Simulating Medical Imaging X-Ray Tubes with Various Parameters Using BEAMnrc Monte Carlo Software

DOI: 10.4236/ojrad.2022.123014, PP. 125-141

Keywords: Bremsstrahlung, Filter, Monte Carlo, Spectral Distribution, X-Ray Tube

Full-Text   Cite this paper   Add to My Lib

Abstract:

Context: Medical imaging has a wide range of applications in today’s society. Basic projectional radiography, CT scans, mammograms and a range of other advanced technologies all use x-rays to create a large number of examinations every day across the world. The most essential component of such medical equipment is the x-ray tube, which creates and produces x-rays. Objective: We describe and investigate an abstract model-geometry of a simple x-ray tube utilizing the open-source software package of BEAMnrc of the EGSnrcmp family, which is well validated by several studies over the years, for high and low energy photons generation. Methodology: Our research focuses on two different electron beam energies: 120 keV and 30 keV. The 120 keV is the typical energy for simple projectional radiographic exams and CT examinations, whereas the 30 keV is the typical energy of mammography. Results: Two different anode materials are used for each case, Gold (Au) and Tungsten (W) for 120 keV because these are the most common in projectional radiography and CT; Molybdenum (Mo) and Rhodium (Rh) for 30 keV because with these targets most mammography exams are carried out. The aim of this work is to show how the BEAMnrc software package can simulate effectively x-ray generation of low-energy photons which are utilized in modern medical imaging procedures. We describe useful information on anode-target characteristics, such as anode angle, anode material, and metal filter materials, based on previous quality studies even by using software other than BEAMnrc. Conclusion: We demonstrate that BEAMnrc can be efficiently used for Monte Carlo modeling of low-energy photons.

References

[1]  Li, X., Samei, E., Segars, W.P., Sturgeon, M.G., Colsher, G.J., Toncheva, G., Yoshizumi, T.T., et al. (2011) Patient-Specific Radiation Dose and Cancer Risk Estimation in CT: Part I. Development and Validation of a Monte Carlo Program. Medical Physics, 38, 397-407.
https://doi.org/10.1118/1.3515839
[2]  Omar, A., Bujila, R., Fransson, A., Andreo, P. and Poludniowski, G. (2016) A Framework for Organ Dose Estimation in X-Ray Angiography and Interventional Radiology Based on Dose-Related Data in DICOM Structured Reports. Physics in Medicine and Biology, 61, 3063-3038.
https://doi.org/10.1088/0031-9155/61/8/3063
[3]  Muller, M. and Hendriks, B.H.W. (2013) Recovering Intrinsic fluorescence by Monte Carlo Modeling. Journal of Biomedical Optics, 18, Article ID: 027009.
https://doi.org/10.1117/1.JBO.18.2.027009
[4]  Ay, M.R., Sarkar, S., Shahriari, M., Sardari, D. and Zaidi, H. (2005) Assessment of Different Computational Models for Generation of X-Ray Spectra in Diagnostic Radiology and Mammography. Medical Physics, 32, 1660-1675.
https://doi.org/10.1118/1.1906126
[5]  Tennant, M. and Kruger, E. (2013) A Dental Public Health Approach Based on Computational Mathematics: Monte Carlo Simulation of Childhood Dental Decay. International Dental Journal, 63, 39-42.
https://doi.org/10.1111/idj.12003
[6]  Andreo, P. (2018) Monte Carlo Simulations in Radiotherapy Dosimetry. Radiation Oncology, 13, Article No. 121.
https://doi.org/10.1186/s13014-018-1065-3
[7]  Salehi, Z., Ali, Y.N.K. and Yusoff, A.L. (2012) X-Ray Spectra and Quality Parameters from Monte Carlo Simulation and Analytical Filters. Applied Radiation and Isotopes, 70, 2586-2589.
https://doi.org/10.1016/j.apradiso.2011.12.007
[8]  Adeli, R., Shirmardi, S.P., Amiri, J., Singh, V.P. and Medhat, M.E. (2015) Simulation and Comparison of Radiology X-Ray Spectra by MCNP and GEANT4 Codes. Journal of Paramedical Sciences (JPS), 6, 8-14.
[9]  Homolka, P. and Figl, M. (2018) Equivalent Thicknesses of Beam Hardening Filters Consisting of Aluminum, Copper, Al/Cu and Al/Gold Combinations and Plumbiferous Acrylic for 40 to 150 kVp Diagnostic Spectra. Journal of Radiological Protection, 38, 1269-1283.
https://doi.org/10.1088/1361-6498/aadaf4
[10]  Cheng, Y., Zhang, J., Lee, Y.Z., Gao, B., Dike, S., Lin, W., Lu, J.P., et al. (2004) Dynamic Radiography Using a Carbon-Nanotube-Based Field-Emission X-Ray Source. Review of Scientific Instruments, 75, 3264-3267.
https://doi.org/10.1063/1.1791313
[11]  Knoll, G.F. (2010) Radiation Detection and Measurement. 4th Edition, John Wiley & Sons Inc., Hoboken.
[12]  Mesbahia, A. and Zakariaee, S.S. (2013) Effect of Anode Angle on Photon Beam Spectra and Depth Dose Characteristics for X-RAD320 Orthovoltage Unit. Reports of Practical Oncology & Radiotherapy, 18, 148-152.
https://doi.org/10.1016/j.rpor.2012.12.001
[13]  Kim, G. and Lee, R. (2016) Effect of Target Angle and Thickness on the Heel Effect and X-Ray Intensity Characteristics for 70 kV X-Ray Tube Target. Progress in Medical Physics, 27, 272-276.
https://doi.org/10.14316/pmp.2016.27.4.272
[14]  Burgess, A.E. (1985) Physical Measurements of Heavy Metal Filter Performance. Medical Physics, 12, 225-231.
https://doi.org/10.1118/1.595709
[15]  Siedband, M.P. (1987) Beam Filtration in Diagnostic Radiology. In: Garrett, D.A. and Brachem, D.A., Eds., Real-Time Radiologic Imaging: Medical and Industrial Applications, American Society for Testing and Materials, West Conshohocken, 156-167.
https://doi.org/10.1520/STP27505S
[16]  Brenner, D.J. and Amols, H.I. (1989) Enhanced Risk from Low-Energy Screen-Film Mammography X-Rays. The British Journal of Radiology, 62, 910-914.
https://doi.org/10.1259/0007-1285-62-742-910
[17]  Ay, M.R., Shahriari, M., Sarkar, S., Adib, M. and Zaidi, H. (2004) Monte Carlo Simulation of X-Ray Spectra in Diagnostic Radiology and Mammography Using MCNP4C. Physics in Medicine and Biology, 49, 4897-4917.
https://doi.org/10.1088/0031-9155/49/21/004
[18]  Salvat, F., Fernandez-Varea, J.M., Sempau, J. and Llovet, X. (2006) Monte Carlo Simulation of Bremsstrahlung Emission by Electrons. Radiation Physics and Chemistry, 75, 1201-1219.
https://doi.org/10.1016/j.radphyschem.2005.05.008
[19]  Bote, D., Llovet, X. and Salvat, F. (2008) Monte Carlo Simulation of Characteristic X-Ray Emission from Thick Samples Bombarded by Kiloelectronvolt Electrons. Journal of Physics D: Applied Physics, 41, Article ID: 105304.
https://doi.org/10.1088/0022-3727/41/10/105304
[20]  Maged, M., Chakir, E., Boukhal, H., Saeed, M. and Bardouni, T.E. (2016) Evaluation of Variance Reduction Techniques in BEAMnrc Monte Carlo Simulation to Improve the Computing Efficiency. Journal of Radiation Research and Applied Sciences, 9, 424-430.
https://doi.org/10.1016/j.jrras.2016.05.005
[21]  Bootsma, G.J., Nordstrom, H., Eriksson, M. and Jaffray, D.A. (2020) Monte Carlo kilovoltage X-Ray Tube Simulation: A Statistical Analysis and Compact Simulation Method. Physica Medica, 72, 80-87.
https://doi.org/10.1016/j.ejmp.2020.03.015
[22]  Hjorringgaard, G.J., Ankjaergaard, C., Bailey, M. and Miller, A. (2020) Alanine Pellet Dosimeter Efficiency in a 40 kV X-Ray Beam Relative to Cobalt-60. Radiation Measurements, 136, Article ID: 106374.
https://doi.org/10.1016/j.radmeas.2020.106374
[23]  Rogers, D.W.O., Walters, B. and Kawrakow, I. (2021) BEAMnrc Users Manual. NRCC Report PIRS-0509(A), National Research Council of Canada.
[24]  Kawrakow, I., Rogers, D.W.O. and Walters, B. (2004) Large Efficiency Improvements in BEAMnrc Using Directional Bremsstrahlung Splitting. Medical Physics, 31, 2883-2898.
https://doi.org/10.1118/1.1788912
[25]  Dance, D.R. (2014) Diagnostic Radiology Physics. IAEA, Vienna.
[26]  Verhaegen, F. and Castellano, I.A. (2002) Microdosimetric Characterisation of 28 KVp Mo/Mo, Rh/Rh, Rh/Al, W/Rh and Mo/Rh Mammography X Ray Spectra. Radiation Protection Dosimetry, 99, 393-396.
https://doi.org/10.1093/oxfordjournals.rpd.a006816
[27]  Omar, A., Andreo, P. and Poludniowski, G. (2018) A Model for the Emission of K and L X Rays from an X-Ray Tube. Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Matter, 437, 36-47.
https://doi.org/10.1016/j.nimb.2018.10.026
[28]  Shi, C. and Wang, B. (2017) Preliminary Monte Carlo Investigation of Using Ir-192 as the Source for Real Time Imaging Purpose. International Journal of Medical Physics, Clinical Engineering and Radiation Oncology, 6, 21-30.
https://doi.org/10.4236/ijmpcero.2017.61003
[29]  Ma, C.M. and Rogers, D.W. (2012) BEAMDP Users Manual. NRCC Report PIRS-0509(C), National Research Council of Canada.
[30]  Brinkert, T. (2015) Grace User’s Guide (for Grace-5.1.25). Semibyte Srls, Provincia di Prato.
[31]  Thompson, C.A., Kirz, J., Attwood, T.D., Gullikson, M.E., Liu, Y., et al. (2009) X-Ray Data Booklet. 3rd Edition, Lawrence Berkeley National Laboratory, Berkeley, CA.

Full-Text

comments powered by Disqus

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133

WeChat 1538708413