%0 Journal Article %T Fracturas del h¨²mero proximal: an¨¢lisis comparativo de resultados con placas de bloqueo angular fijo y poliaxial %A Pati£¿o %A Juan Mart¨ªn %A Mart¨ªnez %A Carlos Eugenio %A Riva %A Ra¨²l %A Andres %A Bernardo %A Verdi %A Germ¨¢n %A Soriano %A Roberto %A Garay %A Alberto %J Revista de la Asociaci£¿3n Argentina de Ortopedia y Traumatolog£¿-a %D 2010 %I Scientific Electronic Library Online %X background: there is still no agreement in the international literature about implant selection. the purpose of this study is to asses these two fixation types' functional results. methods: 29 patients, at 6 month follow-up, were retrospectively evaluated with the constant score, divided in two groups. group a (fixed angle locking plates, 17 patients) and group b (polyaxial locking plates, 12 patients). the neer classification was used for the preoperative evaluation. a deltopectoral approach was performed in all patients. results: 16 fractures in group a healed, 1 had to undergo revision surgery due to non- union. the constant score was 77.37 points. in group b all fractures healed, but 1 patient suffered aseptic necrosis of the humeral head, and another varus displacement. the constant score for this group was 75 points. conclusions: there was no difference in the clinical outcome between both fixation groups. in all patients, the constant score major improvement was due to the rom. the results of this study are similar to others in the literature about locking plates. %K proximal humerus %K fractures %K locking plates %K polyaxial locking plates. %U http://www.scielo.org.ar/scielo.php?script=sci_abstract&pid=S1852-74342010000100002&lng=en&nrm=iso&tlng=en