全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...
-  2019 

Falsely decreased ferritin concentrations in two patients with haemophagocytic lymphohistiocytosis: A case report

DOI: 10.1177/0004563218793166

Keywords: High-dose hook,prozone,ferritin,haemophagocytic lymphohistiocytosis

Full-Text   Cite this paper   Add to My Lib

Abstract:

The high-dose hook effect, or prozone effect, can lead to negative or falsely lowered plasma ferritin results. Here, cases of a 16-year-old boy and a 70-year-old woman with haemophagocytic lymphohystiocytosis with extremely high concentrations of plasma ferritin (387,000?μg/L and 138,000?μg/L, respectively) are presented. In both cases, falsely lowered ferritin results were reported without any analyser flag. This article emphasizes the importance of recognition of the high-dose hook effect, since a watertight solution is lacking

Full-Text

Contact Us

[email protected]

QQ:3279437679

WhatsApp +8615387084133