全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...

Municipality of Cluj-Napoca – The Quality of Wastewaters. Note 1. Monitoring Disolved Oxygen

Keywords: oxygen deficit , instrumental analyze , amperometry

Full-Text   Cite this paper   Add to My Lib

Abstract:

The results of monitoring the disolved oxygen from municipal wastewater collected from the Cluj – Napocachannels network are presented in this paper. Monitoring was performed during one year and five months. The watersamples were harvested from three distinct areas of the same municipal collection channel (Canalul Morii – M r stiquarter, Canalul Morii - Parcul Mare and Paraul Popii – inside of the University of Agricultural Sciences and VeterinaryMedicine Cluj – Napoca). The samples were instumentally analyzed (amperometry) and statistical processed withSTATISTICA v. 7.0. During entire experimental time interval, values that did not exceed the established limits fordisolved oxygen in water were recorded. An average of 4.50 mg/L was obtained by entire experimental time intervalwith a maxim of 4.92 mg/L and a minim of 4.23 mg/L.

Full-Text

comments powered by Disqus

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133