Purpose:?Patient-specific QA (PSQA) measurements for carbon ion radiotherapy (CIRT) are critical components of processes designed to identify?discrepancies between calculated and delivered doses. We report the results of PSQA conducted at the QST Hospital during the period from September 2017 to March 2018. Methods:?We analyzed PSQA results for 1448 fields for 10 disease sites with various target volumes, target depths and number of energy layers. For the PSQA, all the planned beams were recalculated on a water phantom with treatment planning software. The recalculated dose distributions were compared with the measured distributions using a 2D?ionization chamber array at three depths, including 95% of the area of the prescription dose. These recalculated dose distributions were evaluated using the 3%/3mm gamma index with a passing threshold of 90%. Results:?The passing rates for prostate, head and neck, and bone and soft tissue were?96.8%, 99.3%, and 91.7%, respectively. Additionally, 94.7% of lung plans with low energy beams passed. Overall, the CIRT in the QST Hospital reached a high passing rate of more than 95%.?Although the remaining 5% failed to pass, there was no dependence between measurement depth and disease sites in these failures. Conclusion: Using PSQA measurements, we confirmed consistency between the planned and delivered doses for CIRT using the full energy scanning method.
References
[1]
[1]Kamada, T. (2016) Twenty Years of Carbon Ion Radiation Therapy at the National Institute of Radiological Sciences: Accomplishments and Prospects. International Journal of Particle Therapy, 2, 459-463. https://doi.org/10.14338/IJPT-15-00030.1
[2]
Furukawa, T., Inaniwa, T., Sato, S., Shirai, T., Takei, Y., Takeshita, E., et al. (2010) Performance of the NIRS Fast Scanning System for Heavy-Ion Radiotherapy. Medical Physics, 37, 5672-5682. https://doi.org/10.1118/1.3501313
[3]
Jakel, O., Hartmann, G.H., Karger, C.P., Heeg, P. and Rassow, J. (2000) Quality Assurance for a Treatment Planning System in Scanned Ion Beam Therapy. Medical Physics, 27, 1588-1600. https://doi.org/10.1118/1.599025
[4]
Mackin, D., Zhu, X.R., Poenisch, F., Li, H., Sahoo, N., Kerr, M., et al. (2014) Spot-Scanning Proton Therapy Patient-Specific Quality Assurance: Results from 309 Treatment Plans. International Journal of Particle Therapy, 1, 711-720. https://doi.org/10.14338/IJPT-14-00017.1
[5]
Furukawa, T., Inaniwa, T., Hara, Y., Mizushima, K., Shirai, T. and Noda, K. (2013) Patient-Specific QA and Delivery Verification of Scanned Ion Beam at NIRS-HIMAC. Medical Physics, 40, 121707. https://doi.org/10.1118/1.4828845
[6]
Noda, K. (2016) Beam Delivery Method for Carbon-Ion Radiotherapy with the Heavy-Ion Medical Accelerator in Chiba. International Journal of Particle Therapy, 2, 481-489. https://doi.org/10.14338/IJPT-15-00041.1
[7]
Inaniwa, T., Furukawa, T., Sato, S., Tomitai, T., Kobayashi, M., Minohara, S., et al. (2008) Development of Treatment Planning for Scanning Irradiation at HIMAC. Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 266, 2194-2198. https://doi.org/10.1016/j.nimb.2008.02.070
[8]
Inaniwa, T. and Kanematsu, N. (2015) A Trichrome Beam Model for Biological Dose Calculation in Scanned Carbon-Ion Radiotherapy Treatment Planning. Physics in Medicine & Biology, 60, 437-451. https://doi.org/10.1088/0031-9155/60/1/437
[9]
Low, D.A., Harms, W.B., Mutic, S. and Purdy, J.A. (1998) A Technique for the Quantitative Evaluation of Dose Distributions. Medical Physics, 25, 656-661. https://doi.org/10.1118/1.598248
[10]
Li, H., Sahoo, N., Poenisch, F., Suzuki, K., Li, Y., Li, X., et al. (2013) Use of Treatment Log Files in Spot Scanning Proton Therapy as Part of Patient-Specific Quality Assurance. Medical Physics, 40, 021703. https://doi.org/10.1118/1.4773312