全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...

Determination of Benzene, Toluene and Xylene (BTX) Concentrations in Air Using HPLC Developed Method Compared to Gas Chromatography

Keywords: Volatile Organic Compounds , Gas Chromatography , Air

Full-Text   Cite this paper   Add to My Lib

Abstract:

A new method for analysis of benzene, toluene, and xylene (BTX) using High Performance Liquid Chromatography-UV detection (HPLC-UV) is described and compared to the gas chromatography (GC) method. A charcoal adsorption tube connected to a small pump was used to obtain samples from an atmosphere chamber standard. Samples were extracted with methanol and analyzed by HPLC-UV. Chromatography was isocratic in a mobile phase consisting of water-methanol (30-70). The flow rate was set at 1 ml/min. The analyses were completely separated and were quantified using both methods. The results demonstrated no statistically significant differences between BTX concentrations between the two analytical methods with a correlation coefficient of 0.98-0.99. The GC method provided higher sensitivity than HPLC, but the HPLC determination of BTX were applicable to real samples because its sensivity was lower than the thershold limit recommended by the American Conference of Governmental Industrial Hygienist (ACGIH) for an 8-hour workday.

Full-Text

comments powered by Disqus

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133