In the present work, a treatment technique for trigeminal neuralgia (TN)
using LINAC radiosurgery is shown. The technique is based on the optimization
of ten static arcs in such a way as to minimize the overlapping of the
treatment fields with the brainstem. We will call this technique
brainstem-optimized (BO). The results are compared with another technique
described in the literature known as a virtual cone (VC). The
comparison of dosimetry results that havebeen carried out essentially shows that the doses in the brainstem V12Gy-brainstem, D0.5cm3-brainstem and
D0.035 cm3-brainstem are lower in the BO versus VC technique, and
with the parameters V50% (whole brain) and V12Gy-cerebrum higher in BO versus
VC. Our goal is to keep the dose to the brainstem as low as possible and, if
possible, at most between 12 Gy and 15 Gy. The BO technique meets our purposes
and is considered clinically acceptable at our institution.
References
[1]
Bennetto, L., Patel, N.K. and Fuller, G. (2007) Trigeminal Neuralgia and Its Management. British Medical Journal, 334, 201-205. https://doi.org/10.1136/bmj.39085.614792.BE
[2]
Debono, B., et al. (2019) Dedicated Linear Accelerator Radiosurgery for Classic Trigeminal Neuralgia: A Single-Center Experience with Long-Term Follow-Up. World Neurosurgery, 121, e775-e785. https://doi.org/10.1016/j.wneu.2018.09.222
[3]
Popple, R.A., et al. (2018) The Virtual Cone: A Novel Technique to Generate Spherical Dose Distributions Using a Multileaf Collimator and Standardized Control-Point Sequence for Small Target Radiation Surgery. Advances in Radiation Oncology, 3, 421-430. https://doi.org/10.1016/j.adro.2018.02.011
[4]
Brown, T.A.D., Ayers, R.G. and Popple, R.A. (2022) Commissioning a Multileaf Collimator Virtual Cone for the Stereotactic Radiosurgery of Trigeminal Neuralgia. Journal of Applied Clinical Medical Physics, 23, e13562. https://doi.org/10.1002/acm2.13562
[5]
Sudahar, H., Kurup, P.G.G., Murali, V. and Velmurugan, J. (2012) Dosimetric Analysis of Trigeminal Nerve, Brain Stem Doses in CyberKnife Radiosurgery of Trigeminal Neuralgia. Journal of Medical Physics, 37, 124-128. https://doi.org/10.4103/0971-6203.99225
[6]
Klassen, P.D., Ivaturi, S.K. and Hendricks, B.K. (2022) Trigeminal Rhizotomy Using Gyroscopic Radiosurgery: A Case Report. Cureus, 14, e24951. https://doi.org/10.7759/cureus.24951
[7]
Kano, H., et al. (2017) Estimating the Risks of Adverse Radiation Effects after Gamma Knife Radiosurgery for Arteriovenous Malformations. Stroke, 48, 84-90. https://doi.org/10.1161/STROKEAHA.116.014825
[8]
Bentzen, S.M., et al. (2010) Quantitative Analyses of Normal Tissue Effects in the Clinic (QUANTEC): An Introduction to the Scientific Issues. International Journal of Radiation Oncology, Biology, Physics, 76, S3-S9. https://doi.org/10.1016/j.ijrobp.2009.09.040
[9]
Tuleasca, C., et al. (2019) Stereotactic Radiosurgery for Trigeminal Neuralgia: A Systematic Review: International Stereotactic Radiosurgery Society Practice Guidelines. Journal of Neurosurgery, 130, 733-757. https://doi.org/10.3171/2017.9.JNS17545
[10]
Wilson, T.A., Karlsson, B., Huang, L., Ramanathan, D., Oyoyo, U. and Boling, W. (2020) Optimizing Radiosurgery for Trigeminal Neuralgia: Impact of Radiation Dose and Anatomic Target on Patient Outcomes. World Neurosurg, 143, e482-e491. https://doi.org/10.1093/neuros/nyaa447_556
[11]
Lettmaier, S. (2014) Radiosurgery in Trigeminal Neuralgia. Physica Medica: European Journal of Medical Physics, 30, 592-595. https://doi.org/10.1016/j.ejmp.2014.05.006
[12]
Timmerman, R.D. (2008) An Overview of Hypofractionation and Introduction to This Issue of Seminars in Radiation Oncology. Seminars in Radiation Oncology, 18, 215-222. https://doi.org/10.1016/j.semradonc.2008.04.001
[13]
Rose, M.S., et al. (2020) Multi-Institution Validation of a New High Spatial Resolution Diode Array for SRS and SBRT Plan Pretreatment Quality Assurance. Medical Physics, 47, 3153-3164. https://doi.org/10.1002/mp.14153
[14]
Xu, Q., et al. (2022) Implementing and Evaluating a High-Resolution Diode Array for Patient-Specific Quality Assurance of Robotic Brain Stereotactic Radiosurgery/Ra-diotherapy. Journal of Applied Clinical Medical Physics, 23, e13569. https://doi.org/10.1002/acm2.13569