Dosimetric Comparison: Volumetric Modulated Arc Therapy (VMAT) and 3D Conformal Radiotherapy (3D-CRT) in High Grade Glioma Cancer—Experience of Casablanca Cancer Center at the Cheikh Khalifa International University Hospital
Background: Intensity Modulated Radiation Therapy (IMRT) is currently employed as a
major arm of treatment in multiforme glioblastoma (GBM). The present study
aimed to compare 3D-CRT with IMRT to assess tumor volume coverage and OAR
sparing for the treatment of malignant
gliomas. Materialsandmethods: We assessed 22 anonymized
patients datasets with High Grade Glioblastoma who had undergone post-operative Intensity
Modulated Radiotherapy (IMRT) and 3D Conformal Radiotherapy (3D-CRT), This
study will compare and contrast treatment plans Rapidarc and 3D-CRT to
determine which technology improves
significantly dosimetric parameters. Results: Plans will be assessed by
reviewing the coverage of the PTV using mean, maximum and minimum doses while
the OAR doses will be compared using the maximal doses for each, as set out in
the QUANTEC dose limits. Conclusion: The use of IMRT seems a superior
technique as compared to 3D-CRT for the treatment of malignant gliomas having
the potential to increase the dose to the PTV while sparing OARs optimally.
References
[1]
Chan, M.F., Schupak, K., Burman, C., Chui, C.S. and Ling, C.C. (2003) Comparison of Intensity Modulated Radiotherapy with Three-Dimensional Conformal Radiation Therapy Planning for Glioblas-Toma Multiforme. Medical Dosimetry, 28, 261-265. https://doi.org/10.1016/j.meddos.2003.08.004
[2]
Narayana, A., Yamada, J., Berry, S., Shah, P., Hunt, M., Gutin, P.H. and Leibel, S.A. (2006) Intensity-Modulated Radiotherapy in High-Grade Gliomas: Clinical and Dosimetrical Results. International Journal of Radiation Oncology, Biology, Physics, 64, 892-897. https://doi.org/10.1016/j.ijrobp.2005.05.067
[3]
Thilmann, C., Zabel, A., Grosser, K.H., Hoess, A., Wannenmacher, M. and Debus, J. (2001) Intensity-Modulated Radiotherapy with an Integrated Boost to the Macroscopic Tumor Volume in the Treatment of High-Grade Gliomas. International Journal of Cancer, 96, 341-349. https://doi.org/10.1002/ijc.1042
[4]
Piroth, M.D., Pinkawa, M., Holy, R., Stoffels, G., Demirel, C., Attieh, C., Kaiser, H.J., Langen, K.J. and Eble, M.J. (2009) Integrated-Boost IMRT or 3-D-CRT Using FET-PET Based Auto-Contoured Target Volume Delineation for Glioblastoma Multiforme—A Dosimetric Comparison. Radiation Oncology, 4, Article No. 57.
https://doi.org/10.1186/1748-717X-4-57
[5]
Chan, M.F., Schupak, K., Burman, C., et al. (2003) Comparison of Intensity-Modulated Radiotherapy with Three-Dimensional Conformal Radiation Therapy Planning for Glioblastoma Multiforme. Medical Dosimetry, 28, 261-265.
https://doi.org/10.1016/j.meddos.2003.08.004
[6]
MacDonald, S.M., Ahmad, S., Kachris, S., Vogds, B.J., DeRouen, M., Gittleman, A.E., DeWyngaert, K. and Vlachaki, M.T. (2007) Intensity Modulated Radiation Therapy Versus Three-Dimensional Conformal Radiation Therapy for the Treatment of High Grade Glioma: A Dosimetric Comparison. Journal of Applied Clinical Medical Physics, 8, 47-60. https://doi.org/10.1120/jacmp.v8i2.2423
[7]
Zach, L., Stall, B., Ning, H., Ondos J., Arora B., Uma, S., Miller, R.W., Citrin, D., Camphausen, K.A. (2009) Dosimetric Comparison of Four Treatment Planning Methods for High Grade Glioma. Radiation Oncology, 4, Article No. 45.
https://doi.org/10.1186/1748-717X-4-45
[8]
Wagner, D., Christiansen, H., Wolff, H., Vorwerk, H. (2009) Radiotherapy of Malignant Gliomas: Comparison of Volumetric Single Arc Technique (RapidArc), Dynamic Intensity-Modulated Technique and 3D Conformal Technique. Radiother Oncol, 93, 593-596. https://doi.org/10.1016/j.radonc.2009.10.002