全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...

Variation in heart rate influences the assessment of transient ischemic dilation in myocardial perfusion scintigraphy

DOI: 10.1186/1471-2385-7-1

Full-Text   Cite this paper   Add to My Lib

Abstract:

Consecutive patients undergoing stress/rest sestamibi gated myocardial perfusion scintigraphy were studied (N = 407). Heart rate at the time of stress and rest imaging were recorded. TID ratios were analyzed in relation to absolute change in heart rate (stress minus rest) for subjects with normal perfusion and systolic function (Group 1, N = 169) and those with abnormalities in perfusion and/or function (Group 2, N = 238).In Group 1, mean TID ratio was inversely correlated with the change in heart rate (r = -0.47, P < 0.0001). For every increase of 10 BPM in heart rate change, the TID ratio decreased by approximately 0.06 (95% confidence interval 0.04–0.07). In Group 2, multiple linear regression demonstrated that the change in heart rate (beta = -0.25, P < 0.0001) and the summed difference score (beta = 0.36, P < 0.0001) were independent predictors of the TID ratio.Normal variation in heart rate between the stress and rest components of myocardial perfusion scans is common and can influence TID ratios in patients with normal and abnormal cardiac scans.The assessment of myocardial perfusion with radioactive flow tracers provides valuable clinical information for diagnosis and risk stratification [1-3]. Individuals with normal myocardial perfusion during an adequate stress procedure are generally regarded as being at low risk for major cardiac events [4,5]. In addition to perfusion, a number of ancillary functional parameters can be extracted from these images [6]. These have been shown to provide additional prognostic information that is additive to the clinical and perfusion data alone. For example, left ventricular systolic function can be assessed with gated single photon emission computed tomography (SPECT), left ventricular cavity size can be measured, and lung uptake measurements can be computed [7-11]. Each of these parameters has been shown to provide incremental prognostic information."Transient ischemic dilation" (TID) of the left ventricular cavity is a m

Full-Text

comments powered by Disqus

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133

WeChat 1538708413