%0 Journal Article %T Avalia o audiom谷trica ap車s estapedotomia com pr車tese de titanio do tipo Fisch Audiometric evaluation after stapedotomy with Fisch titanium prosthesis %A Andre Luiz de Ataide %A Gerson Linck Bichinho %A Tatiana Mauad Patruni %J Brazilian Journal of Otorhinolaryngology %D 2013 %I Associa??o Brasileira de Otorrinolaringologia e Cirurgia Cervicofacial %X Otosclerose 谷 uma doen a que provoca fixa o do estribo, levando 角 perda auditiva tipicamente condutiva, corrigida com aparelhos auditivos ou cirurgia de estapedotomia, substituindo o estribo doente por uma pr車tese. O material mais recentemente utilizado 谷 o titanio e no Brasil h芍 apenas duas pr車teses comercialmente dispon赤veis. A pr車tese de pist o tipo Fisch, da Storz, n o possui resultados relatados na literatura. OBJETIVO: Estudo retrospectivo avaliando resultado auditivo ap車s estapedotomia com uso desta pr車tese. M谷TODO: Usando crit谷rios da Academia Americana de Otorrinolaringologia, comparou-se o gap nas audiometrias pr谷 e p車s-operat車rias, avaliando-se melhora auditiva. RESULTADOS: O gap p車s-operat車rio em baixas frequ那ncias teve m谷dia de 12,9 dB, em altas frequ那ncias de 5,2 dB (m谷dia 9,1 dB), mediana 8,8 dB, m赤nimo 1,3 dB e m芍ximo 21,6 dB, desvio padr o 5,7 e p < 0,001. Dividindo o resultado conforme o gap p車s-operat車rio a cada 10 dB, em 25 pacientes (75,8%) foi < ou igual a 10 dB, em 32 pacientes (96,9%) foi < ou igual a 20 dB, em 100% dos casos foi < ou igual a 30 dB. CONCLUS O: Pr車tese de pist o tipo Fisch apresenta resultados compat赤veis com a literatura, podendo ser usada com seguran a como mais uma boa op o para estapedotomia. Otosclerosis causes the fixation of the stapes and conductive hearing loss, usually corrected with the use of hearing aids or through stapedotomy and the replacement of the involved stapes with a prosthesis. Titanium has been the most recently used material of choice in stapedotomy prostheses. Only two prostheses are commercially available in Brazil. There are no reports in the literature on the Fisch-type Storz titanium stapes piston prosthesis. OBJECTIVE: This retrospective study aims to look into the auditory outcomes of patients submitted to stapedotomy and titanium stapes piston prosthesis implantation. METHOD: The criteria described by the American Academy of Otolaryngology were used to compare pre and postoperative air-bone gaps seen in audiometry tests. RESULTS: The mean low-frequency postoperative air-bone gap was 12.9 dB; the mean high-frequency air-bone gap was 5.2 dB (mean 9.1 dB); median gap was 8.8 dB, with a minimum of 1.3 dB and a maximum of 21.6 dB; standard deviation was 5.7 dB, and p < 0.001. Twenty-five (75.8%) patients had air-bone gaps of 10 dB and under; 32 (96.9%) patients had gaps of 20 dB and under; and all patients had gaps of 30 dB and under. CONCLUSION: The Fisch-type titanium stapes piston prosthesis presented outcomes consistent with the literature and can be used safely in stapedotomy pro %K otosclerose %K pr車teses e implantes %K substitui o ossicular %K titanio %K ossicular replacement %K otosclerosis %K prostheses and implants %K titanium %U http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1808-86942013000300011