Machines  2014 

Predictive Maintenance of Hydraulic Lifts through Lubricating Oil Analysis

DOI: 10.3390/machines2010001

Keywords: hydraulic oil, elevator, lift engine, metals, viscosity, total acid number

Full-Text   Cite this paper   Add to My Lib

Abstract:

This article examines the possibility of measuring lift maintenance through analysis of used hydraulic oil. Hydraulic oils have proved to be a reliable indicator for the maintenance performed on elevators. It has also been proved that the end users or the maintenance personnel do not always conform to the instructions of the elevators’ hydraulic machine manufacturer. Furthermore, by examining the proportion of the metals, an estimation of the corrosion and the wear resistance of the joined moving parts can be observed. Additionally, the presence of chlorine and calcium in hydraulic oils demonstrates their function in a highly corrosive environment.

References

[1]  Sander, R.J. White Paper: Reliable Hydraulic System Operation through Proper Fluid Selection & Maintenance, Lubrication Engineers, Inc. Available online: http://www.le-greece.gr/files/le-articles/2013%20Reliable%20Hydraulic%20System%20Operation%20white%20paper%20by%20John%20Sander.pdf (accessed on 22 August 2013).
[2]  Industrial Liquid Lubricants—ISO Viscosity Classification; ISO 3448:1992/Cor 1:1993; International Organization for Standardization: Geneva, Switzerland, 1993.
[3]  Standard Classification of Industrial Fluid Lubricants by Viscosity System; ASTM D2422, ASTM International: West Conshohocken, PA, USA, 2013. doi:10.1520/D2422.
[4]  Engine Oil Licensing and Certification System, Downstream Segment, API 1509, 17th ed. ed.; API Publishing Services: Washington, D.C., USA, 2012.
[5]  Borin, A.; Poppi, R.J. Application of mid infrared spectroscopy and iPLS for the quantification of contanminants in lubricating oil. Vib. Spectrosc. 2005, 37, 27–32, doi:10.1016/j.vibspec.2004.05.003.
[6]  Mang, T.; Dresel, W. Lubricants and Lubrication, 2nd ed. ed.; Wiley-VCH Verlag GmbH & Co. KGaA: Weinheim, Germany, 2007; pp. 274–337.
[7]  Chul, J.K.; Hyo, H.C.; Chae, H.S. Auto-ignition of lubricating oil working at high pressures in a compressor for an air conditioner. J. Hazard. Mater. 2011, 185, 416–422, doi:10.1016/j.jhazmat.2010.09.049.
[8]  Guan, L.; Feng, X.L.; Xiong, G.; Xie, J.A. Application of dielectric spectroscopy for engine lubricating oil degradation monitoring. Sens. Actuators A 2011, 168, 22–29, doi:10.1016/j.sna.2011.03.033.
[9]  Othmer, K. Encyclopedia of Chemical Technology, 3rd ed. ed.; Wiley: New York, NY, USA, 1980.
[10]  Michael, P.; Burgess, K.; Radle, E.; Wanke, T. An Investigation of Hydraulic Fluid Properties and Low-Speed Motor Efficiency. In Proceedings of the International Fluid Power Conference, Aachen, Germany, 22–24 March 2010; Volume 3, pp. 341–353.
[11]  Devin, M.T.; Michael, P. Boundary Lubrication and Fluid Thermal Properties and Low-Speed Motor Efficiency. In Proceedings of the STLE Annual MeetingSynthetics and Hydraulics II, Las Vegas, NV, USA, 19 May 2010; p. 108.
[12]  Vengudusamy, B.; Grafl, A.; Novotny-Farkas, F.; Schimmel, T.; Adam, K. Tribological behavior of antiwear additives used in hydraulic applications: Synergistic or antagonistic with other surface-active additives? Tribol. Int. 2013, 67, 199–210, doi:10.1016/j.triboint.2013.07.016.
[13]  Powell, J.R.; Campton, D.A.C. Automated FTIR Spectrometry for monitoring hydrocarbon based engine oils. Lubr. Eng. 1993, 49, 233–239.
[14]  Mcclelland, F.J.; Jones, W.R. FTIR photoacoustic spectrometry of diesel lubricating oils containing particulate matter. J. Soc. Tribol. Lubr. Eng. 2001, 57, 17–21.
[15]  Park, S.T.; Yang, B.S. An implementation of risk-based inspection for elevator maintenance. J. Mech. Sci. Technol. 2010, 24, 2367–2376, doi:10.1007/s12206-010-1004-1.
[16]  Kalligeros, S.S. The Necessity of Lift Inspections in Greece. Emerging Technologies in Non-Destructive Testing V. In Proceedings of the 5th Conference on Emerging Technologies in NDT, Ioannina, Greece, 19–21 September 2011; pp. 467–470.
[17]  ASTM D445-12 Standard Test Method for Kinematic Viscosity of Transparent and Opaque Liquids (and Calculation of Dynamic Viscosity). ASTM International: West Conshohocken, PA, USA, 2012. doi:10.1520/D0445-12.
[18]  ASTM D2270-10e1 Standard Practice for Calculating Viscosity Index From Kinematic Viscosity at 40 and 100 °C. ASTM International: West Conshohocken, PA, USA, 2012. doi:10.1520/D2270-10E01.
[19]  Tamson Instruments bv, Catalogue 2013–2014van’t Hoffstraat 12, 2665 JL, Bleiswijk, Netherlands. Available online: http://www.tamson.com (accessed on 22 August 2013).
[20]  ASTM D974-12 Standard Test Method for Acid and Base Number by Color-Indicator Titration. ASTM International: West Conshohocken, PA, USA, 2012. doi:10.1520/D0974-12.

Full-Text