全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...
-  2019 

Bicuspid aortic valve repair adapted to aortic phenotype

DOI: 10.21037/acs.2019.04.13

Keywords: Bicuspid aortic valve (BAV), aortic repair, ring annuloplasty

Full-Text   Cite this paper   Add to My Lib

Abstract:

The bicuspid aortic valve (BAV) is the most common congenital cardiovascular anomaly and may present with differing phenotypes including almost constant annular dilation. We have developed a standardized approach to BAV repair with a systematic adjunct of aortic annuloplasty according to the three phenotypes of the proximal aorta, which include a dilated aortic root, dilated ascending aorta and normal root and ascending aorta. In our cohort of 191 patients, freedom from AV-related re-intervention was 98% for remodeling with annuloplasty (n=100) and 100% for tubular aortic replacement with annuloplasty (n=31) at 8 years. In an isolated aortic insufficiency (AI) group, freedom from AV-related re-intervention varied from 72.4% with a single subvalvular annuloplasty ring (n=31) compared to 100% at 6 years when a double sub- and supra-valvular (STJ) annuloplasty ring was performed (n=29). Restoration of the annulus: sinotubular junction (STJ) ratio is a key factor to ensure longevity of the bicuspid valve repair and freedom from re-intervention