Experiments on the Porch Swing Bearing of Michelson Interferometer for Low Resolution FTIR

DOI: 10.1155/2013/948638

Full-Text   Cite this paper   Add to My Lib

Abstract:

Porch swing bearing for the linear motion of the mirror in Michelson interferometer for mid-infrared low resolution Fourier transform spectrometer was studied experimentally using the modulation depth of the collimated laser beam. The mirror tilting was measured to be lower than 5 μrad over 3?mm mirror travel using two different bearings assemblies. Additionally, the manufacturing tolerances of the bearing type were proved to be loose enough not to limit the interferometer application. These demonstrate that the porch swing without any adjustment mechanisms provides the sufficient motion linearity. 1. Introduction Inexpensive and robust portable Fourier transform infrared (FTIR) spectrometers for gas analysers are still needed, because the existing solutions have some weaknesses like expenses, bulky size, or sensitivity to the temperature variations. The most sensitive component in FTIR spectrometer is the interferometer. We have aimed to design such an interferometer with 25?mm beam diameter and with 2?cm?1 resolution in the mid-infrared region. Numerous interferometer designs can be found, for example, from the papers by Jackson [1] and Kauppinen et al. [2] and from the book by Griffiths and de Haseth [3]. We have selected Michelson interferometer with plane mirrors, because it has only a few, even inexpensive, optical components. Using Michelson interferometer, it is possible to minimize the size and cost of the interferometer structure while keeping the beam diameter and the throughput constant. Additionally, we will not use any dynamic alignment of the optics which are commonly applied in most solutions. One of the key parameters in interferometer design is the modulation depth of the interferogram. In Michelson interferometer built using plane mirrors, the modulation depth is practically mainly affected by the tilting of optics which causes an angle between the output beams from interferometer. The shearing is the second major phenomenon determining the modulation depth. It is caused by the lateral shift of the output beams. With the plane mirror setup, the shearing is usually negligible because the plane mirrors do not shift the beams with each other. If the cube corners would be used as the end mirrors, the output beams would not tilt but they may be shifted with each other which would decrease the modulation depth especially when the size of the radiation source is finite. Maximizing the modulation depth sets the requirements for the movement of the mirror. The movable mirror has to remain parallel to the image of the second mirror formed by

References

[1]  R. R. Jackson, “Continuous scanning interferometers for mid-infrared spectrometry, chapter: Instrumentation for Mid- and Far-infrared Spectroscopy,” in Hand-Book of Vibrational Spectroscopy, J. M. Chalmers and P. R. Griffiths, Eds., vol. 1, pp. 264–282, John Wiley & Sons, 2002.
[2]  J. Kauppinen, J. Heinonen, and I. Kauppinen, “Interferometers based on the rational motion,” Applied Spectroscopy Reviews, vol. 39, no. 1, pp. 99–130, 2004.
[3]  P. R. Griffiths and J. A. de Haseth, Fourier Transform Infrared Spectrometry, John Wiley & Sons, 2nd edition, 2007.
[4]  D. R. Nohavec, L. S. Schwartz, and D. L. Trumper, “Super-Hybrid Magnetic Suspensions for Interferometric Scanners,” JSME International Journal Series C, vol. 40, no. 4, pp. 570–583, 1997.
[5]  H. Kobayashi, “Interferometric monitor for greenhouse gases (IMG)—project technical report,” Tech. Rep., IMG Mission Operation & Verification Committee CRIEPI, 1999.
[6]  R. P. Walker and J. D. Rex, “Interferometer design and data handling in a high vibration environment—part I: interferometer design,” in Multiplex and/or High-Throughput Spectroscopy, G. A. Vanasse, Ed., vol. 191 of Proceedings of SPIE, pp. 88–91, August 1979.
[7]  R. V. Jones, “Parallel and rectilinear spring movements,” Journal of Scientific Instruments, vol. 28, pp. 38–41, 1951.
[8]  G. W. Small, R. T. Kroutil, J. T. Ditillo, and W. R. Loerop, “Detection of atmospheric pollutants by direct analysis of passive fourier transform infrared interferograms,” Analytical Chemistry, vol. 60, no. 3, pp. 264–269, 1988.
[9]  R. J. Huppi, R. B. Shipley, and E. R. Huppi, “Balloon-borne fourier spectrometer using a focal plane detector array,” in Multiplex and/or High-Throughput Spectroscopy, G. A. Vanasse, Ed., vol. 191 of Proceedings of SPIE, pp. 26–32, August 1979.
[10]  J. C. Kemp and R. J. Huppi, “Rocket-borne cryogenic Michelson interferometer,” in Multiplex and/or High-Throughput Spectroscopy, G. A. Vanasse, Ed., vol. 191 of Proceedings of SPIE, pp. 135–142, August 1979.
[11]  R. A. Hanel, B. Schlacman, F. D. Clark et al., “The Nimbus III Michelson interferometer,” in Proceedings of the Aspen International Conference on Fourier Spectroscopy, G. A. Vanasse, A. S. Jn, and D. J. Baker, Eds., pp. 231–241, Air Force Cambridge Research Laboratories, Optical Physics Laboratory, United States Air Force, January 1971.
[12]  E. H. Wishnow, R. Wurtz, S. Blais-Ouellette et al., “Visible imaging Fourier transform spectrometer: design and calibration,” in Instrument Design and Performance for Optical/Infrared Ground-based Telescopes, M. Iye and A. F. M. Moorwood, Eds., vol. 4841 of Proceeding of SPIE, pp. 1067–1077, August 2002.
[13]  G. L. Auth, “Ruggedized compact interferometer requiring minimum isolation from mechanical vibrations,” US Patent 4,693,603, 1987.
[14]  D. R. Strait, “Moving mirror tilt adjust mechanism in an interferometer,” US Patent 4,991,961, February 1991.
[15]  R. F. Lacey, “Support for a moving mirror in an interferometer,” US Patent 4,710,001, December 1987.
[16]  G. R. Walker, “Precision frictionless flexure based linear translation mechanism insensitive to thermal and vibrational environments,” US Patent 6,836,968, 2005.
[17]  K. C. Schreiber, “Support for a movable mirror in an interferometer,” Patent Application Publication 2002/0149777, 2002.
[18]  T. V?likyl? and J. Kauppinen, “Modulation depth of Michelson interferometer with gaussian beam,” Applied Optics, vol. 50, pp. 6671–6677, 2011.
[19]  R. V. Jones and I. R. Young, “Some parasitic deflexions in parallel spring movements,” Journal of Scientific Instruments, vol. 33, no. 1, article 305, pp. 11–15, 1956.
[20]  Y. Muranaka, M. Inaba, T. Asano, and E. Furukawa, “Parasitic rotations in parallel spring movements,” Bulletin of the Japan Society of Precision Engineering, vol. 25, no. 3, pp. 208–213, 1991.
[21]  A. E. Hatheway, “Alignment of flexure stages for best rectilinear performance,” in Optomechanical and Precision Instrument Design, A. E. Hatheway, Ed., vol. 2542 of Proceedings of SPIE, pp. 70–80, July 1995.
[22]  A. E. Hatheway, “The kinetic center of the cantilever beam,” in Optomechanical Design and Precision Instruments, A. E. Hatheway, Ed., vol. 3132 of Proceedings of SPIE, pp. 218–222, 1997.
[23]  S. T. Smith, Flexures-Elements of Elastic Mechanisms, Gordon and Breach Science Publishers, 1st edition, 2000.
[24]  S. Awtar, Synthesis and analysis of parallel kinematic XY flexure mechanisms [Ph.D. thesis], Massachusetts Institute of Technology, 2003.
[25]  S. Awtar, A. H. Slocum, and E. Sevincer, “Characteristics of beam-based flexure modules,” Journal of Mechanical Design, Transactions of the ASME, vol. 129, no. 6, pp. 625–639, 2007.
[26]  E. Onillon, S. Henein, P. Theurillat, J. Krauss, and I. Kjelberg, “Interferometer scanning mirror mechanism,” in Mechatronic Systems 2002: A Proceedings Volume From the 2nd Ifac Conference, M. Tomizuka, Ed., Ifac Proceedings Series, International Federation of Automatic Control, Elsevier, 2003.
[27]  G. C. Auguson and N. O. Young, “A liquid-helium-cooled Michelson interferometer,” in Aspen International Conference on Fourier Spectroscopy, G. A. Vanasse, A. S. Jn, and D. J. Baker, Eds., pp. 281–288, Air Force Cambridge Research Laboratories, Optical Physics Laboratory, United States Air Force, January 1971.

Full-Text

comments powered by Disqus

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133

WeChat 1538708413