5. Habijan T, Glogowski T, Kuhn S, et al. Can human mesenchymal stem cells survive on a NiTi implant material subjected to cyclic loading? Acta Biomater, 2011, 7(6): 2733-2739.
9. Bogdanski D, K?ller M, Müller D, et al. Easy assessment of the biocompatibility of Ni-Ti alloys by in vitro cell culture experiments on a functionally graded Ni-NiTi-Ti material[J]. Biomaterials. 2002, 23(23): 4549-4555.
[8]
10. El Medawar L, Rocher P, Hornez JC, et al. Electrochemical and cytocompatibility assessment of NiTiNOL memory shape alloy for orthodontic use. Biomol Eng, 2002, 19(2-6): 153-160.
[9]
11. Wever DJ, Elstrodt JA, Veldhuizen AG, et al. Scoliosis correction with shape-memory metal: results of an experimental study. Eur Spine J, 2002, 11(2): 100-106.
[10]
12. Olson JL, Velez-Montoya R, Erlanger M. Ocular biocompatibility of nitinol intraocular clips. Invest Ophthalmol Vis Sci, 2012, 53(1): 354-360.
24. Thierry B, Tabrizian M, Trepanier C, et al. Effect of surface treatment and sterilization processes on the corrosion behavior of NiTi shape memory alloy. J Biomed Mater Res, 2000, 51(4): 685-693.
[15]
29. Kapanen A, Kinnunen A, Ryh?nen J, et al. TGF-beta1 secretion of ROS-17/2.8 cultures on NiTi implant material. Biomaterials, 2002, 23(16): 3341-3346.
33. K?hl M, Habijan T, Bram M, et al. Powder metallurgical near-net-shape fabrication of porous NiTi shape memory alloys for use as long-term implants by the combination of the metal injection molding process with the space-holder technique. Advanced Engineering Materials, 2009, 11(12): 959-968.
[20]
34. Wu S, Liu X, Wu G, et al. Wear mechanism and tribological characteristics of porous NiTi shape memory alloy for bone scaffold. J Biomed Mater Res A, 2013, 101(9): 2586-2601.
[21]
2. Leitner T, Sabirov I, Pippan R, et al. The effect of severe grain refinement on the damage tolerance of a superelastic NiTi shape memory alloy. J Mech Behav Biomed Mater, 2017, 71: 337-348.
15. Assad M, Yahia LH, Rivard CH, et al. In vitro biocompatibility assessment of a nickel-titanium alloy using electron microscopy in situ end-labeling (EM-ISEL). J Biomed Mater Res, 1998, 41(1): 154-161.
[26]
18. 李慧萍. Cr离子注入镍钛合金的表面改性研究. 北京: 北方工业大学, 2014.
[27]
19. Dudek K, Goryczka T. Electrophoretic deposition and characterization of thin hydroxyapatite coatings formed on the surface of NiTi shape memory alloy. Ceramics International, 2016, 42(16): 19124-19132.
[28]
21. 朱姿虹. NiTi合金表面无镍层及生物改性层制备与表征. 镇江: 江苏大学, 2016.
[29]
22. Choi J, Bogdanski D, K?ller M, et al. Calcium phosphate coating of nickel-titanium shape-memory alloys. Coating procedure and adherence of leukocytes and platelets. Biomaterials, 2003, 24(21): 3689-3696.
[30]
23. Chu CL, Guo C, Sheng XB, et al. Microstructure, nickel suppression and mechanical characteristics of electropolished and photoelectrocatalytically oxidized biomedical nickel titanium shape memory alloy. Acta Biomater, 2009, 5(6): 2238-2245.
[31]
25. Trépanier C, Tabrizian M, Yahia LH, et al. Effect of modification of oxide layer on NiTi stent corrosion resistance. J Biomed Mater Res, 1998, 43(4): 433-440.
[32]
26. Armitage DA, Parker TL, Grant DM. Biocompatibility and hemocompatibility of surface-modified NiTi alloys. J Biomed Mater Res A, 2003, 66(1): 129-137.
[33]
27. Xu JL, Zhong ZC, Yu DZ, et al. Effect of micro-arc oxidation surface modification on the properties of the NiTi shape memory alloy. J Mater Sci Mater Med, 2012, 23(12): 2839-2846.
[34]
28. Kobayashi S, Ohgoe Y, Ozeki K, et al. Dissolution effect and cytotoxicity of diamond-like carbon coatings on orthodontic archwires. J Mater Sci Mater Med, 2007, 18(12): 2263-2268.