Detection accuracy of three glucose meters estimated by capillary blood glucose measurements compared with venous blood evaluated by the diabetes unit of the Hospital Evangélico de Curitiba, Brazil

DOI: http://dx.doi.org/10.2147/RRED.S24631

Keywords: capillary blood glucose, serum glucose, glucose meters, hospitalized patients

Full-Text   Cite this paper   Add to My Lib

Abstract:

ection accuracy of three glucose meters estimated by capillary blood glucose measurements compared with venous blood evaluated by the diabetes unit of the Hospital Evangélico de Curitiba, Brazil Original Research (1588) Total Article Views Authors: Gama MP, Cruzeta CF, Ossowski AC, Bay MR, Michaelis MM, Camacho SL Published Date May 2012 Volume 2012:2 Pages 1 - 9 DOI: http://dx.doi.org/10.2147/RRED.S24631 Received: 28 July 2011 Accepted: 21 October 2011 Published: 22 May 2012 Mirnaluci Paulino Ribeiro Gama, Camile Fiorese Cruzeta, Ana Carolina Ossowski, Marina Rech Bay, Mariella Muller Michaelis, Stênio Lujan Camacho Endocrinology and Diabetes Service, Hospital Universitário Evangélico de Curitiba, Brazil Objective: To compare capillary blood glucose measurements between three different glucose meters and with the serum glucose values of inpatients at the diabetes unit of Hospital Universitário Evangélico de Curitiba, Brazil. Materials and methods: A total of 132 non-intensive care unit patients admitted for medical and surgical pathologies were evaluated. All patients reported a previous diagnosis of diabetes mellitus, were under 60 years of age, had no hematocrit alterations, remained hemodynamically stable during the time of data collection, and were given no ascorbic acid, acetaminophen, dopamine, or mannitol during follow-up. Capillary and serum blood glucose samples were collected simultaneously by finger-stick and venipuncture 2 hours after lunch, by the same observer, who was blinded to the serum glucose results. First, between July and November 2009, capillary glucose levels were measured using the blood glucose meters OneTouch SureStep and MediSense Optium . Between November 2009 and February 2010, capillary blood glucose levels were measured on the glucose meters OneTouch SureStep and Optium Xceed . The capillary glucose readings were analyzed between meters and also in relation to the serum blood glucose values by the t-test for paired samples and the Mood two-sample test. Results: The patients’ mean age was 50.45 years. The blood glucose means obtained using the meters OneTouch SureStep, MediSense Optium, and Optium Xceed were, respectively, 183.87 mg/dL, 178.49 mg/dL, and 192.73 mg/dL, and the mean for the serum glucose values was 174.58 mg/dL. A significant difference was found between the capillary measurements taken by the glucose meters and the serum glucose measurements (P < 0.05), and no significant interdevice difference was found. After stratification of the serum blood glucose values into two groups, below and above 180 mg/dL, the variance found for the glucose meter OneTouch SureStep was statistically greater (P = 0.03) in relation to the serum glucose levels above 180 mg/dL, which was not the case with the glucose meters MediSense Optium (P = 0.06) and Optium Xceed (P = 0.12). The percentage of capillary blood glucose values showing a variation of less than 20% compared with serum values was 64.94% for OneTouch SureStep,

Full-Text

Contact Us

[email protected]

QQ:3279437679

WhatsApp +8615387084133