%0 Journal Article %T Pass/Fail Criterion for a Simple Radiation %A Tom Burr %A Avigdor Gavron %J Modern Instrumentation %P 27-33 %@ 2165-9273 %D 2012 %I Scientific Research Publishing %R 10.4236/mi.2012.13004 %X One of the simplest tests of a radiation portal monitor (RPM) is a series of n repeats (a vehicle drive-through) in which the ith repeat records a total number of counts Xi and alarms if Xi ¡Ý T where T is an alarm threshold. The RPM performance tests we consider use n repeats to estimate the probability p = P(Xi ¡Ý T). This paper addresses criterion A for testing RPMs, where criterion A is: for specified source strength, we must be at least 95% confident that p ¡Ý 0.5. To assess criterion A, we consider a distribution-free test and a test relying on assuming the counts Xi have approximately a Poisson distribution. Both test options require tolerance interval construction. %K Poisson Distribution %K Radiation Portal Monitor %K Tolerance Interval %U http://www.scirp.org/journal/PaperInformation.aspx?PaperID=21063