Micromachines  2013 

Active Continuous-Flow Micromixer Using an External Braille Pin Actuator Array

DOI: 10.3390/mi4010080

Keywords: active micromixer, continuous-flow, chaotic advection, channel wall deflection, PDMS chip, cell sample dilution, microfluidic Braille pin actuated platform

Full-Text   Cite this paper   Add to My Lib

Abstract:

We present a continuous-flow active micromixer based on channel-wall deflection in a polydimethylsiloxane (PDMS) chip for volume flows in the range up to 2?μL s ?1 which is intended as a novel unit operation for the microfluidic Braille pin actuated platform. The chip design comprises a main microchannel connected to a series of side channels with dead ends aligned on the Braille pins. Computer-controlled deflection of the side-channel walls induces chaotic advection in the main-channel, which substantially accelerates mixing in low-Reynolds number flow. Sufficient mixing (mixing index MI below 0.1) of volume flows up to 0.5 μL s ?1 could be achieved within residence times ~500 ms in the micromixer. As an application, continuous dilution of a yeast cell sample by a ratio down to 1:10 was successfully demonstrated. The mixer is intended to serve as a component of bio-analytical devices or as a unit operation in the microfluidic Braille pin actuated platform.

References

[1]  Nguyen, N.-T. Micromixers, Fundamental, Design and Fabriaction, 2nd ed.; Elsevier: Waltham, MA, USA, 2012.
[2]  Jeong, G.S.; Chung, S.; Kim, C.B.; Lee, S.H. Applications of micromixing technology. Analyst 2010, 135, 460–473, doi:10.1039/b921430e.
[3]  Nguyen, N.-T.; Wu, Z. Micromixers—a review. J. Micromech. Microeng. 2005, 15, R1–R16, doi:10.1088/0960-1317/15/2/R01.
[4]  Tabeling, P.; Chabert, M.; Dodge, A.; Jullien, C.; Okkels, F. Chaotic mixing in cross-channel micromixers. Philos. Transact. A Math. Phys. Eng. Sci. 2004, 362, 987–1000, doi:10.1098/rsta.2003.1358.
[5]  Gouillart, E.; Dauchot, O.; Thiffeault, J.L. Measures of mixing quality in open flows with chaotic advection. Phys. Fluids 2011, 23, doi:10.1063/1.3506817.
[6]  Stroock, A.D.; Dertinger, S.K.W.; Ajdari, A.; Mezi?, I.; Stone, H.A.; Whitesides, G.M. Chaotic mixer for micro channels. Science 2002, 295, 647–651, doi:10.1126/science.1066238.
[7]  Liu, R.H.; Stremler, M.A.; Sharp, K.V.; Olsen, M.G.; Santiago, J.G.; Adrian, R.J.; Aref, H.; Beebe, D.J. Passive mixing in a three-dimensional serpentine microchannel. J. Microelectromech. Syst. 2000, 9, 190–197, doi:10.1109/84.846699.
[8]  Jen, C.P.; Wu, C.Y.; Lin, Y.C. Design and simulation of the micromixer with chaotic advection in twisted micro channels. Lab Chip 2003, 3, 77–81, doi:10.1039/b211091a.
[9]  Xia, H.; Wan, S.; Shu, C.; Chew, Y. Chaotic micromixers using two-layer crossing channels to exhibit fast mixing at low Reynolds numbers. Lab Chip 2005, 5, 748–755, doi:10.1039/b502031j.
[10]  Lu, L.H.; Ryu, K.S.; Liu, C. A magnetic microstirrer and array for microfluidic mixing. J. Microelectromech. Syst. 2002, 11, 462–469, doi:10.1109/JMEMS.2002.802899.
[11]  Tekin, H.C.; Sivagnanam, V.; Ciftlik, A.T.; Sayah, A.; Vandevyver, C.; Gijs, M.A.M. Chaotic mixing using source–sink microfluidic flows in a PDMS chip. Microfluid. Nanofluid. 2011, 10, 749–759, doi:10.1007/s10404-010-0706-0.
[12]  Lee, Y.K.; Deval, J.; Tabeling, P.; Ho, C.M. Chaotic mixing in electrokinetically and pressure driven micro flows. In Proceedings of the 14th IEEE International Conference on Micro Electro Mechanical Systems, Interlaken, Switzerland, 21–25 January 2001; pp. 483–486.
[13]  Gu, W.; Zhu, X.; Futai, N.; Cho, B.S.; Takayama, S. Computerized microfluidic cell culture using elastomeric channels and Braille displays. Proc. Natl. Acad. Sci. USA 2004, 101, 15861–15866.
[14]  Erickson, B.E. Braille pins control microfluidic flow. Anal. Chem. 2005, 77, 93–93, doi:10.1021/ac0401218.
[15]  Duffy, D.C.; McDonald, J.C.; Schueller, O.J.A.; Whitesides, G.M. Rapid prototyping of microfluidic systems in poly (dimethylsiloxane). Anal. Chem. 1998, 70, 4974–4984, doi:10.1021/ac980656z.
[16]  Futai, N.; Gu, W.; Song, J.W.; Takayama, S. Handheld recirculation system and customized media for microfluidic cell culture. Lab Chip 2005, 6, 149–154.
[17]  BioFluidix GmbH Web site. Available online: http://www.biofluidix.com (accessed on 3 November 2012).
[18]  Mao, X.; Juluri, B.K.; Lapsley, M.I.; Stratton, Z.S.; Huang, T.J. Milliseconds microfluidic chaotic bubble mixer. Microfluid. Nanofluid. 2010, 8, 139–144, doi:10.1007/s10404-009-0496-4.
[19]  Lange, H.; Taillandier, P.; Riba, J.P. Effect of high shear stress on microbial viability. J. Chem. Technol. Biotechnol. 2001, 76, 501–505, doi:10.1002/jctb.401.

Full-Text

comments powered by Disqus

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133

WeChat 1538708413