全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...
-  2019 

Predictive value of routine point

DOI: 10.1177/2048872617745893

Keywords: Acute myocardial infarction,prehospital triage/methods,cardiac troponin,emergency medical services,point-of-care

Full-Text   Cite this paper   Add to My Lib

Abstract:

The purpose of this study was to determine the predictive value of routine prehospital point-of-care cardiac troponin T measurement for diagnosis and risk stratification of patients with suspected acute myocardial infarction. All prehospital emergency medical service vehicles in the Central Denmark Region were equipped with a point-of-care cardiac troponin T device (Roche Cobas h232) for routine use in all patients with a suspected acute myocardial infarction. During the study period, 1 June 2012–30 November 2015, prehospital point-of-care cardiac troponin T measurements were performed in a total of 19,615 cases seen by the emergency medical service and 18,712 point-of-care cardiac troponin T measurements in 15,781 individuals were matched with an admission. A final diagnosis of acute myocardial infarction was confirmed in 2187 cases and a total of 2150 point-of-care cardiac troponin T measurements (11.0%) had a value ≥50 ng/l, including 966 with acute myocardial infarction (sensitivity: 44.2%, specificity: 92.8%). Patients presenting with a prehospital point-of-care cardiac troponin T value ≥50 ng/l had a one-year mortality of 24% compared with 4.8% in those with values <50 ng/l, log-rank: p<0.001. The following variables showed the strongest association with mortality in multivariable analysis: point-of-care cardiac troponin T≥50 ng/l (hazard ratio 2.10, 95% confidence interval: 1.90–2.33), congestive heart failure (hazard ratio 1.93, 95% confidence interval: 1.74–2.14), diabetes mellitus (hazard ratio 1.42, 95% confidence interval: 1.27–1.59) and age, one-year increase (hazard ratio 1.08, 95% confidence interval: 1.08–1.09). Patients with suspected acute myocardial infarction and a prehospital point-of-care cardiac troponin T ≥50 ng/l have a poor prognosis irrespective of the final diagnosis. Routine troponin measurement in the prehospital setting has a high predictive value and can be used to identify high-risk patients even before hospital arrival so that they may be re-routed directly for advanced care at an invasive centre

Full-Text

comments powered by Disqus

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133

WeChat 1538708413