%0 Journal Article %T Numerical simulation modeling of the irreversible electroporation treatment zone for focal therapy of prostate cancer, correlation with whole-mount pathology and T2-weighted MRI sequences %A Andreas Skolarikos %A Cees W.M. van den Geld %A Christopher B. Arena %A Daniel M. de Bruin %A Ioannis M. Varkarakis %A Jean de la Rosette %A Maria P. Laguna %A Matthijs J. Scheltema %A Phillip D. Stricker %A Rafael V. Davalos %A Robert E. Neal %A II %A Theo. M. de Reijke %A Tim J. OˇŻBrien %A Willemien van den Bos %J Archive of "Therapeutic Advances in Urology". %D 2019 %R 10.1177/1756287219852305 %X At present, it is not possible to predict the ablation zone volume following irreversible electroporation (IRE) for prostate cancer (PCa). This study aimed to determine the necessary electrical field threshold to ablate human prostate tissue in vivo with IRE %K electrical field %K focal therapy %K irreversible electroporation %K prostate %K prostate cancer %K simulation %U https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6557022/