Smart Grid  2021 

考虑直流电网关键设备的限流电抗优化配置方法
Optimal Configuration Method of Reactor Considering the Key Equipment in DC Grid

DOI: 10.12677/SG.2021.111006, PP. 47-57

Keywords: 直流电网,能量吸收,故障限流器,动作时序,优化配置
DC Power Grid
, Energy Absorption, Fault Current Limiter, Action Sequence, Optimized Configuration

Full-Text   Cite this paper   Add to My Lib

Abstract:

直流电网故障快速清除是保证电网持续可靠运行的关键。平波电抗器、故障限流器和混合式断路器等设备可使故障电流发展速度得以削弱,同时,他们对故障电流发展特性也有一定影响,需要进一步研究使平波电抗和故障限流器配置更合理。首先研究了多种限流设备的共同限流下,综合考虑故障限流器的能量吸收及断路器的动作时序,给出了直流电网故障电流计算方法。其次,将减小断路器开断电流和限流设备吸收能量作为优化目标,得到了直流电抗参数配置的优化方法。最后在PSCAD/EMTDC进行仿真验证,结果表明所提优化方法比之前优化方法降低故障开断电流15%。
The rapid clearing of DC faults is the key to ensuring the continuous operation of the grid. Equipments such as Current Limited Reactor (CLR), Fault-Current-Limiter (FCL) and hybrid DCCB can weaken the development speed of fault current. At the same time, they also have influence on the development characteristics of fault current. Further research is needed to make the configuration of CLR and FCL more reasonable. Firstly, the current calculation method of DC grid is given considering the energy absorption of FCL and the action sequence of DCCB. Secondly, taking the breaking current of DCCB and the energy absorbed by current limiting equipment as optimization targets, the optimization method of the DC reactance is obtained. Finally, PSCAD/EMTDC simulation verified that the proposed optimization method reduces the fault breaking current by 15% compared with the previous optimization method.

References

[1]  杨艳晨, 郭剑波, 王姗姗, 王铁柱, 李英彪, 赵兵, 吴广禄. 柔性直流电网直流过电压分析及控制策略研究[J]. 电网技术, 2019, 43(5): 1586-1592. http://dx.chinadoi.cn/10.13335/j.1000-3673.pst.2018.0588
[2]  孔明, 邱宇峰, 贺之渊, 何维国, 刘隽. 模块化多电平式柔性直流输电换流器的预充电控制策略[J]. 电网技术, 2011, 35(11): 67-73.
[3]  吴俊宏, 艾芊. 多端柔性直流输电系统在风电场中的应用[J]. 电网技术, 2009, 33(4): 22-27.
[4]  姚良忠, 吴婧, 王志冰, 李琰, 鲁宗相. 未来高压直流电网发展形态分析[J]. 中国电机工程学报, 2014(34): 6007-6020.
[5]  刘泽洪, 郭贤珊. 含新能源接入的双极柔性直流电网运行特性研究与工程实践[J]. 电网技术, 2020, 44(9): 3595-3603. http://dx.chinadoi.cn/10.13335/j.1000-3673.pst.2020.0254a
[6]  赵成勇, 宋冰倩, 许建中. 柔性直流电网故障电流主动控制典型方案综述[J]. 电力系统自动化, 2020, 44(5): 3-13. http://dx.chinadoi.cn/10.7500/AEPS20190626003
[7]  Leterme, W., Beerten, J. and Van Hertem, D. (2016) Equivalent Circuit for Half-Bridge MMC dc Fault Current Contribution. 2016 IEEE International Energy Conference (ENERGYCON), Leuven, 4-8 April 2016, 1-6.
https://doi.org/10.1109/ENERGYCON.2016.7513914
[8]  Callavik, M., Blomberg, A., H?fner, J. and Jacobson, B. (2012) The Hybrid HVDC Breaker An Innovation Breakthrough Enabling Reliable HVDC Grids. ABB Grid System, Technical Paper, 361, 143-152.
[9]  Lin, W. and Jovcic, D. (2014) LCL and L-VSC Converters with DC Fault Current-Limiting Property and Minimal Power Losses. IEEE Transactions on Power Delivery, 29, 2359-2368.
https://doi.org/10.1109/TPWRD.2014.2314481
[10]  Deng, F. and Chen, Z. (2013) Design of Protective Inductors for HVDC Transmission Line within DC Grid Offshore Wind Farms. IEEE Transactions on Power Delivery, 28, 75-83.
https://doi.org/10.1109/TPWRD.2012.2224384
[11]  杨汾艳, 徐政. 直流输电系统平波电抗器电感参数的选择研究[J]. 高压电器, 2009, 45(3): 8-10+14.
[12]  孙帮新. 特高压直流系统中平波电抗器配置方案[J]. 电工技术, 2009(11): 6-7+40.
[13]  Kontos, E., Rodrigues, S., Pinto, R.T. and Bauer, P. (2014) Optimization of Limiting Reactors Design for DC Fault Protection of Multi-Terminal HVDC Networks. 2014 IEEE Energy Conversion Congress & Exposition, Pittsburgh, 14-18 September 2014, 5347-5354.
https://doi.org/10.1109/ECCE.2014.6954134
[14]  李岩, 龚雁峰. 多端直流电网限流电抗器的优化设计方案[J]. 电力系统自动化, 2018, 42(23): 120-128. http://dx.chinadoi.cn/10.7500/AEPS20180308009
[15]  王守相, 禚程程, 刘琪, 杨景刚, 陈庆. 基于VSC的直流配电网限流电抗器位置和参数优化配置方法[J]. 电力自动化设备, 2019, 39(12): 89-95. http://dx.chinadoi.cn/10.16081/j.epae.201911030
[16]  朱思丞, 赵成勇, 李承昱, 许建中. 考虑故障限流器动作的直流电网限流电抗器优化配置[J]. 电力系统自动化, 2018, 42(15): 142-149+281-283. http://dx.chinadoi.cn/10.7500/AEPS20180308007
[17]  李国庆, 边竞, 王鹤, 孙云鹤, 王振浩. 考虑直流电抗器的电容型限流器特性及优化配置[J]. 电力系统自动化, 2020, 44(5):23-29+234-241. http://dx.chinadoi.cn/10.7500/AEPS20190607003
[18]  Lee, H.Y., Mansoor, A., Park, K.H. and Lee, B.-W. (2018) Feasible Application Study of Several Types of Superconducting Fault Current Limiters in HVDC Grids. IEEE Transactions on Applied Superconductivity, 28, Article No. 5601205.
https://doi.org/10.1109/TASC.2018.2799745
[19]  Font, A., Ilhan, S. and Ozdemir, A. (2016) Line Surge Arrester Application for a 380 kV Power Transmission Line. 2016 IEEE International Conference on High Voltage Engineering & Application, Chengdu, 19-22 September 2016, 1-4.
https://doi.org/10.1109/ICHVE.2016.7800722
[20]  Li, C.Y., Zhao, C.Y., Xu, J.Z., Ji, Y.K., Zhang, F. and An, T. (2017) A Pole-to-Pole Short-Circuit Fault Current Calculation Method for DC Grids. IEEE Transactions on Power Systems, 32, 4943-4953.
https://doi.org/10.1109/TPWRS.2017.2682110