Optimal Placement of Distribution Generation Sources in Hybrid Generation Network

DOI: 10.4236/sgre.2021.125005, PP. 65-80

Keywords: Distribution Generators, Renewable Integration, Optimal Allocation, Particle Swarm Optimization

Full-Text   Cite this paper   Add to My Lib

Abstract:

The ideal places and size of the distribution generators were determined by reducing the loss of power in the distribution networks. The ideal positioning of various kinds of DGs has been suggested in the current job. In this job, the ideal power factor for DG supply has been acquired, both the active power as well as the reactive power. In the proposed approach, different types of distribution generation (DG) supply both reactive and real power. For the optimal placement of DG sources, particle swarm optimization techniques have been used in this job. Each of these innovations has its own strengths and drawbacks. Most of the methods that have been proposed so far to formulate DG’s optimum placement problem only consider Type-I DGs, Type-II and Type-III DGs that are considered for optimal position in the existing research. In the reference, artificial bee colony algorithm was used to determine sites of DGs and condenser combinations and optimal size. The author used PSO method in the reference to determine the appropriate positioning of the DG’s and to maximize the savings of power loss and voltage profile in the distribution network.

References

[1]  CIGRE (2018) Impact of Increasing Contribution of Dispersed Generation on the Power System. Working Group 37.23.
[2]  EL-Khattam, W. and Salama, M.M.A. (2018) Distributed System Planning Using Distributed Generation. Proceeding of IEEE Canadian Conference on Electrical and Computer Engineering, Vol. 1, 579-582.
[3]  Akhtar, I., Paul, W.U.H., Kirmani, S. and Asim, M. (2021) Cost Analysis of 18 kW Solar Photovoltaic System for Smart Cities Growth in India. In: Iqbal, A., Malik, H., Riyaz, A., Abdellah, K. and Bayhan, S., Eds., Renewable Power for Sustainable Growth, Lecture Notes in Electrical Engineering, Vol. 723, Springer, Singapore, 661-667.
https://doi.org/10.1007/978-981-33-4080-0_63
[4]  Kumar, V., Kumar, R., Gupta, I. and Gupta, H.O. (2017) DG Integrated Approach for Service Restoration under Cold Load Pickup. IEEE Transactions on Power Delivery, 25, 398-406.
https://doi.org/10.1109/TPWRD.2009.2033969
[5]  Kim, J.O., Nam, S.W., Park, S.K. and Singh, C. (2013) Dispersed Generation Planning Using Improved Hereford Ranch Algorithm. Electric Power Systems Research, 47, 47-55.
https://doi.org/10.1016/S0378-7796(98)00038-8
[6]  Zhang, D., Fu, Z. and Zhang, L. (2007) An Improved TS Algorithm for Loss Minimum Reconfiguration in Large-Scale Distribution Systems. Electric Power Systems Research, 77, 685-694.
https://doi.org/10.1016/j.epsr.2006.06.005
[7]  Kansal, S., Kumar, V. and Taygi, B. (2012) Composite Active and Reactive Power Compensation of Distribution Networks. 7th IEEE International Conference on Industrial and Information Systems, Chennai, 6-9 August 2012, 1-6.
https://doi.org/10.1109/ICIInfS.2012.6304764
[8]  Sajjadi, S.M., Haghifam, M.R. and Salehi, J. (2013) Simultaneous Placement of Distributed Generation and Capacitors in Distribution Networks Considering Voltage Stability Index. International Journal of Electrical Power & Energy Systems, 46, 366-375.
https://doi.org/10.1016/j.ijepes.2012.10.027
[9]  Prommee, W. and Ongsakul, W. (2011) Optimal Multiple Distributed Generation Placement in Microgrid System by Improved Reinitialized Social Structures Particle Swarm Optimization. European Transactions on Electrical Power, 21, 489.
https://doi.org/10.1002/etep.456
[10]  Su, C.T., Chang, C.F. and Chiou, J.P. (2005) Distribution Network Reconfiguration for Loss Reduction by Ant Colony Search Algorithm. Electric Power Systems Research, 75, 190-199.
https://doi.org/10.1016/j.epsr.2005.03.002
[11]  Griffin, Tomsovic, K., Secrest, D. and Law, A. (2000) Placement of Dispersed Generation Systems for Reduced Losses. Proceedings of 33rd Annual Hawaii International Conference on System Sciences, Maui, 4-7 January 2000, 1-9.
[12]  Wang, C. and Nehrir, M.H. (2004) Analytical Approaches for Optimal Placement of DG Sources in Power Systems. IEEE Transactions on Power Systems, 4, 2068-2076.
https://doi.org/10.1109/TPWRS.2004.836189
[13]  Acharya, N., Mahat, P. and Mithulananthan, N. (2006) An Analytical Approach for DG Allocation in Primary Distribution Network. International Journal of Electrical Power & Energy Systems, 28, 669-678.
https://doi.org/10.1016/j.ijepes.2006.02.013
[14]  Gozel, T. and Hocaoglu, M.H. (2009) An Analytical Method for the Sizing and Sitting of Distributed Generators in Radial Systems. Electric Power Systems Research, 79, 912-918.
https://doi.org/10.1016/j.epsr.2008.12.007
[15]  Paul, W.U.H., Bhat, M.B., Kirmani, S. and Nahvi, S.A. (2020) Data Based Controller Design for PMDC Motor Setup Using System Identification. Studies in Indian Place Names, 40, 11.
[16]  Hung, D.Q., Mithulananthan, N. and Bansal, R.C. (2010) Analytical Expressions for DG Allocation in Primary Distribution Networks. The IEEE Transactions on Energy Conversion, 25, 814-820.
https://doi.org/10.1109/TEC.2010.2044414
[17]  Abu-Mouti, F.S. and El-Hawary, M.E. (2011) Heuristic Curve-Fitted Technique for Distributed Generation Optimization in Radial Distribution Feeder Systems. IET Generation, Transmission & Distribution, 5, 172-180.
https://doi.org/10.1049/iet-gtd.2009.0739
[18]  Schmill, J.V. (1965) Optimum Size and Location of Shunt Capacitors on Distribution Feeders. IEEE Transactions on Power Apparatus and Systems, 84, 825-832.
https://doi.org/10.1109/TPAS.1965.4766262
[19]  Masoum, M.A.S., Ladjevardi, M., Jafarian, A. and Fuchs, E.F. (2004) Optimal Placement, Replacement, and Sizing of Capacitor Banks in Distorted Distribution Networks by Genetic Algorithms. IEEE Transactions on Power Delivery, 19, 1794-1801.
https://doi.org/10.1109/TPWRD.2004.835438
[20]  Gallego, R.A., Monticelli, A.J. and Romero, R. (2001) Optimal Capacitor Placement in Radial Distribution Networks. IEEE Transactions on Power Delivery, 16, 630-637.
https://doi.org/10.1109/59.962407
[21]  Abu-Mouti, F.S. and El-Hawary, M.E. (2011) Optimal Distributed Generation Allocation and Sizing in Distribution Systems via Artificial Bee Colony Algorithm. IEEE Transactions on Power Delivery, 26, 2090-2101.
https://doi.org/10.1109/TPWRD.2011.2158246
[22]  Singh, S.P. and Rao, A.R. (2012) Optimal Allocation of Capacitors in Distribution Systems Using Particle Swarm Optimization. International Journal of Electrical Power & Energy Systems, 43, 1267-1275.
https://doi.org/10.1016/j.ijepes.2012.06.059
[23]  Elgerd, I.O. (1971) Electric Energy System Theory—An Introduction. McGraw-Hill, New York.
[24]  Eberhart, R.C. and Shi, Y. (2000) Comparing Inertial Weights and Constriction Factor in Particle Swarm Optimization. Proceedings of the 2000 Congress on Evolutionary Computation. CEC00 (Cat. No.00TH8512), 1, 84-88.
[25]  Kashem, M.A., Ganapathy, V., Jasmon, G.B. and Buhari, M.I. (2000) A Novel Method for Loss Minimization in Distribution Networks. Proceedings of International Conference on Electric Utility Deregulation and Restructuring and Power Technology, London, 4-7 April 2000, 251-256.
[26]  Baran, M.E. and Wu, F.F. (1989) Optimal Capacitor Placement on Radial Distribution Systems. IEEE Transactions on Power Delivery, 4, 725-734.
https://doi.org/10.1109/61.19265