全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...
-  2019 

Coronary physiology assessment in a?cardiac transplant patient

DOI: 10.1007/s12471-019-1300-z

Full-Text   Cite this paper   Add to My Lib

Abstract:

A 39-year-old male underwent coronary angiography 14 years after cardiac allograft transplantation revealing an intermediate grade stenosis in the mid left anterior descending artery (LAD) for which further physiological assessment was performed (Fig. 1). Subsequent pressure wire-based fraction flow reserve (FFRpw) was 0.87, suggesting a hemodynamically non-significant lesion. However, non-hyperaemic 3?dimensional quantitative coronary angiography-based vessel fractional flow reserve (vFFR) was 0.74 (Fig. 1b). Given the discrepancies, optical coherence tomography was performed showing a fibrofatty plaque with a minimal lumen area (MLA) of 1.70mm2. The LAD was subsequently treated with a 3.0?×?15?mm stent. There has been ongoing debate on the validity of using FFR in denervated hearts due to high rates of microvascular dysfunction and an unreliable hyperaemic response [1]. Angiography based vFFR might be a promising new technology to study the hemodynamic significance of intermediate coronary artery lesions in denervated hearts [2]