Structural and Environmental Engineering, Zurich, Switzerland, 25-26 October 2014, 249-254.
Bozzo, L.M., Cahis, X. and Torres, L.L. (1998) A Shear Type Energy Dissipator for the Protection of the Masonry Infill Walls. Proceedings of the Sixth U.S. National Conference on Earthquake Engineering, Seattle, WA.
Cahis, X., Torres, L. and Bozzo Rotondo, L.M. (2000) An Innovative Elasto-Plastic Energy Dissipator for the Structural and No-Structural Building Protection. 12th World Conference on Earthquake Engineering, Auckland, New Zealand, 1-8.
Nangullasmú Hernández, H.J. (2017) Modelado de disipadores histeréticos de energía en estructuras de concreto reforzado. Diferencias entre análisis en el plano y en tres dimensiones. Revista Internacional de Ingenierías de estructuras, 22, 135-162.
Aguiar, R., Bozzo, L., Mora, D., Silva, H., Caiza, P. and Coyago, H. (2016) Protocolo de instalación de disipadores shear link bozzo SLB40-3 y placas Gusset en bloque estructural 4 de la UFA-ESPE. Revista Internacional de Ingenierías de estructuras, 21, 127-150.
Valdés Jiménez, V.M., Pupo Ordono., D., Fernández Pérez, R.M. and Martinez Almaguer, R. (2017) Use of the Dissipator SL-B in the Rehabilitation of Health Facilities in Cuba. SMART 2017—Fourth Conference on Smart Monitoring, Assessment and Rehabilitation of Civil Structures, Suiza, 1-8.
https://data.smar-conferences.org/SMAR_2017_
Proceedings/papers/326.pdf