全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...

Titanium Alloy Stem as a Cause for Adverse Reaction to Metal Debris after Bipolar Hemiarthroplasty

DOI: 10.1155/2014/209461

Full-Text   Cite this paper   Add to My Lib

Abstract:

A 68-year-old male with failure of bipolar hemiarthroplasty consistent with adverse reaction to metal debris (ARMD) who presented with a painful cystic lesion and lower extremity swelling was encountered. However, revision surgical findings showed no apparent cause of ARMD previously described in the literature, such as corrosion at the head-neck junction and articular abrasion. Therefore, it was difficult to make a definite diagnosis of failure secondary to ARMD, which consequently led to the decision to perform two-stage revision procedure, though the stem was firmly fixed. Postoperative analysis in the retrieval tissues showed that the metal debris mainly originated from the titanium alloy stem itself. Although this is a very rare case, one should be aware that even the well-fixed femoral components themselves have the potential to be the cause of ARMD. 1. Introduction Numerous reports have described failures in hip arthroplasty secondary to adverse reaction to metal debris (ARMD), including osteolysis, metallosis, hypersensitivity reactions, aseptic lymphocyte-dominated vasculitis-associated lesions, cystic lesions, effusions, and pseudotumors [1, 2]. Additionally, there have been various literatures concerning the causes of ARMD. Metallosis has been suggested to occur as a result of either excessive liner wear up to the metal shell, liner breakage, impingement between the femoral neck and the acetabular component, or a combination of these elements [3–5]. Furthermore, numerous reports suggest corrosion at the head-neck junction or neck-stem junction as a cause [6–8]. Concerning the specific causes after hemiarthroplasty (HA), several case reports have been published describing massive metallosis caused by the abraded outer shell or trunnion corrosion in unipolar HA [9–11]. However, in this case, there was no apparent source of metal release previously described in the literature. Quantitative analysis of the metal in the specimens particularly played an important role in identifying the source of metal debris, which gave us new knowledge concerning ARMD. 2. Case Presentation A 68-year-old male with a right femoral neck fracture during bicycle touring underwent bipolar HA (VECTOR-Titan, Peter Brehm, Weisendorf, Germany) elsewhere. The early postoperative course had been excellent, and he was even able to go mountain climbing. Approximately 4 years later, he noticed severe pain especially in the anterior aspect of the right thigh with the onset of swelling in the right lower extremity, and he was referred to our institution for suspicion of

References

[1]  H. Pandit, S. Glyn-Jones, P. McLardy-Smith et al., “Pseudotumours associated with metal-on-metal hip resurfacings,” Journal of Bone and Joint Surgery B, vol. 90, no. 7, pp. 847–851, 2008.
[2]  D. J. Langton, S. S. Jameson, T. J. Joyce, N. J. Hallab, S. Natu, and A. V. F. Nargol, “Early failure of metal-on-metal bearings in hip resurfacing and large-diameter total hip replacement: a consequence of excess wear,” Journal of Bone and Joint Surgery B, vol. 92, no. 1, pp. 38–46, 2010.
[3]  M. Messieh, D. A. Mattingly, R. H. Turner, R. Scott, J. Fox, and J. Slater, “Wear debris from bipolar femoral neck-cup impingement: a cause of femoral stem loosening,” Journal of Arthroplasty, vol. 9, no. 1, pp. 89–93, 1994.
[4]  E. Onishi, H. Iida, K. Kawanabe, N. Ikeda, and T. Nakamura, “Severe metallosis caused by shaving down of the stem neck due to outer cup impingement of a bipolar endoprosthesis: a case report,” Bulletin of the Hospital for Joint Diseases, vol. 56, no. 4, pp. 214–217, 1997.
[5]  C. A. Cipriano, P. S. Issack, B. Beksac, A. G. Della Valle, T. P. Sculco, and E. A. Salvati, “Metallosis after metal-on-polyethylene total hip arthroplasty,” The American Journal of Orthopedics, vol. 37, no. 2, pp. E18–E25, 2008.
[6]  E. B. Mathiesen, J. U. Lindgren, G. G. A. Blomgren, and F. P. Reinholt, “Corrosion of modular hip prostheses,” Journal of Bone and Joint Surgery B, vol. 73, no. 4, pp. 569–575, 1991.
[7]  H. J. Cooper, C. J. Della Valle, R. A. Berger et al., “Corrosion at the head-neck taper as a cause for adverse local tissue reactions after total hip arthroplasty,” Journal of Bone and Joint Surgery A, vol. 94, no. 18, pp. 1655–1661, 2012.
[8]  I. P. S. Gill, J. Webb, K. Sloan, and R. J. Beaver, “Corrosion at the neck-stem junction as a cause of metal ion release and pseudotumour formation,” Journal of Bone and Joint Surgery B, vol. 94, no. 7, pp. 895–900, 2012.
[9]  M. Rizzo and T. B. Pace, “Premature failure of a hip hemiarthroplasty secondary to osteolysis and aseptic loosening,” The American Journal of Orthopedics, vol. 32, no. 4, pp. 206–209, 2003.
[10]  M. M. Khair, D. Nam, E. DiCarlo, and E. Su, “Aseptic lymphocyte dominated vasculitis-associated lesion resulting from trunnion corrosion in a cobalt-chrome unipolar hemiarthroplasty,” Journal of Arthroplasty, vol. 28, no. 1, pp. 196.e11–196.e14, 2013.
[11]  M. A. Mann, D. Tanzer, and M. Tanzer, “Severe metal-induced osteolysis many years after unipolar hip endoprosthesis,” Clinical Orthopaedics and Related Reseach, vol. 471, no. 7, pp. 2078–2082, 2013.
[12]  H. J. Agins, N. W. Alcock, M. Bansal et al., “Metallic wear in failed titanium-alloy total hip replacements. A histological and quantitative analysis,” Journal of Bone and Joint Surgery A, vol. 70, no. 3, pp. 347–356, 1988.
[13]  A. Grübl, C. Chiari, A. Giurea et al., “Cementless total hip arthroplasty with the rectangular titanium Zweymüller stem: a concise follow-up, at a minimum of fifteen years, of a previous report,” Journal of Bone and Joint Surgery A, vol. 88, no. 10, pp. 2210–2215, 2006.
[14]  M. Jasty, C. Bragdon, W. Jiranek, H. Chandler, W. Maloney, and W. H. Harris, “Etiology of osteolysis around porous-coated cementless total hip arthroplasties,” Clinical Orthopaedics and Related Research, no. 308, pp. 111–126, 1994.

Full-Text

Contact Us

[email protected]

QQ:3279437679

WhatsApp +8615387084133