Simple Measurement of Carbon Films on Copper Tubes and Their Effects on Corrosion

DOI: 10.4236/ojcm.2021.111002, PP. 12-22

Keywords: Copper Tube, Residual Carbon, Pitting Corrosion, Cooling Water System, Re-frigerator, XPS

Full-Text   Cite this paper   Add to My Lib

Abstract:

It has been reported that pitting corrosion in copper tubes occurs due to the effect of a carbon film produced by the influence of undergoing an oil and heat treatment. As a quantitative method for determining the residual carbon amount, it has been reported that the inner surface of a copper tube can be dissolved with a mixed acid to collect and analyze the adhering carbon; however, this method is dangerous and difficult. Therefore, two methods were examined as a simple quantitative method for obtaining the residual carbon amount using copper tubes with known residual carbon amounts. One method utilizes X-ray photoelectron spectroscopy (XPS), and the other method utilizes the potential difference between the carbon film-adhered surface and carbon film-removed surface. In regard to XPS measurement, a linear correlation was found between the spectral intensity of C and the residual carbon amount; therefore, XPS measurements were considered to be effective as a simple measurement method for the carbon film on the inner surface of a copper tube. In the evaluation method by measuring the corrosion potential, a correlation was observed between the potential difference ΔE and the residual carbon amount of the inner surface of the tube and the outer surface of the polished tube. It is considered possible to estimate the residual carbon amount from the prepared calibration curve. Through these studies, it is suggested that the carbon film was non-uniformly present on the surface of the copper tube. Therefore, the galvanic current was measured, and the effect of a non-uniform carbon film on corrosion behavior was investigated. As a result, in the measurement of galvanic current, the current flowed from the copper tube with a large amount of residual carbon (cathode) to the copper tube with a small amount of residual carbon (anode). In addition, the higher the area ratio of the carbon film was, the larger the galvanic current tended to be.

References

[1]  Notoya, T. (2008) Corrosion Resistance and Corrosion of Copper. Rust Prevention & Control Japan, 1, 25-32.
[2]  Cornwall, F.J., Wildsmith, G. and Gilbert, P.T. (1976) Pitting Corrosion in Copper Tubes in Cold Water Service. ASTM STP, 576, 155-179.
https://doi.org/10.1520/STP41404S
[3]  Yamada, Y., Mizutani, K. and Inoue, Y. (2014) Development of Corrosion Protection Research for Copper Tube over the Last Few Decades and Future Prospects. Zairyo-to-Kankyo, 63, 158-162.
[4]  Yamada, Y. (2019) Development of Corrosion Protection Research for Copper Tube in Recent Years and Future Prospects. Refrigeration, 94, 73-77.
[5]  Iyasu, T., Toyokawa, K., Kuratani, M., Ikeda, I., Tanaka, N., Yamada, Y. and Sakurada, O. (2020) Field Evaluation of New Water Treatment Chemical against Type I” Pitting Corrosion of Copper Tube. Journal of Japan Institute of Copper, 59, 115-119.
[6]  Iyasu, T., Kuratani, M., Ikeda, I., Tanaka, N., Yamada, Y. and Sakurada, O. (2020) A Study of Water Treatment Chemical Effects on Type I” Pitting Corrosion of Copper Tubes. Materials Sciences and Applications, 11, 494-504.
https://doi.org/10.4236/msa.2020.117034
[7]  Yamada, Y., Mori, A., Hatanaka, R., Atsumi T. and Nakao, N. (1998) Pitting Corrosion of Copper Coiled Tubes in the Air Conditioning System Having the Open Heat Storage Water Tank. Zairyo-to-Kankyo, 47, 723-728.
https://doi.org/10.3323/jcorr1991.47.723
[8]  Sakai, M., Seri, O., Yamada, Y., Toda, I. and Iitsuka, M. (2002) Effect of Residual Carbon Deposits on Corrosion Behavior of Copper Tube Filled with Water. Zairyo-to-Kankyo, 51, 12-16.
https://doi.org/10.3323/jcorr1991.51.12
[9]  Yamanaka, H., Nagai, T., Nonaka, H., Tsuchiya, H. and Fujimoto, S. (2020) Effect of Deposits on Corrosion of Copper Tubes in a Circulating Cooling Water System. Zairyo-to-Kankyo, 69, 17-25.
https://doi.org/10.3323/jcorr.69.17