全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...

Analytical Method Development and Validation of Some Biosimilar Drugs by High Performance Thin Layer Chromatography

DOI: 10.4236/ajac.2023.143007, PP. 121-133

Keywords: Biosimilars, Etanercept, Filgrastim, Method Development, Validation

Full-Text   Cite this paper   Add to My Lib

Abstract:

A simple and rapid HPTLC analytical method has been developed and validated for the determination of Etanercept and Filgrastim in pure form and in marketed formulation. Both the drugs were chromatographed on silica gel 60 F254s HPTLC plates, as stationary phase. The mobile phase optimized for Filgrastim and Etanercept was Water: n-butanol (7.5:2.5 v/v) and Isopropyl alcohol: water (6.5:4.5 v/v), respectively. The chromatogram obtained was scanned at 225 nm and 222 nm for filgrastim and etanercept which resulted in a retention factor of 0.45 ± 0.07 and 0.32 ± 0.03, respectively. The method was validated for parameters like linearity, accuracy, precision, specificity and robustness. Recovery studies were performed at three concentration levels, to demonstrate suitability, accuracy and precision of proposed method. Statistical analysis proved that the proposed method is accurate and reproducible with linearity in the range of 500 to 3000 ng/band for filgrastim and 200 to 1200 ng/band for etanercept. The limit of detection and limit of quantification for filgrastim was found to be 63.418 ng/band and 192.177 ng/band. For etanercept, LOD and LOQ were found to be 33.381 ng/band and 101.153 ng/band, respectively. The proposed method can be employed for the routine analysis of selected biosimilars.

References

[1]  Goffe, B. and Cather, J.C. (2003) Etanercept: An Overview. Journal of the American Academy of Dermatology, 49, 105-111.
https://doi.org/10.1016/mjd.2003.554
[2]  Strand, V., Girolomoni, G., Schiestl, M., Mayer, R.E., Friccius-Quecke, H. and McCamish, M. (2017) The Totality-of-the-Evidence Approach to the Development and Assessment of GP2015, a Proposed Etanercept Biosimilar. Current Medical Research and Opinion, 33, 993-1003.
https://doi.org/10.1080/03007995.2017.1288612
[3]  Dalmora, S.L., D’Avila, F.B., da Silva, L.M., Bergamo, A.C. and Zimmermann, E.S. (2009) Development and Validation of a Capillary Zone Electrophoresis Method for Assessment of Recombinant Human Granulocyte Colony-Stimulating Factor in Pharmaceutical Formulations and Its Correlation with Liquid Chromatography Methods and Bioassay. Journal of Chromatography B, 877, 2471-2476.
https://doi.org/10.1016/j.jchromb.2009.06.011
[4]  Sörgel, F., Schwebig, A., Holzmann, J., Prasch, S., Singh, P. and Kinzig, M. (2015) Comparability of Biosimilar Filgrastim with Originator Filgrastim: Protein Characterization, Pharmacodynamics, and Pharmacokinetics. BioDrugs, 29, 123-131.
https://doi.org/10.1007/s40259-015-0124-7
[5]  Sonia, K., Bhavyashree, B. and Lakshmi, K.S. (2017) HPTLC Method Development and Validation: An Overview. Journal of Pharmaceutical Sciences and Research, 9, 652-657.
https://www.researchgate.net/publication/317754072_HPTLC_method_development_and_validation_An_overview
[6]  Srivastava, M.M. (2010) An Overview of HPTLC: A Modern Analytical Technique with Excellent Potential for Automation, Optimization, Hyphenation, and Multidimensional Applications. In: Srivastava, M.M., Ed., High Performance Thin Layer Chromatography (HPTLC), Springer, New York, 3-24.
https://doi.org/10.1007/978-3-642-14025-9_1
[7]  Weins, C. and Hauck, H.E. (1996) Advances and Developments in Thin Layer Chromatography. LC-GC International, 14, 455-471.
[8]  Chandel, S., Barhate, C.R., Srivastava, A.R., Kulkarni, S.R. and Kapadia, C.J. (2012) Development and Validation of HPTLC Method for Estimation of Tenoxicam and Its Formulations. Indian Journal of Pharmaceutical Sciences, 74, 36-40.
https://doi.org/10.4103/0250-474X.102541
[9]  Monireh, H., Masoumeh, G., Solmaz, G., Hossein, A. and Ghanbari, M.M. (2016) Development and Validation of a HPTLC Method for Analysis of Sunitinib Malate. Brazilian Journal of Pharmaceutical Sciences, 52, 595-601.
https://doi.org/10.1590/s1984-82502016000400003
[10]  Tayade, N.G. and Nagarsenker, M.S. (2007) Validated HPTLC Method of Analysis for Artemether and Its Formulations. Journal of Pharmaceutical and Biomedical Analysis, 43, 839-844.
https://doi.org/10.1016/j.jpba.2006.08.029
[11]  Dixit, R.P., Barhate, C.R. and Nagarsenkar, M.S. (2008) Stability Indicating HPTLC Method for Simultaneous Estimation of Ezetimibe and Simvatsatin. Chromatographia, 67, 101-107.
https://doi.org/10.1365/s10337-007-0459-4
[12]  ICH Harmonized Guideline Q2R1 (2005) Validation of Analytical Procedures: Text and Methodology (ICH Q2 (R1)).
[13]  Halim, L.A., Márquez, M., Maas-Bakker, R.F., Castañeda-Hernández, G., Jiskoot, W. and Schellekens, H. (2018) Quality Comparison of Biosimilar and Copy Filgrastim Products with the Innovator Product. Pharmaceutical Research, 35, Article No. 226.
https://doi.org/10.1007/s11095-018-2491-5
[14]  Magalhaes, V., Mantovani, M., Caruso, C., Facchini, F., Pascon, R. and Cagnacci, P. (2016) Physicochemical and Biological Comparison of the First Brazilian Biosimilar Filgrastim with Its Reference Product. Biosimilars, 6, 45-60.
https://doi.org/10.2147/BS.S107898
[15]  Cho, I.H., Lee, N., Song, D., Jung, S.Y., Bou-Assaf, G., Sosic, Z., Zhang, W. and Lyubarskaya, Y. (2016) Evaluation of the Structural, Physicochemical, and Biological Characteristics of SB4, a Biosimilar of Etanercept. mAbs, 8, 1136-1155.
https://doi.org/10.1080/19420862.2016.1193659
[16]  Maarschalkerweerd, A., Wolbink, G.J., Stapel, S.O., Jiskoot, W. and Hawe, A. (2011) Comparison of Analytical Methods to Detect Instability of Etanercept during Thermal Stress Testing. European Journal of Pharmaceutics and Biopharmaceutics, 78, 213-221.
https://doi.org/10.1016/j.ejpb.2011.01.012
[17]  Batkovska-Borozanova, I., Tonic-Ribarska, J. and Trajkovic-Jolevska, S. (2010) New High Performance Liquid Chromatography Method for Analysis of Filgrastim in Pharmaceutical Formulations. Webmedcentral Pharmaceutical Sciences, 1, WMC001117.
[18]  Luiz Dalmora, S., Maria Krug Masiero, S., Renato de Oliveira, P., da Silva Sangoi, M. and Brum Junior, L. (2006) Validation of an RP-LC Method and Assessment of rhG-CSF in Pharmaceutical Formulations by Liquid Chromatography and Biological Assay. Journal of Liquid Chromatography & Related Technologies, 29, 1753-1767.
https://doi.org/10.1080/10826070600716900
[19]  Qureshi, H.K., Veeresham, C. and Srinivas, C. (2021) Analytical Method Development and Validation of Filgrastim by UV and RP-UFLC Methods. American Journal of Analytical Chemistry, 12, 333-346.
https://doi.org/10.4236/ajac.2021.1212031
[20]  Biller, J., Morschheuser, L., Riedner, M. and Rohn, S. (2015) Development of Optimized Mobile Phases for Protein Separation by High Performance Thin Layer Chromatography. Journal of Chromatography A, 1415, 146-154.
https://doi.org/10.1016/j.chroma.2015.08.048
[21]  Abo-Gharam, A.H. and El-Kafrawy, D.S. (2022) Eco-Friendly Stability-Indicating HPTLC Micro-Determination of the First FDA Approved SARS-CoV-2 Antiviral Prodrug Remdesivir: Study of Degradation Kinetics and Structural Elucidation of the Degradants Using HPTLC-MS. Sustainable Chemistry and Pharmacy, 29, Article ID: 100744.
https://doi.org/10.1016/j.scp.2022.100744

Full-Text

comments powered by Disqus

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133

WeChat 1538708413