全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...

Full-Field and Single-Shot Full-Field Optical Coherence Tomography: A Novel Technique for Biomedical Imaging Applications

DOI: 10.1155/2012/435408

Full-Text   Cite this paper   Add to My Lib

Abstract:

Since its introduction, optical coherence tomography (OCT) technology has advanced dramatically in various field of both clinical and fundamental research. Full-field and Single-shot full-field OCT (FF-OCT and SS-FF-OCT) are alternative OCT concepts, which aims to improve the image acquisition speed and to simplify the optical setup of conventional point-scan OCT by realizing direct line field or full-field sample imaging onto an array or line detector such as CCD or CMOS camera. FF-OCT and SS-FF-OCT are based on bulk optics Linnik-type Michelson interferometer with relatively high numerical aperture (NA) microscopic objectives. This paper will give you an overview of the principle of various types of FF-OCT and SS-FF-OCT techniques and its associated system design concept and image reconstruction algorithms. 1. Introduction Optical coherence tomography (OCT) is a novel noninvasive optical imaging modality based on low-coherence interferometry. The first version of this technique was devised in 1990 by Dr. Naohiro Tanno, a professor at Yamagata University [1, 2], and then perfected in 1991 by Massachusetts Institute of Technology team headed by Professor James Fujimoto [3]. OCT can enable the noninvasive, noncontact imaging of cross-sectional structures in biological tissues and materials with high resolution. In principle, OCT is an optical analogue to clinical ultrasound. In OCT, the temporally gated back-reflected optical pulse remitted from scattering sites within the sample is localized by low-coherence interferometry (LCI) [4–8]. This is typically achieved with a Michelson interferometer. The sample rests in one arm of the interferometer, and a scanning reference optical delay line comprises the other arm. In LCI, light interferes at the detector only when light reflected from the sample is matched in pathlength to light reflected from the scanning reference mirror. A single scan of the reference mirror thus provides a one-dimensional reflectivity profile of the sample. Two-dimensional cross-sectional images are formed by laterally scanning the incident probe beam across the sample. The reconstructed OCT images are essentially a map of the changes in the refractive index of refraction that occurs at internal interfaces. Just like ultrasound images, the discontinuities in acoustic impedance occur. The principle difference between ultrasound and optical imaging is that the velocity of light is approximately a million times faster than the velocity of sound. For this reason, the distance within the materials or tissues with a resolution of 10?μm by

References

[1]  N. Tanno, T. Ichikawa, and A. Saeki, “Lightwave Reflection Measurement” (Japanese), Japanese Patent # 2010042, 1990.
[2]  S. Chiba and N. Tanno, “Backscattering Optical Heterodyne Tomography, prepared for the 14th Laser Sensing Symposium” (Japanese), 1991.
[3]  D. Huang, E. A. Swanson, C. P. Lin et al., “Optical coherence tomography,” Science, vol. 254, no. 5035, pp. 1178–1181, 1991.
[4]  A. F. Fercher, K. Mengedoht, and W. Werner, “Eye-length measurement by interferometry with partially coherent light,” Optics Letters, vol. 13, no. 3, pp. 186–188, 1988.
[5]  C. K. Hitzenberger, W. Drexler, and A. F. Fercher, “Measurement of corneal thickness by laser Doppler interferometry,” Investigative Ophthalmology and Visual Science, vol. 33, no. 1, pp. 98–103, 1992.
[6]  J. A. Izatt, M. R. Hee, E. A. Swanson et al., “Micrometer-scale resolution imaging of the anterior eye in vivo with optical coherence tomography,” Archives of Ophthalmology, vol. 112, no. 12, pp. 1584–1589, 1994.
[7]  X. Clivaz, F. Marquis-Weible, R. P. Salathe, R. P. Novak, and H. H. Gilgen, “High-resolution reflectometry in biological tissue,” Optics Letters, vol. 17, pp. 4–6, 1992.
[8]  J. M. Schmitt, A. Knüttel, and R. F. Bonner, “Measurement of optical properties of biological tissues by low-coherence reflectometry,” Applied Optics, vol. 32, no. 30, pp. 6032–6042, 1993.
[9]  G. Hausler and M. W. Lindner, “Coherence radar and spectral radar—new tools for dermatological diagnosis,” Journal of Biomedical Optics, vol. 3, no. 1, pp. 21–31, 1998.
[10]  A. F. Fercher, C. K. Hitzenberger, G. Kamp, and S. Y. El-Zaiat, “Measurement of intraocular distances by backscattering spectral interferometry,” Optics Communications, vol. 117, no. 1-2, pp. 43–48, 1995.
[11]  R. Leitgeb, C. K. Hitzenberger, and A. F. Fercher, “Performance of fourier domain vs. time domain optical coherence tomography,” Optics Express, vol. 11, no. 8, pp. 889–894, 2003.
[12]  M. A. Choma, M. V. Sarunic, C. H. Yang, and J. A. Izatt, “Sensitivity advantage of swept source and Fourier domain optical coherence tomography,” Optics Express, vol. 11, no. 18, pp. 2183–2189, 2003.
[13]  J. F. de Boer, B. Cense, B. H. Park, M. C. Pierce, G. J. Tearney, and B. E. Bouma, “Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography,” Optics Letters, vol. 28, no. 21, pp. 2067–2069, 2003.
[14]  B. Pova?ay, A. Unterhuber, B. Hermann, H. Sattmann, H. Arthaber, and W. Drexler, “Full-field time-encoded frequency-domain optical coherence tomography,” Optics Express, vol. 14, no. 17, pp. 7661–7669, 2006.
[15]  M. Wojtkowski, A. Kowalczyk, R. Leitgeb, and A. F. Fercher, “Full range complex spectral optical coherence tomography technique in eye imaging,” Optics Letters, vol. 27, no. 16, pp. 1415–1417, 2002.
[16]  R. A. Leitgeb, M. Villiger, A. H. Bachmann, L. Steinmann, and T. Lasser, “Extended focus depth for Fourier domain optical coherence microscopy,” Optics Letters, vol. 31, no. 16, pp. 2450–2452, 2006.
[17]  J. G. Fujimoto, “Optical coherence tomography for ultrahigh resolution in vivo imaging,” Nature Biotechnology, vol. 21, no. 11, pp. 1361–1367, 2003.
[18]  W. Drexler, U. Morgner, F. X. Kartner et al., “In vivo ultrahigh-resolution optical coherence tomography,” Optics Letters, vol. 24, no. 17, pp. 1221–1223, 1999.
[19]  M. E. Brezinski, G. J. Tearney, S. A. Boppart, et al., “High speed catheter based OCT imaging of coronary microstructure,” Circulation, vol. 94, no. 8, p. 1494, 1996.
[20]  E. Beaurepaire, B. A. CLebec, L. MBlanchot, and H. Saint-Jalmes, “Full-field optical coherence tomography,” Optics Letters, vol. 23, pp. 244–246, 1998.
[21]  A. Dubois, A. C. Boccara, and M. Lebec, “Real-time reflectivity and topography imagery of depth-resolved microscopic surfaces,” Optics Letters, vol. 24, no. 5, pp. 309–311, 1999.
[22]  E. Bordenave, E. Abraham, G. Jortusauskas, J. Oberle, and C. Rullière, “Longitudinal imaging in biological tissues with a single-shot correlation system,” Optics Express, vol. 10, no. 1, pp. 35–40, 2002.
[23]  K. Grieve, A. Dubois, M. Simonutti et al., “In vivo anterior segment imaging in the rat eye with high speed white light full-field optical coherence tomography,” Optics Express, vol. 13, no. 16, pp. 6286–6295, 2005.
[24]  G. S. Kino and S. S. C. Chim, “Mirau correlation microscope,” Applied Optics, vol. 29, no. 26, pp. 3775–3783, 1990.
[25]  M. Davidson, K. Kaufman, I. Mazor, and F. Cohen, “An application of interference microscope to integrated circuit inspection and metrology,” in Integrated Circuit Metrology, Inspection and Process Control, vol. 775 of Proceedings of the SPIE, pp. 233–247, 1987.
[26]  A. Dubois, L. Vabre, A. C. Boccara, and E. Beaurepaire, “High-resolution full-field optical coherence tomography with a Linnik microscope,” Applied Optics, vol. 41, no. 4, pp. 805–812, 2002.
[27]  B. E. Bouma and G. J. Tearney, Eds., Handbook of Optical Coherence Tomography, Marcel Dekker, New York, NY, USA, 2003.
[28]  I. Abdulhalim, “Competence between spatial and temporal coherence in full field optical coherence tomography and interference microscopy,” Journal of Optics A, vol. 8, no. 11, pp. 952–958, 2006.
[29]  W. Y. Oh, B. E. Bouma, N. Iftimia, S. H. Yun, R. Yelin, and G. J. Tearney, “Ultrahigh-resolution full-field optical coherence microscopy using InGaAs camera,” Optics Express, vol. 14, no. 2, pp. 726–735, 2006.
[30]  A. Dubois, K. Grieve, G. Moneron, R. Lecaque, L. Vabre, and C. Boccara, “Ultrahigh-resolution full-field optical coherence tomography,” Applied Optics, vol. 43, no. 14, pp. 2874–2883, 2004.
[31]  J. Millerd, N. Brock, J. Hayes, M. North-Morris, M. Novak, and J. Wyant, “Pixelated phase-mask dynamic interferometer,” in Proceedings of the Interferometry XI, vol. 5531 of Proceedings of SPIE, pp. 304–314, Denver, Colo, USA, 2004.
[32]  C. Dunsby, Y. Gu, and P. French, “Single-shot phase-stepped wide-field coherence-gated imaging,” Optics Express, vol. 11, no. 2, pp. 105–115, 2003.
[33]  A. F. Fercher, C. K. Hitzenberger, M. Sticker et al., “A thermal light source technique for optical coherence tomography,” Optics Communications, vol. 185, no. 1–3, pp. 57–64, 2000.
[34]  B. Karamata, P. Lambelet, M. Laubscher, R. P. Salathé, and T. Lasser, “Spatially incoherent illumination as a mechanism for cross-talk suppression in wide-field optical coherence tomography,” Optics Letters, vol. 29, no. 7, pp. 736–738, 2004.
[35]  W. Drexler, “Ultrahigh-resolution optical coherence tomography,” Journal of Biomedical Optics, vol. 9, no. 1, pp. 47–74, 2004.
[36]  A. F. Fercher, W. Drexler, C. K. Hitzenberger, and T. Lasser, “Optical coherence tomography—principles and applications,” Reports on Progress in Physics, vol. 66, no. 2, pp. 239–303, 2003.
[37]  K. Creath, “Phase measurement interferometry techniques,” in Progress in Optics, E. Wolf, Ed., vol. 24, pp. 349–393, Elsevier Science, Amsterdam, The Netherlands, 1988.
[38]  L. Vabre, A. Dubois, and A. C. Boccara, “Thermal-light full-field optical coherence tomography,” Optics Letters, vol. 27, no. 7, pp. 530–532, 2002.
[39]  E. Bordenave, E. Abraham, G. Jonusauskas et al., “Wide-field optical coherence tomography: imaging of biological tissues,” Applied Optics, vol. 41, no. 10, pp. 2059–2064, 2002.
[40]  M. Akiba, K. P. Chan, and N. Tanno, “Full-field optical coherence tomography by two-dimensional heterodyne detection with a pair of CCD cameras,” Optics Letters, vol. 28, no. 10, pp. 816–818, 2003.
[41]  M. Akiba and K. P. Chan, “In vivo video-rate cellular-level full-field optical coherence tomography,” Journal of Biomedical Optics, vol. 12, no. 6, Article ID 064024, 2007.
[42]  M. Sato, T. Nagata, T. Niizuma, L. Neagu, R. Dabu, and Y. Watanabe, “Quadrature fringes wide-field optical coherence tomography and its applications to biological tissues,” Optics Communications, vol. 271, no. 2, pp. 573–580, 2007.
[43]  K. Grieve, A. Dubois, M. Simonutti et al., “In vivo anterior segment imaging in the rat eye with high speed white light full-field optical coherence tomography,” Optics Express, vol. 13, no. 16, pp. 6286–6295, 2005.
[44]  Y. Watanabe and M. Sato, “Three-dimensional wide-field optical coherence tomography using an ultrahigh-speed CMOS camera,” Optics Communications, vol. 281, no. 7, pp. 1889–1895, 2008.
[45]  Z. P. Chen, T. E. Milner, D. Dave, and J. S. Nelson, “Optical Doppler tomographic imaging of fluid flow velocity in highly scattering media,” Optics Letters, vol. 22, no. 1, pp. 64–66, 1997.
[46]  D. P. Dave, T. Akkin, and T. E. Milner, “Polarization-maintaining fiber-based optical low-coherence reflectometer for characterization and ranging of birefringence,” Optics Letters, vol. 28, no. 19, pp. 1775–1777, 2003.
[47]  J. F. de Boer and T. E. Milner, “Review of polarization sensitive optical coherence tomography and Stokes vector determination,” Journal of Biomedical Optics, vol. 7, no. 3, pp. 359–371, 2002.
[48]  D. T. Miller, J. Qu, R. S. Jonnal, and K. Thorn, “Coherence gating and adaptive optics in the eye,” in Proceedings of The Coherence Domain Optical Methods and Optical Coherence Tomography in Biomedicine VII, vol. 4956 of Proceedings of SPIE, pp. 65–72, San Jose, Calif, USA, 2003.
[49]  J. M. Schmitt, S. H. Xiang, and K. M. Yung, “Speckle in optical coherence tomography,” Journal of Biomedical Optics, vol. 4, no. 1, pp. 95–105, 1999.
[50]  W. Drexler and J. G. Fujimoto, Optical Coherence Tomography: Technology and Applications, Springer, 2008.
[51]  M. S. Hrebesh, Y. Watanabe, and M. Sato, “Profilometry with compact single-shot low-coherence time-domain interferometery,” Optics Communications, vol. 281, no. 18, pp. 4566–4571, 2008.
[52]  M. S. Hrebesh, R. Dabu, Y. Watanabe, and M. Sato, “In vivo imaging of dynamic sample by real-time single-shot full- field optical coherence tomography,” Optics Communications, vol. 282, no. 4, pp. 674–683, 2009.
[53]  M. S. Hrebesh, Y. Watanabe, and M. Sato, “Spatial phase-shifting interferometer using paired wedge prism and combined wave plate,” Japanese Journal of Applied Physics, vol. 46, no. 15, pp. L369–L371, 2007.
[54]  D. Malakara, M. Servin, and Z. Malakara, Interferogram Analysis for Optical Testing, Marcel Dekker, New York, NY, USA, 1st edition, 1998.
[55]  J. E. Greiven-kamp and J. H. Bruning, Optical Shop Testing, D. Malacara Ed., John Wiley & Sons, New York, NY, USA, 2nd edition, 1992.
[56]  C. Koliopoulis, “Simultaneous phase shift interferometer,” in Advanced Optical Manufacturing and Testing II, vol. 1531 of Proceedings of SPIE, pp. 119–127, 1992.
[57]  R. Smythe and R. Moore, “Instantaneous phase measuring interferometry,” Optical Engineering, vol. 23, no. 4, pp. 361–364, 1984.
[58]  A. Asundi, L. Tong, and C. G. Boay, “Dynamic phase-shifting photoelasticity,” Applied Optics, vol. 40, no. 22, pp. 3654–3658, 2001.
[59]  N. B. E. Sawyer, S. P. Morgan, M. G. Somekh et al., “Wide field amplitude and phase confocal microscope with parallel phase stepping,” Review of Scientific Instruments, vol. 72, no. 10, pp. 3793–3801, 2001.
[60]  B. Barrientos, “Transient deformation measurement with ESPI using a diffractive optical element for spatial phase-stepping,” in Fringe, pp. 317–318, Akademie, 1997.
[61]  A. Hettwer, J. Kranz, and J. Schwider, “Three channel phase-shifting interferometer using polarization-optics and a diffraction grating,” Optical Engineering, vol. 39, no. 4, pp. 960–966, 2000.
[62]  J. E. Millerd and N. J. Brock, “Methods and apparatus for splitting imaging and measuring wavefronts in interferometry,” US Patent No. 6,304,330 and 6,522,808, 2001.
[63]  B. B. Garcia, A. J. Moore, C. Perez-Lopez, L. Wang, and T. Tschudi, “Spatial phase-stepped interferometry using a holographic optical element,” Optical Engineering, vol. 38, no. 12, pp. p2069–p2074, 1999.
[64]  B. Kimbrough, J. Millerd, J. Wyant, J. Hayes, M. North-Morris, and M. Novak, “Low-coherence vibration insensitive Fizeau interferometer,” in Proceedings of the Interferometry XIII, vol. 6292 of Proceedings of SPIE, p. 12, 2006.
[65]  K. L. Baker and E. A. Stappaerts, “A single-shot pixellated phase-shifting interferometer utilizing a liquid-crystal spatial light modulator,” Optics Letters, vol. 31, no. 6, pp. 733–735, 2006.
[66]  B. E. A. Saleh and M. C. Teich, Fundamentals of Photonics, John Wiley & Sons, New York, NY, USA, 1991.
[67]  M. Born and E. Wolf, Principles of Optics: Electromagnetic Theory of Propagation, Interference and Diffraction of Light, chapter 13, Pergamon, Oxford, UK, 5th edition, 1975.
[68]  T. W. Chad and G. Boxshall, Eds., Diaptomus Westwood, 1836, 2009.
[69]  J. W. Reid, Diaptomus Restripes, 1996.
[70]  D. Gabor, “Theory of communications,” Journal of the Institution of Electrical Engineers, vol. 93, pp. 429–457, 1947.
[71]  S. Lowenthal and Y. Belvaux, “Observation of phase objects by optically processed Hilbert transform,” Applied Physics Letters, vol. 11, no. 2, pp. 49–51, 1967.
[72]  H. Stark, “An extension of the Hilbert transform product theorem,” Proceedings of the IEEE, vol. 59, no. 9, pp. 1359–1360, 1971.
[73]  K. T. Eu and A. W. Lohmann, “Isotropic Hilbert spatial filtering,” Optics Communications, vol. 9, no. 3, pp. 257–262, 1973.
[74]  J. Ojeda-Castanada and E. Jara, “Isotropic Hilbert transform by anisotropic spatial filtering,” Applied Optics, vol. 25, no. 22, pp. 4035–4038, 1986.
[75]  E. Peli, “Hilbert transform pairs mechanisms,” Investigative Ophthalmology & Visual Science, vol. 30, ARVO Supplement, no. 3, p. 110, 1989.
[76]  A. W. Lohmann, E. Tepichin, and J. G. Ramirez, “Optical implementation of the fractional Hilbert transform for two-dimensional objects,” Applied Optics, vol. 36, no. 26, pp. 6620–6626, 1997.
[77]  Y. M. Zhu, F. Peyrin, and R. Goutte, “The use of a two-dimensional Hilbert transform for Wigner analysis of 2-dimensional real signals,” Signal Processing, vol. 19, no. 3, pp. 205–220, 1990.
[78]  S. L. Hahn, Hilbert Transforms in Signal Processing, Artech House, Norwood, Mass, USA, 1996.
[79]  J. P. Havlicek, J. W. Havlicek, and A. C. Bovik, “The analytic image,” in Proceedings of the IEEE International Conference on Image Processing, Santa Barbara, Calif, USA, 1997.
[80]  T. Bülow and G. Sommer, “A novel approach to the 2D analytic signal,” in Proceedings of the Computer Analysis of Images and Patterns (CAIP '99), Ljubljana, Slovenia, 1999.
[81]  T. Bülow, Hypercomplex spectral signal representations for the processing and analysis of images, Ph.D. thesis, Christian Albrechts University, 1999.
[82]  T. Bülow, “Hypercomplex spectral signal representations for the processing and analysis of images,” Tech. Rep. 9903, Christian-Albrechts-Universit?t zu Kiel, Institut für Informatik und Praktische Mathematik, 1999.
[83]  T. Bülow and G. Sommer, “Das Konzept einer zweidimensionalen Phase unter Verwendung einer algebraisch erweiterten Signalrepr?sentation,” in Mustererkennung, E. Paulus and F. M. Wahl, Eds., Tagungsband, 19. DAGM-Symposium, DAGM?97, pp. 351–358, Springer, 1997.
[84]  T. Bülow and G. Sommer, “Multi-dimensional signal processing using an algebraically extended signal representation,” in Algebraic Frames for the Perception and Action Cycle, G. Sommer and J. J. Koenderink, Eds., vol. 1315 of Lecture Notes in Computer Science, Workshop AFPAC?97, Kiel, pp. 148–163, Springer, Heidelberg, Germany, 1997.
[85]  T. A. Ell, “Quaternion-Fourier transforms for analysis of two-dimensional linear time-invariant partial differential systems,” in Proceedings of the 32nd IEEE Conference on Decision and Control, pp. 1830–1841, San Antonio, Tex, USA, 1993.

Full-Text

comments powered by Disqus

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133

WeChat 1538708413