Studiul structurii betonului ca mediu de protec ie a arm turilor mpotriva coroziunii

Keywords: corrosion in concrete structures , rate of corrosion , cracks in concrete , aggressiveness of the medium

Full-Text   Cite this paper   Add to My Lib

Abstract:

The paper presents a study of the processes of reinforcementcorrosion in concrete structures as a consequence of aggressive infiltration of water through cracks in the concrete. The rate of corrosion of reinforcement in concrete depends on the density and moisture content of concrete. Determine the effect of relative humidity (60 %, 80 %, 95 %) on the rate of reinforcement corrosion, cracks in the zone, held in thermohydrostatic cells at 50 ° C, at high concentrations of oxygen and carbon dioxide than the environment. Duration of tests, depending on the degree of aggressiveness of the medium ranged from several days to severalmonths. During the tests, controlled temperature, relative humidity, gas concentration, humidity of the concrete and the environment. Whenhumidity variation from 35 to 60 %, the resistance of concrete increases slightly. With increasing relative humidity up to 80 % or more, the ohmic resistance decreases and the corrosion of reinforcement can have rapid development.