Abstract:

针对柔性直流架空输电线路频发的瞬时性直流故障,提出了模块化多电平改进子模块结构和混合级联拓扑以及MMC系统重合闸控制策略。新型子模块及混合级联结构具有直流故障自动闭锁和迅速恢复的能力,能进一步降低造价及损耗,并能继承已有成熟的控制方法。系统重合闸控制可以使柔性直流系统在小电流情况下判断直流故障是否消除并恢复系统运行,能有效应对永久性、瞬时性直流双极短路故障。文章构建了等效电路来分析直流双极短路故障及重合闸过程,并通过PSCAD/EMTDC仿真对所提方案进行了有效性验证。

References

[1]  Vrana T K,Torres-Olguin R E,Liu B,et al.The North Sea super grid:a technical perspective[C]//9 th IET International Conference on AC and DC Power Transmission.London:IET,2010:1-5.
[2]  汤广福.高压直流输电装备核心技术研发及工程化[J].电网技术,2012,36(1):1-6.Tang Guangfu.R&D and application of key technologies for HVDC equipment[J].Power System Technology,2012,36(1):1-6(in Chinese).
[3]  梁旭明,张平,常勇.高压直流输电技术现状及发展前景[J].电网技术,2012,36(4):1-9.Liang Xuming,Zhang Ping,Chang Yong.Recent advances in high-voltage direct-current power transmission and its developing potential[J].Power System Technology,2012,36(4):1-9(in Chinese).
[4]  殷自力,李庚银,李广凯,等.柔性直流输电系统运行机理分析及主回路相关参数设计[J].电网技术,2007,31(21):16-21.Yin Zili,Li Gengyin,Li Guangkai.Analysis on operational mechanism of VSC-HVDC and relevant parameter design of its main circuit[J].Power System Technology,2007,31(21):16-21(in Chinese).
[5]  Peftitsis D,Tolstoy G,Antonopoulos A,et al.High-power modular multilevel converters with SiC JFETs[J].IEEE Transactions on Power Electronics,2012,27(1):28-36.
[6]  吴俊宏,艾芊.多端柔性直流输电系统在风电场中的应用[J].电网技术,2009,33(4):22-27.W Junhong,Ai Qian.Research on multiterminal VSC-HVDC system for wind-farms[J].Power System Technology,2009,33(4):22-27(in Chinese).
[7]  Marquardt R.Modular multilevel converter:an universal concept for HVDC-networks and extended DC-bus-applications[C]//2010 International Power Electronics Conference (IPEC).Sapporo:IEEE,2010:502-507.
[8]  徐政,薛英林,张哲任.大容量架空线柔性直流输电关键技术及前景展望[J].中国电机工程学报,2014,34(29):5051-5062.Xu Zheng,Xue Yinglin,Zhang Zheren.VSC-HVDC technology suitable for bulk power overhead line transmission [J].Proceedings of the CSEE,2014,34(29):5051-5062(in Chinese).
[9]  薛英林,徐政.C-MMC直流故障穿越机理及改进拓扑方案[J].中国电机工程学报,2013,33(21):63-70.Xue Yinglin,Xu Zheng.DC fault ride-through mechanism and improved topology scheme of C-MMC[J].Proceedings of the CSEE,2013,33(21):63-70(in Chinese).
[10]  Candelaria J,Jae-Do Park.VSC-HVDC system protection:a review of current methods[C]//Power Systems Conference and Exposition (PSCE),2011 IEEE/PES.Phoenix,AZ:IEEE,2011:1-7.
[11]  Franck C M.HVDC circuit breakers:a review identifying future research needs[J].IEEE Transactions on Power Delivery,2011,26(2):998-1007.
[12]  Marquardt R.Modular multilevel converter topologies with DC-Short circuit current limitation[C]//Power Electronics and ECCE Asia (ICPE & ECCE),2011 IEEE 8 th International Conference on.Jeju:IEEE,2011:1425-1431.
[13]  郑占锋,邹积岩,董恩源,等.直流开断与直流断路器[J].高压电器,2006(6):445-449.Zheng Zhanfeng,Zou Jiyan,Dong Enyuan,et al.DC interruption and DC circuit breaker[J].High Voltage Apparatus,2006(6):445-449(in Chinese).
[14]  魏晓光,高冲,罗湘,等.柔性直流输电网用新型高压直流断路器设计方案[J].电力系统自动化,2013,37(15):95-102.Wei Xiaoguang,Gao Chong,Luo Xiang.A novel design of high- voltage DC circuit breaker in HVDC flexible transmission grid[J].Automation of Electric Power Systems,2013,37(15):95-102(in Chinese).
[15]  Bucher M K,Jacobson B.Proactive hybrid HVDC breakers:a key innovation for reliable HVDC grids[C]//Integrating Supergrids and Microgrids International Symposium.Bologna,Italy:CIGRE,2011:1-8.
[16]  Bucher M K,Walter M M,Pfeiffer M,et al.Options for ground fault clearance in HVDC offshore networks[C]//Energy Conversion Congress and Exposition (ECCE),2012 IEEE.Raleigh,NC:IEEE,2012:2880-2887.
[17]  Li Xiaoqian,Song Qiang,Liu Wenhua,et al.Protection of nonpermanent faults on DC overhead lines in MMC-based HVDC systems[J].IEEE Transactions on Power Delivery,2013,28(1):483-490.
[18]  Cui Shenghui,Sungmin Kim,Jae-Jung Jung,et al.Principle,control and comparison of modular multilevel converters (MMCs) with DC short circuit fault ride-through capability[C]//Applied Power Electronics Conference and Exposition (APEC),2014 Twenty-Ninth Annual IEEE.Fort Worth,TX:IEEE,2014:610-616.
[19]  Tang G,Xu Z,Zhou Y.Impacts of three MMC-HVDC configurations on AC system stability under DC line faults[J].IEEE Transactions on Power Systems,2014,29(6):3030-3040.
[20]  敬华兵,年晓红.新型的模块化多电平换流器子模块保护策略[J].电网技术,2013,37(7):1954-1958.Jing Huabing,Nian Xiaohong.A novel protection strategy for sub-modules of modularized multi-level converter[J].Power System Technology,2013,37(7):1954-1958(in Chinese).
[21]  Merlin M M C,Green T C,Mitcheson P D,et al.A new hybrid multi-level voltage-source converter with DC fault blocking capability//9th IET International Conference on AC and DC Power Transmission,2010.London:IET,2010:1-5.
[22]  Schmitt D,Wang Y,Weyh T,et al.DC-side fault current management in extended multiterminal-HVDC-grids[C]//2012 9th International Multi-Conference on Systems,Signals and Devices (SSD).Chemnitz:IEEE,2012:1-5.
[23]  Marquardt R.Modular multilevel converter topologies with DC-short circuit current limitation[C]//2011 IEEE 8 th International Conference on Power Electronics and ECCE Asia (ICPE & ECCE).Jeju:IEEE,2011:1425-1431.
[24]  丁云芝,苏建徽,周建.基于钳位双子模块的MMC故障清除和重启能力分析[J].电力系统自动化,2014,38(1):97-103.Ding Yunzhi,Su Jianhui,Zhou Jian.Function-integrated design of load shedding implementation station and automatic switchover based on stability control platform[J].Automation of Electric Power Systems,2014,38(1):97-103(in Chinese).
[25]  王姗姗,周孝信,汤广福,等.模块化多电平换流器HVDC直流双极短路子模块过电流分析[J].中国电机工程学报,2011,31(1):1-7.Wang Shanshan,Zhou Xiaoxin,Tang Guangfu,et al.Analysis of submodule overcurrent caused by DC pole-to-pole fault in modular multilevel converter HVDC system[J].Proceedings of the CSEE,2011,31(1):1-7(in Chinese).
[26]  王姗姗,周孝信,汤广福,等.模块化多电平HVDC输电系统子模块电容值的选取和计算[J].电网技术,2011,31(1):26-32.Wang Shanshan,Zhou Xiaoxin,Tang Guangfu,et al.Selection and calculation for sub-module capacitance in modular multi-level converter HVDC power transmission system[J].Power System Technology,2011,31(1):26-32(in Chinese).

Full-Text

comments powered by Disqus

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133

WeChat 1538708413