全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...
-  2019 

Combined Conventional and Amplitude

DOI: 10.1177/0883073819829256

Keywords: electroencephalography (EEG),neonatal neurology,neurocritical care,newborn,diagnostic accuracy

Full-Text   Cite this paper   Add to My Lib

Abstract:

Seizure monitoring via amplitude-integrated EEG is standard of care in many neonatal intensive care units; however, conventional EEG is the gold standard for seizure detection. We compared the diagnostic yield of amplitude-integrated EEG interpreted at the bedside, amplitude-integrated EEG interpreted by an expert, and conventional EEG. Neonates requiring seizure monitoring received amplitude-integrated EEG and conventional EEG in parallel. Clinical events and amplitude-integrated EEG were interpreted at bedside. Subsequently, amplitude-integrated EEG and conventional EEG were independently analyzed by experienced neonatology and neurology readers. Sensitivity and specificity of bedside amplitude-integrated EEG as compared to expert amplitude-integrated EEG interpretation and conventional EEG were evaluated. Thirteen neonates were monitored for an average duration of 33 hours (range 15-94, SD 25). Fourteen seizure-like events were detected by clinical observation, and 12 others by bedside amplitude-integrated EEG analysis. One of the clinical, and none of the bedside amplitude-integrated EEG events were confirmed as seizures on conventional EEG. Post hoc expert amplitude-integrated EEG interpretation revealed eight suspected seizures, all different from the ones detected by the bedside amplitude-integrated EEG team, of which one was confirmed via conventional EEG. Eight seizures were recorded on conventional EEG. Expert amplitude-integrated EEG interpretation had a sensitivity of 13% with 46% specificity for individual seizure detection, and a sensitivity of 50% with 46% specificity for detecting patients with seizures. Real-world bedside amplitude-integrated EEG monitoring failed to detect all seizures evidenced via conventional EEG, while misclassifying other events as seizures. Even post hoc expert amplitude-integrated EEG interpretation provided limited sensitivity and specificity. Considering the poor sensitivity and specificity of bedside amplitude-integrated EEG interpretation, combined monitoring may provide limited clinical benefit

Full-Text

comments powered by Disqus

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133

WeChat 1538708413