Test Gas Generation from Pure Liquids: An Application-Oriented Overview of Methods in a Nutshell

DOI: 10.1155/2012/417029

Full-Text   Cite this paper   Add to My Lib

Abstract:

The generation of test gas from pure liquids has a wide variety of applications in laboratory and field experiments, for which the quality of the test gas is of significance. Therefore, various methods for test gas generation have been designed. Each method has unique advantages and disadvantages. Thus, a short overview is presented within the scope of this paper. Furthermore, a common bubbler system is presented, which was built to generate test gas from volatile organic compounds for experimental usage in laboratory applications. An analysis is conducted with respect to the generated concentrations at different temperatures and flow rates of the diluting gas. Accuracy and stability of this method are investigated. 1. Introduction The generation of test gas from pure liquids, for example, volatile organic compounds (VOCs), is of great importance for laboratory and field experiments. There are several major applications for it:(i)Adsorption analysis of isotherms, breakthrough, and kinetics.(ii)Standard gas for calibration of analytical instruments, for example, gas chromatography (GC).(iii)Safety system verification/calibration.(iv)Calibration of air quality analysis and pollution control systems.(v)Chemical vapour deposition (CVD). Various methods have been developed for the generation of test gas. They can be divided into two categories: static and dynamic methods [1–4]. The injection of liquid and its evaporation in an enclosed container with defined volume of diluting gas constitute the functional principles of all static methods. The metal, glass, or plastic container could be employed without any other complex apparatus, which is simple and inexpensive. However, one of the crucial drawbacks of these methods is the appearance of adsorption and condensation on the wall of the container [2]. Therefore, the concentration of the test gas cannot be reliable at higher concentrations. Another drawback is that only a limited amount of test gas is generated once. Moreover, leakages and pressure changes exert an effect. Compared with static methods, dynamic methods are based on a continuous diluting gas flow through the generation system and the mixture with the vapour at a known generation rate [2]. Though these methods are more complex and expensive, but they show important advantages, such as a negligible effect of the adsorption and condensation at the state of equilibrium, continuous test gas generation without volume limit, continuous dilution providing a wide concentration range, and possible control of test gas condition for temperature, relative

References

[1]  P. Konieczka, J. Namiesnik, and J. F. Biernat, “Generation of standard gaseous mixtures by thermal decomposition of surface compounds. standard mixtures of thiols,” Journal of Chromatography, vol. 540, no. 1-2, pp. 449–455, 1991.
[2]  J. Namie?nik, “Generation of standard gaseous mixtures,” Journal of Chromatography A, vol. 300, pp. 79–108, 1984.
[3]  J. A. Koziel, P. A. Martos, and J. Pawliszyn, “System for the generation of standard gas mixtures of volatile and semi-volatile organic compounds for calibrations of solid-phase microextraction and other sampling devices,” Journal of Chromatography A, vol. 1025, no. 1, pp. 3–9, 2004.
[4]  R. S. Barratt, “The preparation of standard gas mixtures: a review,” Analyst, vol. 106, no. 1265, pp. 817–849, 1981.
[5]  G. O. Nelson and K. S. Griggs, “Precision dynamic method for producing known concentrations of gas and solvent vapor in air,” Review of Scientific Instruments, vol. 39, no. 6, pp. 927–928, 1968.
[6]  G. O. Nelson, Controlled Test Atmospheres, Principles and Techniques, Ann Arbor Science Publishers, Ann Arbor, MI, USA, 1971.
[7]  S. Tumbiolo, L. Vincent, J. F. Gal, and P. C. Maria, “Thermogravimetric calibration of permeation tubes used for the preparation of gas standards for air pollution analysis,” Analyst, vol. 130, no. 10, pp. 1369–1374, 2005.
[8]  J. P. Spinhirne and J. A. Koziel, “Generation and calibration of standard gas mixtures for volatile fatty acids using permeation tubes and solid-phase microextraction,” American Society of Agricultural Engineers, vol. 46, no. 6, pp. 1639–1646, 2003.
[9]  D. Helmig, T. Revermann, J. Pollmann et al., “Calibration system and analytical considerations for quantitative sesquiterpene measurements in air,” Journal of Chromatography A, vol. 1002, no. 1-2, pp. 193–211, 2003.
[10]  G. O. Nelson, Gas Mixtures: Preparation and Control, CRC Press, Boca Raton, FL, USA, 1992.
[11]  J. M. McKelvey and H. E. Hoelscher, “Apparatus for preparation of very dilute gas mixtures,” Analytical Chemistry, vol. 29, no. 1, p. 123, 1957.
[12]  A. Naganowska-Nowak, P. Konieczka, A. Przyjazny, and J. Namie?nik, “Development of techniques of generation of gaseous standard mixtures,” Critical Reviews in Analytical Chemistry, vol. 35, no. 1, pp. 31–55, 2005.
[13]  E. E. Campbell, M. F. Milligan, and H. M. Miller, “Evaluation of methods for the determination of halogenated hydrocarbons in air,” American Industrial Hygiene Association Journal, vol. 20, no. 2, pp. 138–141, 1959.
[14]  H. Hori and Y. Yanagisawa, “A new vapor generator of multicomponent organic solvents using capillary effect,” Environmental Science and Technology, vol. 27, no. 10, pp. 2023–2030, 1993.
[15]  D. J. Troy, “Measurement of atmospheric pollution by ultraviolet photometry,” Analytical Chemistry, vol. 27, no. 8, pp. 1217–1221, 1955.
[16]  P. P. Ballesta, A. Baldan, and J. Cancelinha, “Atmosphere generation system for the preparation of ambient air volatile organic compound standard mixtures,” Analytical Chemistry, vol. 71, no. 11, pp. 2241–2245, 1999.
[17]  D. Knopf, “Continuous dynamic-gravimetric preparation of calibration gas mixtures for air pollution measurements,” Accreditation and Quality Assurance, vol. 6, no. 3, pp. 113–119, 2001.
[18]  P. C. Maria, J. F. Gal, M. Balza, E. Peré-Trepat, and S. Tumbiolo, “Using thermogravimetry for weight loss monitoring of permeation tubes used for generation of trace concentration gas standards,” Analytical Chemistry, vol. 74, no. 1, pp. 305–307, 2002.
[19]  M. Gautrois and R. Koppmann, “Diffusion technique for the production of gas standards for atmospheric measurements,” Journal of Chromatography A, vol. 848, no. 1-2, pp. 239–249, 1999.
[20]  G. Xiong and J. Pawliszyn, “Microwave-assisted generation of standard gas mixtures,” Analytical Chemistry, vol. 74, no. 10, pp. 2446–2449, 2002.
[21]  E. Przyk, P. Konieczka, J. Szczygelska-Tao, R. Teschner, J. F. Biernat, and J. Namie?nik, “Use of porous glass and silica gel as support media of a surface compound for generation of analytes in gaseous standard mixtures. A new method for the determination of the amount of analyte generated,” Journal of Chromatography A, vol. 928, no. 1, pp. 99–108, 2001.
[22]  CEM Liquid Delivery System, “Bronkhorst High-Tech B.V.,” http://www.bronkhorst.com/files/downloads/brochures/cem.pdf.
[23]  R. H. Perry, D. W. Green, and J. O. Maloney, Perry’s Chemical Engineers Handbook, McGraw-Hill, New York, NY, USA, 6th edition, 1984.

Full-Text

Contact Us

[email protected]

QQ:3279437679

WhatsApp +8615387084133