Artificial-Intelligence-Based Techniques to Evaluate Switching Overvoltages during Power System Restoration

DOI: 10.1155/2013/316985

Full-Text   Cite this paper   Add to My Lib

Abstract:

This paper presents an approach to the study of switching overvoltages during power equipment energization. Switching action is one of the most important issues in the power system restoration schemes. This action may lead to overvoltages which can damage some equipment and delay power system restoration. In this work, switching overvoltages caused by power equipment energization are evaluated using artificial-neural-network- (ANN-) based approach. Both multilayer perceptron (MLP) trained with Levenberg-Marquardt (LM) algorithm and radial basis function (RBF) structure have been analyzed. In the cases of transformer and shunt reactor energization, the worst case of switching angle and remanent flux has been considered to reduce the number of required simulations for training ANN. Also, for achieving good generalization capability for developed ANN, equivalent parameters of the network are used as ANN inputs. Developed ANN is tested for a partial of 39-bus New England test system, and results show the effectiveness of the proposed method to evaluate switching overvoltages. 1. Introduction In recent years, due to economic competition and deregulation, power systems are being operated closer and closer to their limits. At the same time, power systems have increased in size and complexity. Both factors increase the risk of major power outages. After a blackout, power needs to be restored as quickly and reliably as possible, and, consequently, detailed restoration plans are nec [1–4]. One of the major concerns in power system restoration is the occurrence of overvoltages as a result of switching procedures. These can be classified as transient overvoltages, sustained overvoltages, harmonic resonance overvoltages, and overvoltages resulting from ferroresonance. Steady-state overvoltages occur at the receiving end of lightly loaded transmission lines as a consequence of line-charging currents (reactive power balance). Excessive sustained overvoltages may lead to damage of transformers and other power system equipment. Transient overvoltages are a consequence of switching operations on long transmission lines, or the switching of capacitive devices, and may result in arrester failures. Ferroresonance is a nonharmonic resonance characterized by overvoltages whose waveforms are highly distorted and can cause catastrophic equipment damages [1, 5]. Overvoltage will put the transformer into saturation, causing core heating and copious harmonic current generation. Circuit breaker called upon to operate during periods of high voltage will have reduced interrupting

References

[1]  M. M. Adibi, R. W. Alexander, and B. Avramovic, “Overvoltage control during restoration,” IEEE Transactions on Power Systems, vol. 7, no. 4, pp. 1464–1470, 1992.
[2]  A. Ketabi, A. M. Ranjbar, and R. Feuillet, “Analysis and control of temporary overvoltages for automated restoration planning,” IEEE Transactions on Power Delivery, vol. 17, no. 4, pp. 1121–1127, 2002.
[3]  S. A. Taher and I. Sadeghkhani, “Estimation of magnitude and time duration of temporary overvoltages using ANN in transmission lines during power system restoration,” Simulation Modelling Practice and Theory, vol. 18, no. 6, pp. 787–805, 2010.
[4]  A. Ketabi, I. Sadeghkhani, and R. Feuillet, “Using artificial neural network to analyze harmonic overvoltages during power system restoration,” European Transactions on Electrical Power, vol. 21, no. 7, pp. 1941–1953, 2011.
[5]  G. Morin, “Service restoration following a major failure on the hydro-quebec power system,” IEEE Transactions on Power Delivery, vol. 2, no. 2, pp. 454–463, 1987.
[6]  A. Ketabi, I. Sadeghkhani, and R. Feuillet, “Using artificial neural network to analyze harmonic overvoltages during power system restoration,” European Transactions on Electrical Power, vol. 21, no. 7, pp. 1941–1953, 2011.
[7]  D. Thukaram, H. P. Khincha, and S. Khandelwal, “Estimation of switching transient peak overvoltages during transmission line energization using artificial neural network,” Electric Power Systems Research, vol. 76, no. 4, pp. 259–269, 2006.
[8]  I. Sadeghkhani, A. Ketabi, and R. Feuillet, “Radial basis function neural network application to power system restoration studies,” Computational Intelligence and Neuroscience, vol. 2012, Article ID 654895, 2012.
[9]  G. Sybille, P. Brunelle, L. Hoang, L. A. Dessaint, and K. Al-Haddad, “Theory and applications of power system blockset, a MATLAB/Simulink-based simulation tool for power systems,” in Proceedings of IEEE Power Engineering Society Winter Meeting, pp. 774–779, 2000.
[10]  A. Ketabi and I. Sadeghkhani, Electric Power Systems Simulation Using MATLAB, Morsal Publications, 2011.
[11]  M. M. Duró, “Damping modelling in transformer energization studies for system restoration: some standard models compared to field measurements,” in Proceedings of IEEE Bucharest PowerTech: Innovative Ideas Toward the Electrical Grid of the Future, Bucharest, Romania, July 2009.
[12]  G. Sybille, M. M. Gavrilovic, J. Belanger, and V. Q. Do, “Transformer saturation effects on EHV system overvoltages,” IEEE Transactions on Power Apparatus and Systems, vol. 104, no. 3, pp. 671–680, 1985.
[13]  M. T. Hagan and M. B. Menhaj, “Training feedforward networks with the Marquardt algorithm,” IEEE Transactions on Neural Networks, vol. 5, no. 6, pp. 989–993, 1994.
[14]  A. Karami and M. S. Mohammadi, “Radial basis function neural network for power system load-flow,” International Journal of Electrical Power and Energy Systems, vol. 30, no. 1, pp. 60–66, 2008.
[15]  L. Prikler, G. Bán, and G. Bánfai, “EMTP models for simulation of shunt reactor switching transients,” International Journal of Electrical Power and Energy Systems, vol. 19, no. 4, pp. 235–240, 1997.
[16]  I. Sadeghkhani, A. Ketabi, and R. Feuillet, “Radial basis function neural network application to measurement and control of shunt reactor overvoltages based on analytical rules,” Mathematical Problems in Engineering, vol. 2012, Article ID 647305, 2012.
[17]  T. Keokhoungning, S. Premrudeepreechacharn, and K. Ngamsanroaj, “Evaluation of switching overvoltage in 500?kV transmission line interconnection Nam Theun 2 power plant to Roi Et 2 substation,” in Proceedings of the Asia-Pacific Power and Energy Engineering Conference (APPEEC '09), March 2009.
[18]  S. Wunderlich, M. M. Adibi, R. Fischl, and C. O. D. Nwankpa, “Approach to standing phase angle reduction,” IEEE Transactions on Power Systems, vol. 9, no. 1, pp. 470–478, 1994.

Full-Text

comments powered by Disqus

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133

WeChat 1538708413