-  2018 

Measurement of Magnetic Field Intensity within Captain Elechi Amadi Polytechnic Rumuola, Rivers State, Nigeria

Full-Text   Cite this paper   Add to My Lib

Abstract:

The measurement of magnetic field intensity within Captain Elechi Amadi Polytechnic, Rumuola was carried out with the aid of a handheld Bentech (GM-3120) Model Electromagnetic Radiation Metre. A total of 6 sampled locations were recorded; randomly with six distinct measurement and their coordinates at each of the sampled location with the aid of the global system position satellite (GPS) device. The measurement took place between 2017 November to 2018 March. A minimum value of 0.3417 ± 0.65 μT was recorded at the Administrative Block and a maximum value of 1.9767 ± 1.43 μT at the Business Centre. The overall mean values of all the sampled locations all fall below the recommended limit for the outdoor magnetic field intensity exposure of 100 μT of the International Commission of Non-Ionizing Radiation Protection (ICNIRP). The outcome of the measurement reveals that the exposure to magnetic field intensity to staffs, students and commercial workers within the campus of the Captain Elechi Amadi Polytechnic poses no health hazard.