全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...

Medición volumétrica de grasa visceral abdominal con RM y su relación con elastografía hepática en una población diabética

DOI: 10.4067/S0717-93082011000400008

Keywords: acoustic radiation force impulse, diabetes mellitus type 2, fat assessment, intra-abdominal fat, magnetic resonance imaging, nonalcoholic fatty liver disease, transient elastography, visceral adipose tissue.

Full-Text   Cite this paper   Add to My Lib

Abstract:

background. increase in visceral fat is associated to the development of fatty liver and liver fibrosis. hepatic elastography is a novel noninvasive method for assessing liver fibrosis. objective. to evaluate the relationship between visceral adipose tissue volume (vat), subcutaneous adipose tissue volume (sat) as measured by magnetic resonance imaging (mri) and transient elastography (tre) values using arfi (acoustic radiation force impulse) in type 2 diabetic mellitus patients (dm2). methods. we included 20 dm2 patients (mean age: 62 years, range: 55-75, mean weight: 77.8 kg, range: 61.5-97). patients underwent an mri study in a philips intera 1.5t scanner. mr imaging protocol included a spectral excitation sequence centered on the fat peak. the sequence included 32 cross sections, 7mm thick, from the diaphragmatic cupula to the inferior border of the kidney. vat was measured by using the semiautomatic image j software. each patient underwent a hepatic elastograpy (he); 10 arfi measurements were performed in the right hepatic lobe. finally, a statistical analysis was performed by applying pearson correlation between abdominal fat volumes and arfi scores results. mean vat was 2472 ± 861 cc, (1173-4020 cc), whilst the mean arfi was 1.62 ± 0.8 m/s, (0.8-3.4 m/s). correlations obtained were r=0.08 between vat and arfi (p=0.72); 0.13 between sat and arfi (p=0.57), and -0.06 between (vat+sat) and arfi (p=0.77). by subdividing the sample universe, we observed that the group with arfi scores greater than 1.6 m/s (7 patients) had a correlation of 0.63 between vat and arfi (p=0.12); of 0.66 between sat and arfi (p=0.10), and of 0.94 between vat+sat and arfi (p=0.001). in the subgroup with arfi values inferior to 1.6 m/s (13 patients), the correlation was of 0.11 between vat and arfi (p=0.71); of 0.26 between sat and arfi (p=0.38), and of 0.32 between ( vat+sat) and arfi (p=0.28). when adjusted for gender, arfi scores greater than 1.6m/s (6 patients) in the subgroup of femal

Full-Text

Contact Us

[email protected]

QQ:3279437679

WhatsApp +8615387084133