%0 Journal Article %T Harmonic Resonance Analysis of Shale Gas Distribution Network with Phased Load %A Zhongjian Kang %A Lei Li %J Journal of Power and Energy Engineering %P 18-28 %@ 2327-5901 %D 2023 %I Scientific Research Publishing %R 10.4236/jpee.2023.111002 %X
Based on the background of achieving carbon peaking and carbon neutrality, the development and application of new high-power compressors, electric grid drilling RIGS and electric fracturing pump system provide new equipment support for the electric, green and intelligent development of shale gas fields in China. However, the harmonic pollution of shale gas grid becomes more serious due to the converter and frequency conversion device in the system, which easily causes harmonic resonance problem. Therefore, the harmonic resonance of shale gas grid is comprehensively analyzed and treated. Firstly, the working mechanism of compressor, electric drilling RIGS of the harmonic impedance model of electric fracturing pump system is established. Secondly, the main research methods of harmonic resonance analysis are introduced, and the basic principle of modal analysis is explained. Modal analysis method was used to analyze. Finally, harmonic resonance is suppressed. The results show that there may be multiple resonant frequency points in the distribution network changes, but these changes are relatively clear; if the original resonant frequency point of the resonant loop does not exist, the resonant frequency point disappears. The optimal configuration strategy of passive filter can effectively suppress harmonic resonance of distribution network in shale gas field.
%K Shale Gas Distribution Grid %K Harmonic Resonance %K Modal Analysis Method %K Active Power Filter %U http://www.scirp.org/journal/PaperInformation.aspx?PaperID=122849