全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...

Synovial fluid sedimentation in the immobile patient: a commentary on modern septic arthritis and the addition of a new variable confounding diagnosis

DOI: http://dx.doi.org/10.2147/ORR.S30800

Keywords: septic arthritis, inflammatory arthritis, joint, sedimentation, orthopedic

Full-Text   Cite this paper   Add to My Lib

Abstract:

ovial fluid sedimentation in the immobile patient: a commentary on modern septic arthritis and the addition of a new variable confounding diagnosis Commentary (455) Total Article Views Authors: Cunningham G, Ricciardo B Published Date January 2013 Volume 2013:5 Pages 1 - 4 DOI: http://dx.doi.org/10.2147/ORR.S30800 Received: 11 February 2012 Accepted: 06 March 2012 Published: 11 January 2013 Gregory Cunningham,1 Brendan Ricciardo2 1Royal Perth Hospital, Perth, Western Australia, Australia; 2Bunbury Regional Hospital, Bunbury, Western Australia, Australia Abstract: Septic arthritis is a serious cause of morbidity and mortality. Despite recent advances, monoarticular and polyarticular septic arthritis (SA) have a mortality rate of approximately 11% and 30%, respectively. SA has a 40% risk of permanent loss of joint function. Diagnosis of SA is difficult, given that no rapidly available individual test proves 100% sensitive or 100% specific. There are no previous reports on the phenomenon of synovial fluid sedimentation in an immobile patient, although the occurrence has been identified in vitro. This commentary also presents an extended report of a patient who had been immobile and supine for 24 hours before her right knee was aspirated and treated for septic arthritis. Due to her immobilization, the synovial fluid had settled. The color and opacity of the sequential aliquots from one arthrocentesis was noted to change from light straw-colored, to thick opaque purulent material. Laboratory reports showed increasing white cell counts (WCCs), from 2.6 × 109 to 78 × 109 between the sequential samples. This demonstrates a newly identified phenomenon of sedimentation. This might have led to a diagnostic difficulty, had the knee not been fully aspirated. Aspiration serves as a diagnostic tool, because it collects a sample, but it also serves as a treatment measure, because it removes purulent material. Complete aspiration of the joint should be performed for full therapeutic benefit and to avoid the potential diagnostic confusion of a falsely low WCC due to this newly identified phenomenon of synovial fluid sedimentation in the immobile patient.

Full-Text

comments powered by Disqus

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133