%0 Journal Article %T Measurement of Radon Gas Concentrations in Tap Water Samples for Thi-Qar Governorate Using Nuclear Track Detector (CR-39) %A Liath Ahmed Najam %A Hazim Louis Mansour %A Nada Fadhil Tawfiq %A Mahmood Salim Karim %J Detection %P 1-8 %@ 2331-2084 %D 2016 %I Scientific Research Publishing %R 10.4236/detection.2016.41001 %X In the present work, we have measured the radon gas concentrations in tap water samples are taken directly from drinking tap water in sites houses being carried in Thi-Qar governorate by using nuclear track detector (CR-39). The results of measurements have shown that the highest average radon concentration in water samples is found in AL-Refai region which is equal to (0.223 ¡À 0.03 Bq/L), while the lowest average radon gas concentration is found in AL-Fajr region which is equal to (0.108 ¡À 0.01 Bq/L), with an average value of (0.175 ¡À 0.03 Bq/L). The highest value of annual effective dose (AED) in tap water samples is found in AL-Refai region, which is equal to (0.814 ¦ÌSv/y), while the lowest value of (AED) is found in AL-Fajr region which is equal to (0.394 ¦ÌSv/y), with an average value of (0.640 ¡À 0.1 ¦ÌSv/y). The present results have shown that radon gas concentrations in tap water samples are less than the recommended international value (11.1 Bq/L). There for tap water in all the studied sites in Thi-Qar governorate is safe as for as radon concentration being concerned. %K Radon %K Solid State Nuclear Track Detectors %K CR-39 %K Radon in Water %U http://www.scirp.org/journal/PaperInformation.aspx?PaperID=61393