Rare Earth Doped Silica Optical Fibre Sensors for Dosimetry in Medical and Technical Applications

DOI: 10.1155/2014/974584

Full-Text   Cite this paper   Add to My Lib

Abstract:

Radioluminescence optical fibre sensors are gaining importance since these devices are promising in several applications like high energy physics, particle tracking, real-time monitoring of radiation beams, and radioactive waste. Silica optical fibres play an important role thanks to their high radiation hardness. Moreover, rare earths may be incorporated to optimise the scintillation properties (emission spectrum, decay time) according to the particular application. This makes doped silica optical fibres a very versatile tool for the detection of ionizing radiation in many contexts. Among the fields of application of optical fibre sensors, radiation therapy represents a driving force for the research and development of new devices. In this review the recent progresses in the development of rare earth doped silica fibres for dosimetry in the medical field are described. After a general description of advantages and challenges for the use of optical fibre based dosimeter during radiation therapy treatment and diagnostic irradiations, the features of the incorporation of rare earths in the silica matrix in order to prepare radioluminescent optical fibre sensors are presented and discussed. In the last part of this paper, recent results obtained by using cerium, europium, and ytterbium doped silica optical fibres in radiation therapy applications are reviewed. 1. Introduction An optical fibre based dosimeter basically consists of a small scintillator coupled to a passive fibre of suitable length for remote signal transport to an optical detector (e.g., photomultiplier, photodiode, etc.). Such configuration has several advantages in radiation dosimetry applications. Indeed, the small volume of the detector makes the radiation field perturbation negligible, leading to high spatial resolution and point dose evaluations. These systems may enable a real-time measurement of the dose, providing a direct feedback to the medical physician during a radiation therapy (RT) treatment. In vivo measurements on patients take also advantage by the lack of any electrical supply. Furthermore, provided that a suitable scintillator material is used, an optical fibre based dosimeter is characterized by high sensitivity and reproducibility, independence of sensitivity upon accumulated dose, independence of the response from the environmental conditions, linearity of the response over a wide range of doses/dose rates, high radiation hardness, and nontoxicity for medical applications. However, for an effective use of these systems as dosimeters in RT, the stem effect, that is, the

References

[1]  C. J. Marckmann, M. C. Aznar, C. E. Andersen, and L. B?tter-Jensen, “Influence of the stem effect on radioluminescence signals from optical fibre Al2O3:C dosemeters,” Radiation Protection Dosimetry, vol. 119, no. 1–4, pp. 363–367, 2006.
[2]  I. Veronese, M. Fasoli, M. Martini et al., “Phosphorescence of SiO2 optical fibres doped with Ce3+ ions,” Physica Status Solidi (C) Current Topics in Solid State Physics, vol. 4, no. 3, pp. 1024–1027, 2007.
[3]  J. V. Jelley, Cerenkov Radiation and Its Applications, Pergamon Press, 1958.
[4]  A. S. Beddar, T. R. Mackie, and F. H. Attix, “Cerenkov light generated in optical fibres and other light pipes irradiated by electron beams,” Physics in Medicine and Biology, vol. 37, no. 4, pp. 925–935, 1992.
[5]  A. S. Beddar, T. R. Mckie, and F. H. Attix, “Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: I. Physical characteristics and theoretical considerations,” Physics in Medicine and Biology, vol. 37, no. 10, pp. 1883–1900, 1992.
[6]  S. F. de Boer, A. S. Beddar, and J. A. Rawlinson, “Optical filtering and spectral measurements of radiation-induced light in plastic scintillation dosimetry,” Physics in Medicine and Biology, vol. 38, no. 7, pp. 945–958, 1993.
[7]  D. Flühs, M. Heintz, F. Indenk?mpen, C. Wieczorek, H. Kolanoski, and U. Quast, “Direct reading measurement of absorbed dose with plastic scintillators—the general concept and applications to ophthalmic plaque dosimetry,” Medical Physics, vol. 23, no. 3, pp. 427–434, 1996.
[8]  D. Létourneau, J. Pouliot, and R. Roy, “Miniature scintillating detector for small field radiation therapy,” Medical Physics, vol. 26, no. 12, pp. 2555–2561, 1999.
[9]  S. Broggi, M. C. Cantone, A. Chiara et al., “Application of failure mode and effects analysis (FMEA) to pretreatment phases in tomotherapy,” Journal of Applied Clinical Medical Physics, vol. 14, no. 5, pp. 265–277, 2013.
[10]  M. C. Cantone, M. Ciocca, F. Dionisi et al., “Application of failure mode and effects analysis to treatment planning in scanned proton beam radiotherapy,” Radiation Oncology, vol. 8, no. 1, article 127, 2013.
[11]  M. Ciocca, M.-C. Cantone, I. Veronese et al., “Application of failure mode and effects analysis to intraoperative radiation therapy using mobile electron linear accelerators,” International Journal of Radiation Oncology Biology Physics, vol. 82, no. 2, pp. e305–e311, 2012.
[12]  P. Z. Y. Liu, N. Suchowerska, J. Lambert, P. Abolfathi, and D. R. McKenzie, “Plastic scintillation dosimetry: comparison of three solutions for the Cerenkov challenge,” Physics in Medicine and Biology, vol. 56, no. 18, pp. 5805–5821, 2011.
[13]  L. Archambault, L. Beaulieu, and S. A. Beddar, “Comment on ‘plastic scintillation dosimetry: comparison of three solutions for the Cerenkov challenge’,” Physics in Medicine and Biology, vol. 57, no. 11, pp. 3661–3665, 2012.
[14]  M. A. Clift, P. N. Johnston, and D. V. Webb, “A temporal method of avoiding the Cerenkov radiation generated in organic scintillator dosimeters by pulsed mega-voltage electron and photon beams,” Physics in Medicine and Biology, vol. 47, no. 8, pp. 1421–1433, 2002.
[15]  C. E. Andersen, S. M. S. Damkj?r, G. Kertzscher, S. Greilich, and M. C. Aznar, “Fiber-coupled radioluminescence dosimetry with saturated Al2O3:C crystals: characterization in 6 and 18 MV photon beams,” Radiation Measurements, vol. 46, no. 10, pp. 1090–1098, 2011.
[16]  J. M. Fontbonne, G. Iltis, G. Ban et al., “Scintillating fiber dosimeter for radiation therapy accelerator,” IEEE Transactions on Nuclear Science, vol. 49, no. 5, pp. 2223–2227, 2002.
[17]  A.-M. Frelin, J.-M. Fontbonne, G. Ban et al., “Spectral discrimination of ?erenkov radiation in scintillating dosimeters,” Medical Physics, vol. 32, no. 9, pp. 3000–3006, 2005.
[18]  M. Guillot, L. Gingras, L. Archambault, S. Beddar, and L. Beaulieu, “Spectral method for the correction of the Cerenkov light effect in plastic scintillation detectors: a comparison study of calibration procedures and validation in Cerenkov light-dominated situations,” Medical Physics, vol. 38, no. 4, pp. 2140–2150, 2011.
[19]  J. Lambert, Y. Yin, D. R. McKenzie, S. Law, and N. Suchowerska, “Cerenkov-free scintillation dosimetry in external beam radiotherapy with an air core light guide,” Physics in Medicine and Biology, vol. 53, no. 11, pp. 3071–3080, 2008.
[20]  J. Lambert, D. R. McKenzie, S. Law, J. Elsey, and N. Suchowerska, “A plastic scintillation dosimeter for high dose rate brachytherapy,” Physics in Medicine and Biology, vol. 51, no. 21, pp. 5505–5516, 2006.
[21]  M. Carrara, C. Cavatorta, M. Borroni et al., “Characterization of a Ce3+ doped SiO2 optical dosimeter for dose measurements in HDR brachytherapy,” Radiation Measurements, vol. 56, pp. 312–315, 2013.
[22]  M. Carrara, C. Tenconi, R. Guilizzoni et al., “Stem effect of a Ce3+ doped SiO2 optical dosimeter irradiated with a 192Ir HDR brachytherapy source,” Radiation Physics and Chemistry, vol. 104, pp. 175–179, 2014.
[23]  S. Buranurak, C. E. Andersen, A. R. Beierholm, and L. R. Lindvold, “Temperature variations as a source of uncertainty in medical fiber-coupled organic plastic scintillator dosimetry,” Radiation Measurements, vol. 56, pp. 307–311, 2013.
[24]  G. Kertzscher, C. E. Andersen, J. M. Edmund, and K. Tanderup, “Stem signal suppression in fiber-coupled Al2O3:C dosimetry for 192Ir brachytherapy,” Radiation Measurements, vol. 46, no. 12, pp. 2020–2024, 2011.
[25]  F. L. Galeener, G. Lucovsky, and R. H. Geils, “Raman and infrared spectra of vitreous As2O3,” Physical Review B, vol. 19, no. 8, pp. 4251–4258, 1979.
[26]  A. Pasquarello and R. Car, “Identification of Raman defect lines as signatures of ring structures in vitreous silica,” Physical Review Letters, vol. 80, no. 23, pp. 5145–5147, 1998.
[27]  C. A. Murray and T. J. Greytak, “Intrinsic surface phonons in amorphous silica,” Physical Review B, vol. 20, no. 8, pp. 3368–3387, 1979.
[28]  S. K. Sharma, J. F. Mammone, and M. F. Nicol, “Raman investigation of ring configurations in vitreous silica,” Nature, vol. 292, no. 5819, pp. 140–141, 1981.
[29]  A. Baraldi, R. Capelletti, N. Chiodini, et al., “Vibrational spectroscopy of OH-related groups in Ce3+- and Gd3+-doped silicate glasses,” Nuclear Instruments and Methods in Physics Research Section A, vol. 486, no. 1-2, pp. 408–411, 2002.
[30]  W. H. Weber, K. C. Hass, and J. R. McBride, “Raman study of CeO2: second-order scattering, lattice dynamics, and particle-size effects,” Physical Review B, vol. 48, article 178, 1993.
[31]  A. Vedda, N. Chiodini, D. Di Martino et al., “Ce3+-doped fibers for remote radiation dosimetry,” Applied Physics Letters, vol. 85, no. 26, pp. 6356–6358, 2004.
[32]  N. Caretto, N. Chiodini, F. Moretti, D. Origgi, G. Tosi, and A. Vedda, “Feasibility of dose assessment in radiological diagnostic equipments using Ce-doped radio-luminescent optical fibers,” Nuclear Instruments and Methods in Physics Research A: Accelerators, Spectrometers, Detectors and Associated Equipment, vol. 612, no. 2, pp. 407–411, 2010.
[33]  E. Mones, I. Veronese, F. Moretti et al., “Feasibility study for the use of Ce3+-doped optical fibres in radiotherapy,” Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, vol. 562, no. 1, pp. 449–455, 2006.
[34]  E. Mones, I. Veronese, A. Vedda et al., “Ce-doped optical fibre as radioluminescent dosimeter in radiotherapy,” Radiation Measurements, vol. 43, no. 2-6, pp. 888–892, 2008.
[35]  I. Veronese, M. C. Cantone, N. Chiodini et al., “Feasibility study for the use of cerium-doped silica fibres in proton therapy,” Radiation Measurements, vol. 45, no. 3–6, pp. 635–639, 2010.
[36]  I. Veronese, M. C. Cantone, M. Catalano et al., “Study of the radioluminesence spectra of doped silica optical fibre dosimeters for stem effect removal,” Journal of Physics D: Applied Physics, vol. 46, no. 1, Article ID 015101, 2013.
[37]  I. Veronese, M. C. Cantone, N. Chiodini et al., “The influence of the stem effect in Eu-doped silica optical fibres,” Radiation Measurements, vol. 56, pp. 316–319, 2013.
[38]  I. Veronese, M. C. Cantone, N. Chiodini et al., “Radioluminescence dosimetry by scintillating fiber optics: the open challenges,” in Hard X-Ray, Gamma-Ray and Neutron Detector Physics XV, vol. 8852 of Proceedings of SPIE, 88521L, August 2013.
[39]  I. Veronese, C. de Mattia, M. Fasoli et al., “Infrared luminescence for real time ionizing radiation detection,” Applied Physics Letters, vol. 105, no. 6, Article ID 061103, 2014.

Full-Text

comments powered by Disqus

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133