%0 Journal Article %T Obstructed or Malpositioned Urethral Catheter Induced Acute Kidney Injury %A Ankita Patel %A Eli A. Friedman %J Case Reports in Nephrology %D 2012 %I Hindawi Publishing Corporation %R 10.1155/2012/731502 %X Unanticipated renal failure may be induced by an obstructed urethral catheter that was a component of complex management or difficult insertion. Two patients with new-onset uremia due to obstructed urethral catheters evinced rapid return of renal function when their blocked catheters were replaced. %U http://www.hindawi.com/crim/nephrology/2012/731502/