全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...

A Comparison of Arterial Oxygenation between 60% O2 CPAP and 100% O2 CPAP during One-Lung Ventilation: A Prospective Randomized Controlled Study

DOI: 10.4236/ojanes.2023.131001, PP. 1-14

Keywords: CPAP, Double-Lumen Tube, Hyperoxemia, Hypoxemia, One-Lung Ventilation

Full-Text   Cite this paper   Add to My Lib

Abstract:

Background: One-lung ventilation (OLV) is generally adopted for thoracic surgery. The systemic application of a high fraction of inspiratory oxygen (F1O2) and continuous positive airway pressure (CPAP) to the non-ventilated lung is useful for preventing arterial oxygen desaturation. The adverse effects of elevated F1O2 include oxidative lung injury, resorption atelectasis and coronary and peripheral vasoconstriction. It is preferable to avoid hyperoxemia in patients with complications such as chronic obstructive pulmonary disease, idiopathic pneumonia, and bleomycin-treated lungs. We aimed to determine whether the application of 60% O2 CPAP to the non-ventilated lung is sufficient to provide adequate oxygenation with 60% O2 to the ventilated lung. Methods: A total of 70 patients scheduled to receive elective thoracic surgery requiring OLV were recruited. Left double-lumen tubes were applicable in all surgeries. Patients were randomly allocated to one of two groups, to receive either 60% O2 CPAP (60% CPAP group, n = 35), or 100% O2 CPAP (100% CPAP group, n = 35) at a setting of 2 - 3 cmH2O, applied to the non-ventilated lung. Arterial blood gas analyses were obtained at the following stages: RA, spontaneous breathing under room air (RA); TLV, during total lung ventilation (TLV) prior to the initiation of OLV; T5, 5 min after the initiation of OLV; T15, 15 min after the initiation of OLV; T30, 30 min after the initiation of OLV. Results: The PaO2 value in 60% CPAP group vs. 100% CPAP group at each measurement were as follows: RA (mean [standard deviation: SD], 89.7 [8.2] mmHg vs. 85.8 [11.9] mmHg); TLV (277.9 [52.9] mmHg vs. 269.2 [44.0] mmHg); T5 (191.4 [67.9] mmHg vs. 192.3 [66.0] mmHg); T15 (143.2 [67.3] mmHg vs. 154.7 [60.8] mmHg) and T30 (95.6 [32.0] mmHg vs. 112.5 [36.5] mmHg), respectively. Among the five measurement points, T30 was the only time point at which the 100% CPAP group showed a significantly greater PaO2 value than the 60% CPAP group (p = 0.0495). The SaO2 at T30 in the 100% CPAP group (97.4 [2.0]%) was also significantly greater than that in the 60% CPAP group (96.3 [2.2]%, p = 0.039). No differences were found between the groups regarding changes to the overall PaO2 values (p = 0.44) and SaO2 values (p = 0.23) during the study period. Conclusions: Oxygenation could be safely maintained in relatively healthy patients with 60% O2 OLV and 60%

References

[1]  Karzai, W. and Schwarzkopf, K. (2009) Hypoxemia during One-Lung Ventilation: Prediction, Prevention, and Treatment. Anesthesiology, 110, 1402-1411.
https://doi.org/10.1097/ALN.0b013e31819fb15d
[2]  Lohser, J. and Slinger, P. (2015) Lung Injury after One-Lung Ventilation: A Review of the Pathophysiologic Mechanisms Affecting the Ventilated and the Collapsed Lung. Anesthesia & Analgesia, 121, 302-318.
https://doi.org/10.1213/ANE.0000000000000808
[3]  Slinger, P.D., Kruger, M., McRae, K. and Winton, T. (2001) Relation of the Static Compliance Curve and Positive End-Expiratory Pressure to Oxygenation during One-Lung Ventilation. Anesthesiology, 95, 1096-1102.
https://doi.org/10.1097/00000542-200111000-00012
[4]  Brodsky, J.B. and Lemmens, H.J.M. (2003) Left Double-Lumen Tubes: Clinical Experience with 1,170 Patients. Journal of Cardiothoracic and Vascular Anesthesia, 17, 289-298.
https://doi.org/10.1016/S1053-0770(03)00046-6
[5]  Hurford, W.E. and Alfille, P.H. (1993) A Quality Improvement Study of the Placement and Complications of Double-Lumen Endobronchial Tubes. Journal of Cardiothoracic and Vascular Anesthesia, 7, 517-520.
https://doi.org/10.1016/1053-0770(93)90305-5
[6]  Fujiwara, M., Abe, K. and Mashimo, T. (2001) The Effect of Positive End-Expiratory Pressure and Continuous Positive Airway Pressure on the Oxygenation and Shunt Fraction during One-Lung Ventilation with Propofol Anesthesia. Journal of Clinical Anesthesia, 13, 473-477.
https://doi.org/10.1016/S0952-8180(01)00310-5
[7]  Campos, J.H. and Feider, A. (2018) Hypoxia during One-Lung Ventilation—A Review and Update. Journal of Cardiothoracic and Vascular Anesthesia, 32, 2330-2338.
https://doi.org/10.1053/j.jvca.2017.12.026
[8]  Bickler, P.E., Feiner, J.R., Lipnick, M.S., Batchelder, P., MacLeod, D.B. and Severinghaus, J.W. (2017) Effects of Acute, Profound Hypoxia on Healthy Humans: Implications for Safety of Tests Evaluating Pulse Oximetry or Tissue Oximetry Performance. Anesthesia & Analgesia, 124, 146-153.
https://doi.org/10.1213/ANE.0000000000001421
[9]  Asfar, P., Singer, M. and Radermacher, P. (2015) Understanding the Benefits and Harms of Oxygen Therapy. Intensive Care Medicine, 41, 1118-1121.
https://doi.org/10.1007/s00134-015-3670-z
[10]  Sjoberg, F. and Singer, M. (2013) The Medical Use of Oxygen: A Time for Critical Reappraisal. Journal of Internal Medicine, 274, 505-528.
https://doi.org/10.1111/joim.12139
[11]  Spoelstra-de Man, A.M., Smit, B., Oudemans-Van Straaten, H.M. and Smulders, Y.M. (2015) Cardiovascular Effects of Hyperoxia during and after Cardiac Surgery. Anaesthesia, 70, 1307-1319.
https://doi.org/10.1111/anae.13218
[12]  Meyhoff, C.S., Staehr, A.K. and Rasmussen, L.S. (2012) Rational Use of Oxygen in Medical Disease and Anesthesia. Current Opinion in Anesthesiology, 25, 363-370.
https://doi.org/10.1097/ACO.0b013e328352b402
[13]  Repine, J.E., Bast, A. and Lankhorst, I. (1997) Oxidative Stress in Chronic Obstructive. Pulmonary Disease. Oxidative Stress Study Group. American Journal of Respiratory and Critical Care Medicine, 156, 341-357.
https://doi.org/10.1164/ajrccm.156.2.9611013
[14]  Kinnula, V.L., Fattman, C.L., Tan, R.J. and Oury, T.D. (2005) Oxidative Stress in Pulmonary Fibrosis: A Possible Role for Redox Modulatory Therapy. American Journal of Respiratory and Critical Care Medicine, 172, 417-422.
https://doi.org/10.1164/rccm.200501-017PP
[15]  Hughes, S.A. and Benumof, J.L. (1990) Operative Lung Continuous Positive Airway. Pressure to Minimize FIO2 during One-Lung Ventilation. Anesthesia & Analgesia, 71, 92-95.
https://doi.org/10.1213/00000539-199007000-00017
[16]  Misthos, P., Katsaragakis, S., Milingos, N., Kakaris, S., Sepsas, E., Athanassiadi, K., Theodorou, D. and Skottis, I. (2005) Postresectional Pulmonary Oxidative Stress in Lung Cancer Patients. The Role of One-Lung Ventilation. European Journal of Cardio-Thoracic Surgery, 27, 379-382.
https://doi.org/10.1016/j.ejcts.2004.12.023
[17]  Hannallah, M., Benumof, J.L., Silverman, P.M., Kelly, L.C. and Lea, D. (1997) Evaluation of an Approach to Choosing a Left Double-Lumen Tube Size Based on Chest Computed Tomographic Scan Measurement of Left Mainstem Bronchial Diameter. Journal of Cardiothoracic and Vascular Anesthesia, 11, 168-171.
https://doi.org/10.1016/S1053-0770(97)90208-1
[18]  Cohen, E. and Eisenkraft, J.B. (1996) Positive End-Expiratory Pressure during one-lung Ventilation Improves Oxygenation in Patients with Low Arterial Oxygen Tensions. Journal of Cardiothoracic and Vascular Anesthesia, 10, 578-582.
https://doi.org/10.1016/S1053-0770(96)80131-5
[19]  Fukuoka, N., Iida, H., Akamatsu, S., Nagase, K., Iwata, H. and Dohi, S. (2009) The Association between the Initial End-Tidal Carbon Dioxide Difference and the Lowest Arterial Oxygen Tension Value Obtained during One-Lung Anesthesia with Propofol or Sevoflurane. Journal of Cardiothoracic and Vascular Anesthesia, 23, 775-779.
https://doi.org/10.1053/j.jvca.2009.03.023
[20]  Louw, A., Cracco, C., Cerf, C., Harf, A., Duvaldestin, P., Lemaire, F. and Brochard, L. (2001) Accuracy of Pulse Oximetry in the Intensive Care Unit. Intensive Care Medicine, 27, 1606-1613.
https://doi.org/10.1007/s001340101064
[21]  Wouters, P.F., Gehring, H., Meyfroidt, G., Ponz, L., Gil-Rodriguez, J., Hornberger, C., Bonk, R., Frankenberger, H., Benekos, K., Valais, J., Avgerinos, J. and Konecny, E. (2002) Accuracy of Pulse Oximeters: The European Multi-Center Trial. Anesthesia & Analgesia, 94, S13-S16.
[22]  Webb, R.K., Ralston, A.C. and Runciman, W.B. (1991) Potential Errors in Pulse Oximetry II. Effects of Changes in Saturation and Signal Quality. Anaesthesia, 46, 207-212.
https://doi.org/10.1111/j.1365-2044.1991.tb09411.x
[23]  Damiani, E., Donati, A. and Girardis, M. (2018) Oxygen in the Critically Ill: Friend or Foe? Current Opinion in Anesthesiology, 31, 129-135.
https://doi.org/10.1097/ACO.0000000000000559
[24]  Farquhar, H., Weatherall, M., Wijesinghe, M., Perrin, K., Ranchord, A., Simmonds, M. and Beasley, R. (2009) Systematic Review of Studies of the Effect of Hyperoxia on Coronary Blood Flow. American Heart Journal, 158, 371-377.
https://doi.org/10.1016/j.ahj.2009.05.037
[25]  Grichnik, K.P. and D’Amico, T.A. (2004) Acute Lung Injury and Acute Respiratory Distress. Syndrome after Pulmonary Resection. Seminars in Cardiothoracic and Vascular Anesthesia, 8, 317-334.
https://doi.org/10.1177/108925320400800405
[26]  Xu, Z., Gu, L., Bian, Q., Li, P., Wang, L., Zhang, J. and Qian, Y. (2016) Oxygenation, Inflammatory Response and Lung Injury during One Lung Ventilation in Rabbits Using Inspired Oxygen Fraction of 0.6 vs. 1.0. Journal of Biomedical Research, 31, 56-64.
[27]  Pannu, S.R. (2016) Too Much Oxygen: Hyperoxia and Oxygen Management in. Mechanically Ventilated Patients. Seminars in Respiratory and Critical Care Medicine, 37, 16-22.
https://doi.org/10.1055/s-0035-1570359
[28]  Verhage, R.J.J., Boone, J., Rijkers, G.T., Cromheecke, G.J., Kroese, A.C., Weijs, T.J., Borel Rinkes, I.H.M. and van Hillegersberg, R. (2014) Reduced Local Immune Response with Continuous Positive Airway Pressure during One-Lung Ventilation for Oesophagectomy. British Journal of Anaesthesia, 112, 920-928.
https://doi.org/10.1093/bja/aet476
[29]  Houge Jr., C.W. (1994) Effectiveness of Low Levels of Nonventilated Lung Continuous. Positive Airway Pressure in Improving Arterial Oxygenation during One-Lung Ventilation. Anesthesia & Analgesia, 79, 364-367.
https://doi.org/10.1213/00000539-199408000-00029
[30]  Badner, N.H., Goure, C., Bennett, K.E. and Nicolaou, G. (2011) Role of Continuous Positive. Airway Pressure to the Non-Ventilated Lung during One-Lung Ventilation with Low Tidal Volumes. HSR Proceedings in Intensive Care & Cardiovascular Anesthesia, 3, 189-194.
[31]  Levin, A.I., Coetzee, J.F. and Coetzee, A. (2008) Arterial Oxygenation and One-Lung. Anesthesia. Current Opinion in Anesthesiology, 21, 28-36.
https://doi.org/10.1097/ACO.0b013e3282f2bb79
[32]  Lumb, A.B. and Slinger, P. (2015) Hypoxic Pulmonary Vasoconstriction: Physiology and Anesthetic Implications. Anesthesiology, 122, 932-946.
https://doi.org/10.1097/ALN.0000000000000569
[33]  Slinger, P., Suissa, S. and Triolet, W. (1992) Predicting Arterial Oxygenation during One-Lung Anaesthesia. Canadian Journal of Anesthesia, 39, 1030-1035.
https://doi.org/10.1007/BF03008370
[34]  Slinger, P., Suissa, S., Adam, J. and Triolet, W. (1990) Predicting Arterial Oxygenation during One-Lung Ventilation with Continuous Positive Airway Pressure to the Nonventilated Lung. Journal of Cardiothoracic and Vascular Anesthesia, 4, 436-440.
https://doi.org/10.1016/0888-6296(90)90288-Q

Full-Text

comments powered by Disqus

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133

WeChat 1538708413