为了降低能耗,提高生活污水脱氮除磷效率,精准曝气是最关键因素之一。本文采用活性污泥法,通过微孔曝气,考察了连续式曝气和间歇式曝气循环3次或4次的条件下对生活污水处理300 min后的化学需氧量(COD)、氨氮(NH3-N)和总磷(TP)的浓度变化和去除效率。结果表明,采用连续曝气、3次循环曝气、4次循环曝气三种曝气模式对COD的去除率分别为89.60%、79.20%、85.44%,对NH3-N的去除率分别为81.37%、87.83%、88.73%,对总磷的去除率分别为59.60%、61.87%、62.24%。结果表明,循环曝气可以提高脱氮除磷效率,而且循环次数越多,脱氮除磷效率越高。
In order to reduce energy consumption and improve removal efficiency of nitrogen and phosphorus for domestic sewage treatment, precise aeration is one of the most critical factors. In this paper, the concentration changes and removal efficiency of chemical oxygen demand (COD), ammonia nitrogen (NH3-N) and total phosphorus (TP) after domestic sewage treatment for 300 min under the conditions that continuous aeration or cyclic alternating aeration for 3 or 4 times were investigated by activated sludge method through microporous aeration. The experiments showed that the removal rates of COD, NH3-N and TP were 89.60%, 79.20%, 85.44%; 81.37%, 87.83%, 88.73%; and 59.60%, 61.87%, 62.24%, respectively by continuous aeration, three cycle aeration, and four cycle aeration. The results show that the cycle aeration can improve the efficiency of nitrogen and phosphorus removal, and the more cycles aeration, the higher the efficiency of nitrogen and phosphorus removal.

References

[1]  王冠平, 许建华, 肖羽堂. 生物接触氧化池两种不同曝气方式的充氧性能的比较研究[J]. 净水技术, 1999(4): 11-14.
[2]  赵志强, 梁波, 李苛杰. 浅谈生活污水来源以及处理方法[J]. 环境与生活, 2014, 90(8): 12-14.
[3]  Mits, M., Beloshenko, K. and Bozhkov, A. (2021) Research on Improvement of the Method of Periodic Aeration of Wastewater. Bulletin of the National Technical University ?KhPI? Series New Solutions in Modern Technol-ogies, 1, 90-95.
https://doi.org/10.20998/2413-4295.2021.01.13
[4]  闫飞龙, 王怡, 王文怀, 等. 曝气方式对复合人工湿地处理城镇生活污水的影响[J]. 中国给水排水, 2021, 37(19): 85-90.
[5]  Moga, I.C., Donu, O.G., Bran, N., et al. (2019) Aeration System to Be Used in Wastewater Treatment. IOP Conference Series Materials Science and Engineering, 572, 121-125.
https://doi.org/10.1088/1757-899X/572/1/012105
[6]  郑琬琳, 史彦伟, 高放, 等. 改良AAO工艺间歇曝气对微生物群落特征及运行效果影响[J]. 给水排水, 2021, 57(5): 34-39+44.
[7]  高廷耀, 顾国维. 水污染控制工程(第四版?下册) [M]. 北京: 高等教育出版社, 2005: 122+125-126+165-166+246.
[8]  胡丽萍, 阮辰旼. 利用污泥沉降比SV_(30)分析生化工艺运行状况[J]. 净水技术, 2016, 35(2): 105-108.
[9]  郑琬琳, 史彦伟, 高放, 等. 改良AAO工艺间歇曝气对微生物群落特征及运行效果影响[J]. 给水排水, 2021, 57(5): 34-39+44.
[10]  马永鹏, 何争光, 宋宏杰, 等. 不同曝气方式对M-CASS处理酒精废水的影响[J]. 水处理技术, 2010, 36(9): 110-113.

Full-Text

comments powered by Disqus

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133