%0 Journal Article %T 印度Jhajjar 660 MW超临界机组3号高压加热器泄露原因分析及对策
Reasons and Counterplans of Leakage of the Third High Pressure Heater in India Jhajjar 660 MW Supercritical Power Plant %A 张开利 %J Clean Coal and Energy %P 12-16 %@ 2334-3516 %D 2014 %I Hans Publishing %R 10.12677/CCE.2014.22003 %X
针对印度Jhajjar 660 MW超临界机组3号高压加热器发生泄露的情况,本文分析了加热器泄露的原因及危害,并提出了预防措施,经过实际运行检验,效果良好,可为同类型电厂提供参考。
In connection with the leakage situation of heater of 660 MW supercritical unit in India power plant, the article analyzes the reason and the harm of leakage of the heater, puts forward pro- cessing and preventive measures, and points out that through practical operation test, the effect is good. The result of this paper provides experience for similar units.
%K 加热器,泄漏,原因,对策
Heater %K Leakage %K Reason %K Counterplan %U http://www.hanspub.org/journal/PaperInformation.aspx?PaperID=13711