A Conceptual Design Approach of Coupled Shear Walls

DOI: 10.1155/2013/161502

Full-Text   Cite this paper   Add to My Lib

Abstract:

Earthquake causes considerable damage to a large number of RCC high-rise buildings and tremendous loss of life. Therefore, designers and structural engineers should ensure to offer adequate earthquake resistant provisions with regard to planning, design, and detailing in high-rise buildings to withstand the effect of an earthquake and minimize disaster. As an earthquake resistant system, the use of coupled shear walls is one of the potential options in comparison with moment resistant frame (MRF) and shear wall frame combination systems in RCC high-rise buildings. Furthermore, it is reasonably well established that it is uneconomical to design a structure considering its linear behavior during earthquake. Hence, an alternative design philosophy needs to be evolved in the Indian context to consider the postyield behavior wherein the damage state is evaluated through deformation considerations. In the present context, therefore, performance-based seismic design (PBSD) has been considered to offer significantly improved solutions as compared to the conventional design based on linear response spectrum analysis. 1. Introduction The growth of population density and shortage of land in urban areas are two major problems for all developing countries including India. In order to mitigate these two problems, the designers resort to high-rise buildings, which are rapidly increasing in number, with various architectural configurations and ingenious use of structural materials. However, earthquakes are the most critical loading condition for all land based structures located in the seismically active regions. The Indian subcontinent is divided into different seismic zones as indicated by IS 1893 (Part 1) [1], facilitating the designer to provide adequate protection against earthquake. A recent earthquake in India on January 26th, 2001 caused considerable damage to a large number of RCC high-rise buildings (number of storey varies from 4 to 15) and tremendous loss of life. The reasons were (a) most of the buildings had soft and weak ground storey that provided open space for parking, (b) poor quality of concrete in columns, and (c) poor detailing of the structural design (http://www.nicee.org/eqe-iitk/uploads/EQR_Bhuj.pdf). Therefore, this particular incident has shown that designers and structural engineers should ensure to offer adequate earthquake resistant provisions with regard to planning, design, and detailing in high-rise buildings to withstand the effect of an earthquake to minimize disaster. As an earthquake resistant system, the use of coupled shear walls

References

[1]  Bureau of Indian Standards, “Criteria for earthquake resistant design of structures, part 1: general provisions and buildings,” Tech. Rep. IS-1893, part 1, Bureau of Indian Standards, New Delhi, India, 2002.
[2]  A. K. Jain, Reinforced Concrete Limit State Design, Nem Chand & Bros, Roorkee, India, 1999.
[3]  R. E. Englekirk, Seismic Design of Reinforced and Precast Concrete Buildings, John Wiley, New York, NY, USA, 2003.
[4]  R. Park and T. Paulay, Reinforced Concrete Structures, John Wiley & Sons, New York, NY, USA, 1975.
[5]  G. G. Penelis and A. J. Kappos, Earthquake-Resistant Concrete Structures, E&FN SPON, New York, NY, USA, 1997.
[6]  B. S. Smith and A. Coull, Tall Building Structures (Analysis and Design), John Wiley and Sons, New York, NY, USA, 1991.
[7]  P. J. Fortney and B. M. Shahrooz, “Boundary detailing of coupled core wall system wall piers,” Advances in Structural Engineering, vol. 12, no. 3, pp. 299–310, 2009.
[8]  K. A. Harries and D. S. McNeice, “Performance-based design of high-rise coupled wall systems,” Structural Design of Tall and Special Buildings, vol. 15, no. 3, pp. 289–306, 2006.
[9]  S. El-Tawil, K. A. Harries, P. J. Fortney, B. M. Shahrooz, and Y. Kurama, “Seismic design of hybrid coupled wall systems: state of the art,” Journal of Structural Engineering, vol. 122, no. 12, pp. 1453–1458, 2010.
[10]  T. Paulay and M. J. N. Priestley, Seismic Design of Reinforced Concrete and Masonry Buildings, John Wiley & Sons, New York, NY, USA, 1992.
[11]  F. Naiem, The Seismic Design Handbook, Kluwer Academic, Boston, Mass, USA, 2001.
[12]  Bureau of Indian Standards, “Earthquake resistant design and construction of buildings—code of practice,” Tech. Rep. IS-4326, Bureau of Indian Standards, New Delhi, India, 1993.
[13]  Bureau of Indian Standards, “Ductile detailing of reinforced concrete structures subjected to seismic forces—code of practice,” Tech. Rep. IS-13920, Bureau of Indian Standards, New Delhi, India, 1993.
[14]  Federal Emergency Management Agency, “NEHRP guidelines for the seismic rehabilitation of buildings,” Tech. Rep. FEMA-273, Federal Emergency Management Agency, Washington, DC, USA, 1997.
[15]  Federal Emergency Management Agency, “Prestandard and commentary for the seismic rehabilitation of buildings,” Tech. Rep. FEMA-356, Federal Emergency Management Agency, Washington, DC, USA, 2000.
[16]  Applied Technology Council, “Seismic evaluation and retrofit of concrete buildings,” Tech. Rep. ATC-40, Applied Technology Council, Redwood City, Calif, USA, 1996, Volume I.
[17]  L. Galano and A. Vignoli, “Seismic behavior of short coupling beams with different reinforcement layouts,” ACI Structural Journal, vol. 97, no. 6, pp. 876–885, 2000.
[18]  ATENA2D: Version 3.3.0.3, Nonlinear Finite Element Integrated Analysis, Cervenka Consulting, Praha, Czech Republic, 2006.
[19]  Bureau of Indian Standards, “Plain and reinforced concrete—code of practice,” Tech. Rep. IS-456, Bureau of Indian Standards, New Delhi, India, 2000.
[20]  Bureau of Indian Standards: IS-456, “Design aids for reinforced concrete,” Tech. Rep. SP-16, Bureau of Indian Standards, New Delhi, India, 1978.
[21]  V. Prakash, “Whither performance-based engineering in India?” ISET Journal, vol. 41, no. 1, pp. 201–222, 2004.
[22]  V. Prakash, G. H. Powell, and S. Campbell, DRAIN-3DX Base Program User Guide Version 1.10, Structural Engineering, Mechanics and Materials, Department of Civil Engineering UC, Berkeley, Calif, USA, 1993.
[23]  SAP2000: Advanced 10.0.5, Static and Dynamic Finite Element Analysis of Structures, Computers and Structures Inc., Berkeley, Calif, USA, 2006.
[24]  S. M. Pore, Performance Based Seismic Design of Low to Medium Rise RC Framed Buildings for India, Department of Earthquake Engineering, IIT Roorkee, Roorkee, India, 2007.
[25]  Canadian Standards Association, “Design of concrete structures for buildings,” CSA CAN3-A23. 3-M94, Canadian Standards Association, Rexdale, Canada, 1994.
[26]  American Institute of Steel Construction, Inc., Seismic Provisions for Structural Steel Buildings, American Institute of Steel Construction, Inc., Chicago, Ill, USA, 1997.
[27]  American Institute of Steel Construction, Inc., Seismic Provisions for Structural Steel Buildings, Supplement No. 2, American Institute of Steel Construction, Inc., Chicago, Ill, USA, 2000.
[28]  American Institute of Steel Construction, Inc., Seismic Provisions for Structural Steel Buildings, American Institute of Steel Construction, Inc., Chicago, Ill, USA, 2005.
[29]  T. Paulay, “The design of ductile reinforced concrete structural walls for earthquake resistance,” Earthquake Spectra, vol. 2, no. 4, pp. 783–823, 1986.
[30]  K. A. Harries, D. Mitchell, W. D. Cook, and R. G. Redwood, “Seismic response of steel beams coupling concrete walls,” Journal of Structural Engineering, vol. 119, no. 12, pp. 3611–3629, 1993.
[31]  T. Paulay, “A displacement-focused seismic design of mixed building systems,” Earthquake Spectra, vol. 18, no. 4, pp. 689–718, 2002.
[32]  T. Paulay, “The displacement capacity of reinforced concrete coupled walls,” Engineering Structures, vol. 24, no. 9, pp. 1165–1175, 2002.
[33]  R. A. Hindi and R. G. Sexsmith, “A proposed damage model for RC bridge columns under cyclic loading,” Earthquake Spectra, vol. 17, no. 2, pp. 261–281, 2001.
[34]  G. Xuan, B. M. Shahrooz, K. A. Harries, and G. A. Rassati, “A performance-based design approach for coupled core wall systems with diagonally reinforced concrete coupling beams,” Advances in Structural Engineering, vol. 11, no. 3, pp. 265–280, 2008.
[35]  S. Chao, K. Khandelwal, and S. El-Tawil, “Ductile web fracture initiation in steel shear links,” Journal of Structural Engineering, vol. 132, no. 8, pp. 1192–1200, 2006.
[36]  J. A. Munshi and S. K. Ghosh, “Displacement-based seismic design for coupled wall systems,” Earthquake Spectra, vol. 16, no. 3, pp. 621–642, 2000.
[37]  O. Chaallal, D. Gauthier, and P. Malenfant, “Classification methodology for coupled shear walls,” Journal of Structural Engineering, vol. 122, no. 12, pp. 1453–1458, 1996.
[38]  I. A. Macleod, Lateral Stiffness of Shear Walls with Openings, Department of Civil Engineering, Glasgow University, Glasgow, UK, 1966.
[39]  American Concrete Institute, “Building code requirements for reinforced concrete and commentary,” Tech. Rep. ACI 318-05/ACI 318R-05, American Concrete Institute, Farmington Hills, Mich, USA, 2005.
[40]  New Zealand Standard, “The design of concrete structures,” Tech. Rep. NZS, 3101 (part 1), New Zealand Standard, Wellington, New Zealand, 1995.

Full-Text

comments powered by Disqus

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133

WeChat 1538708413