Effect of Molding Technique That Move Model Position Just before Formation in Production of Laminated Mouthguard

DOI: 10.4236/msa.2023.146020, PP. 325-335

Keywords: Laminated Mouthguard, Thermoforming, Molding Technique, Thickness

Full-Text   Cite this paper   Add to My Lib

Abstract:

Many molding techniques have been researched to ensure the thickness of custom mouthguards. The aim of this study was to clarify the effect on the thickness of a laminated mouthguard of a molding technique in which the model position is moved forward just before molding. Mouthguards were molded using a 3.0-mm-thick ethylene vinyl acetate mouthguard sheet and a pressure molding machine. The molding method was the normal molding method (condition C) and the molding technique (condition MP) in which the model position was moved 20 mm forward just before molding. Regarding the molding of the first layer (F) and the second layer (S), the following four molding methods based on the combination of conditions C and MP were compared; FC-SC, FC-SMP, FMP-SC, and FMP-SMP. Differences in mouthguard thickness due to molding conditions for the first and second layers were analyzed by two-way ANOVA and Bonferroni’s multiple comparison test. Significant differences were observed among all molding conditions on the labial surface, and the thicknesses were in the order FC-SC < FC-SMP < FMP-SC < FMP-SMP. FMP-SMP was 4.67 mm thick, which was 1.39 mm thicker than FC-SC. FC-SC was the thinnest at the cusp, and a significant difference was observed between other molding conditions. On the buccal side, significant differences were observed between all conditions except FC-SMP and FMP-SC, and the thicknesses were in the order FC-SC < FC-SMP, FMP-SC < FMP-SMP. The results of this study suggested that the labial and buccal sides of laminated mouthguards could be made 1.4 and 1.2 times thicker when a molding technique that moves the model position just before formation was used for the first and second layers. The reduction in thickness was suppressed by approximately 23.2% and approximately 10.7% on the labial and buccal sides, respectively, compared with the normal molding method.

References

[1]  Gialain, I.O., Coto, N.P., Driemeier, L., Noritomi, P.Y. and Dias, R.B. (2016) A Three-Dimensional Finite Element Analysis of the Sports Mouthguard. Dental Traumatology, 32, 409-415.
https://doi.org/10.1111/edt.12265
[2]  Bochnig, M.S., Oh, M.J., Nagel, T., Ziegler, F. and Jost-Brinkmann, P.G. (2017) Comparison of the Shock Absorption Capacities of Different Mouthguards. Dental Traumatology, 33, 205-213.
https://doi.org/10.1111/edt.12324
[3]  Gawlak, D., Mańka-Malara, K., Mierzwińska-Nastalska, E., Gieleta, R., Kamiński, T. and Luniewska, M. (2017) A Comparison of Impact Force Reduction by Polymer Materials Used for Mouthguard Fabrication. Acta of Bioengineering and Biomechanics, 19, 89-95.
[4]  Tribst, J.P.M., de Oliveira Da Piva, A.M., Borges, A.L.S. and Bottino, M.A. (2018) Influence of Custom-Made and Stock Mouthguard Thickness on Biomechanical Response to a Simulated Impact. Dental Traumatology, 34, 429-437.
https://doi.org/10.1111/edt.12432
[5]  Kalman, L., Dal, P.A.M.O., de Queiroz, T.S. and Tribst, J.P.M. (2021) Biomechanical Behavior Evaluation of a Novel Hybrid Occlusal Splint-Mouthguard for Contact Sports: 3D-FEA. Dentistry Journal, 10, Article No. 3.
https://doi.org/10.3390/dj10010003
[6]  Del, R.G. and Leyte, V.M.A. (2007) Fabricating a Better Mouthguard: Part I Factors Influencing Mouthguard Thinning. Dental Traumatology, 23, 149-154.
https://doi.org/10.1111/j.1600-9657.2006.00436.x
[7]  Geary, J.L. and Kinirons, M.J. (2008) Post Thermoforming Dimensional Changes of Ethylene Vinyl Acetate Used in Custom-Made Mouthguards for Trauma Prevention: A Pilot Study. Dental Traumatology, 24, 350-355.
https://doi.org/10.1111/j.1600-9657.2007.00550.x
[8]  Takahashi, M., Koide, K., Satoh, Y. and Iwasaki, S. (2016) Shape Change in Mouthguard Sheets During Thermoforming. Dental Traumatology, 32, 379-384.
https://doi.org/10.1111/edt.12261
[9]  Takeuchi, M. and Togaya, N. (2006) Effectiveness of Thermoforming Process for Fabricating of Intraoral Apparatus. Sunashobo, Tokyo, 21-26, 33-44, 54-55, 62-67. (In Japanese)
[10]  Takahashi, M. and Bando, Y. (2019) Thermoforming Technique for Maintaining the Thickness of Single-Layer Mouthguard during Pressure Formation. Dental Traumatology, 35, 285-290.
https://doi.org/10.1111/edt.12472
[11]  Takahashi, M., Koide, K., Satoh, Y. and Iwasaki, S. (2016) Heating Methods for Reducing Unevenness Softening of Mouthguard Sheets in Vacuum-Pressure Formation. Dental Traumatology, 32, 316-320.
https://doi.org/10.1111/edt.12254
[12]  Takahashi, M. and Bando, Y. (2020) Thermoforming Technique for Suppressing Reduction in Mouthguard Thickness: Part 2 Effect of Model Height and Model Moving Distance. Dental Traumatology, 36, 543-550.
https://doi.org/10.1111/edt.12554
[13]  Takahashi, M. and Bando, Y. (2021) Fabrication Method to Maintain Mouthguard Thickness Regardless of the Model Angle. Dental Traumatology, 37, 131-137.
https://doi.org/10.1111/edt.12584
[14]  Waked, E.J. and Caputo, A.A. (2005) Thickness and Stiffness Characteristics of Custom-Made Mouthguard Materials. Quintessence International, 36, 462-466.
[15]  Tunc, E.S., Ozdemir, T.E. and Arici, S. (2013) Postfabrication Thickness of Single- and Double-Layered Pressure-Formed Mouthguards. Dental Traumatology, 29, 378-382.
https://doi.org/10.1111/edt.12010
[16]  Yamada, J. and Maeda, Y. (2007) Thermoforming Process for Fabricating Oral Appliances: Influence of Heating and Pressure Application Timing on Formability. Journal of Prosthodontics, 16, 452-456.
https://doi.org/10.1111/j.1532-849X.2007.00222.x
[17]  Takahashi, M., Koide, K., Suzuki, H. and Iwasaki, S. (2016) Optimal Heating Condition of Ethylene-Vinyl Acetate Co-Polymer Mouthguard Sheet in Vacuum-Pressure Formation. Dental Traumatology, 32, 311-315.
https://doi.org/10.1111/edt.12248
[18]  Takahashi, M., Satoh, Y. and Iwasaki, S. (2017) Effect of Thermal Shrinkage during Thermoforming on the Thickness of Fabricated Mouthguards: Part 2 Pressure Formation. Dental Traumatology, 33, 106-109.
https://doi.org/10.1111/edt.12291
[19]  Takahashi, M. and Bando, Y. (2022) Effect of Sheet Extrusion Direction on Laminated Mouthguard Thickness: An in Vitro Study. Dental Traumatology, 38, 439-447.
https://doi.org/10.1111/edt.12763
[20]  Takahashi, M. and Bando, Y. (2022) Dependence of Thermoformed Mouthguard Thickness on Model Height in Single-Layer and Laminated Mouthguards. Materials Sciences and Applications, 13, 469-478.
https://doi.org/10.4236/msa.2022.138028
[21]  Takahashi, M. and Bando, Y. (2023) In Vitro Study of How the Undercut Amount on the Model Labial Side Affects the Reduction Rate of Laminated Mouthguard Thickness. Dental Traumatology, 39, 206-213.
https://doi.org/10.1111/edt.12820
[22]  Bemelmanns, P. and Pfeiffer, P. (2001) Shock Absorption Capacities of Mouthguards in Different Types and Thicknesses. International Journal of Sports Medicine, 22, 149-153.
https://doi.org/10.1055/s-2001-11342
[23]  Westerman, B., Stringfellow, P.M. and Eccleston, J.A. (2002) EVA Mouthguards: How Thick Should They Be? Dental Traumatology, 18, 24-27.
https://doi.org/10.1034/j.1600-9657.2002.180103.x

Full-Text

comments powered by Disqus

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133