全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...

PREDICTION OF DENSITY AND VISCOSITY OF COLOMBIAN CRUDE OILS FROM CHROMATOGRAPHIC DATA

Keywords: Regresión multivariada , Petróleo colombiano , Cromatografía , Densidad , Viscosidad , Regress o multivariada , Petróleo colombiano , Cromatografia , Densidade , Viscosidade , Multivariate regression , Colombian oil , Gas chromatography , Density , Viscosity

Full-Text   Cite this paper   Add to My Lib

Abstract:

The aim of our work was to analyze the use of Gas Chromatographic (GC) data for correlating bulk properties of Colombian crude oils. Multivariate statistics regressions were applied on a set of 57 Colombian crude oil chromatograms to correlate both density and kinematic viscosity (Vk); this last one property in terms of the Refutas viscosity index (V50). Principal component analysis applied to the GC signals indicated that the responses for the more volatile compounds, which elute up to 5 min of recorded retention times, can be excluded from the data analysis to get better distribution of the score and loading plots. Principal Component Regression (PCR) and Partial Least Squares (PLS) methods were applied to the GC signals pre-processed with different strategies. Strategy of total area normalization applied on the chromatograms without the first 5 min of the recorded times produced the best performance for predicting density and V50 in both PCR and PLS (strategies named as PCR2-5 and PLS2-5, respectively). The density models using PLS2-5 required just one PC for explaining 88,6% of the total variance. However, this model generated appreciable errors compared to those reported by the Near Infrared models and the reproducibility and repeatability reported in the ASTM D5002. PLS2-5 also yielded large errors when calculating Vk from the regression of V50. Through the inclusion of the chromatographic Distillable Fraction (DF) and some mathematical transformations, the accuracy for the predictive model of Vk was improved. Notwithstanding this, performance of the regression based on GC data was lower compared to the corresponding Nuclear Magnetic Resonance models. Validations of the regressions with PLS2-5 reported average relative errors for density and kinematic viscosity (predicted in terms of DF*Ln(Vk)) of 1,4 and 29%, respectively, which are surprisingly low given the appreciable amount of chromatographic residue in several crudes. Despite having a higher experimental error in the chromatographic method in comparison to that found when using spectroscopic method in chemo-chemistry, the regression models proposed in this work can provide useful preliminary information for assay evaluation and have the potential to be improved and extended to crude oil fractions using the same FID signal recorded from the crude. El objetivo de nuestra investigación es analizar el uso de la cromatografía de gases en la correlación de propiedades de crudos colombianos. Diferentes análisis de estadística multivariada fueron aplicados a 57 cromatogramas de fase gaseosa de crudos

Full-Text

comments powered by Disqus

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133

WeChat 1538708413