Experimental Characterization of a Thermopile with Aluminum-n-type Polysilicon Junctions as a Base for Multi-directional Flow Sensor Implemented in a Silicon Chip

Keywords: flow sensor , thermopile , Seebeck effect

Full-Text   Cite this paper   Add to My Lib

Abstract:

A multi-directional flow sensor has been realized. The essential part of the considered sensor is a thermopile configuration, which enables the measurement of the flow speed and the flow direction. The thermopile is a series arrangement of eight thermocouples. A thermocouple converts a difference in temperature into an electrical signal, by means of the Seebeck effect. The thermocouples are made of aluminum-N-type polysilicon junctions. The incoming flow is heated and the degree of heat transfer by convection to the flow, depends on the speed of the flow; the faster the flow the smaller the heat transfer, which leads to a smaller (Seebeck) output voltage of the thermopiles. After signal conditioning - i.e., filtering and amplification by means of an amplification system - the electrical output signals of the thermopiles are further signal-processed by applying analog-to-digital signal conversion, so that finally the flow speed and flow direction can be properly displayed on a computer screen. The measured values of the thermopower were in the range of: 0.433 mV/K to 0.6754 mV/K, which are in good agreement with the values found in the literature: 0.5 to 0.7 mV/K. In addition it was found that the flow speed U is proportional to the reciprocal value of the square root of the output voltage of the outgoing thermopile.

Full-Text

comments powered by Disqus

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133

WeChat 1538708413