河北省某医院供热与空调系统的节能改造研究浅析
A Brief Analysis of the Energy-Saving Renovation of the Heating and Air-Conditioning System of a Hospital in Hebei Province

DOI: 10.12677/AEPE.2024.121001, PP. 1-7

Keywords: 采暖系统,空调系统,节能减排,空气源热泵,土壤源热泵
Heating System
, Air Conditioning System, Energy Saving and Emission Reduction, Air Source Heat Pump, Ground Source Heat Pump

Full-Text   Cite this paper   Add to My Lib

Abstract:

河北省公共机构的供热和空调系统能耗较大,需要进行整体优化以减少能耗。本研究针对河北省某医院的供热和空调系统进行了深入分析和评估,探讨了潜在的节能和效率改进措施。分析结果表明,热源设备选型过大,建议加装气候补偿装置;供热和空调系统的循环水泵需要加装变频控制系统以降低能耗;替换传统热源为土壤源热泵能够显著提高系统的能效和降低运行成本。此外,生活热水辅热系统也可以采用空气源热泵以实现节能。综合各项改造措施后,可显著提高医院的能源效率,减少二氧化碳排放。
Heating and air-conditioning systems in public institutions in Hebei Province consume large amounts of energy and need to be optimized as a whole to reduce energy consumption. This study provides an in-depth analysis and assessment of the heating and air-conditioning system of a hospital in Hebei Province and explores potential energy-saving and efficiency improvement measures. The results of the analysis indicate that the heat source equipment is oversized and it is recommended that a climate compensation device be added; the circulating water pumps of the heating and air conditioning system need to be retrofitted with a variable frequency control system to reduce energy consumption; and the replacement of the traditional heat source with a soil source heat pump can significantly improve the energy efficiency of the system and reduce the operating costs. In addition, the domestic hot water auxiliary heating system can also use air-source heat pumps to achieve energy savings. The combination of all the retrofit measures can significantly improve the energy efficiency of the hospital and reduce carbon dioxide emissions.

References

[1]  李红. 医院工程中暖通空调节能改造效果分析[J]. 黑龙江科学, 2023, 14(22): 144-146.
[2]  钱杰, 徐云华, 金永春, 等. 某专科医院住院楼热水系统节能改造实践及经济性分析[J]. 暖通空调, 2023, 53(S1): 364-366.
[3]  李慧娟, 张可欣. 广州某医院综合节能改造案例分析[J]. 科技创新与应用, 2022, 12(35): 154-157.
https://doi.org/10.19981/j.CN23-1581/G3.2022.35.038
[4]  吴耀洲. 暖通空调系统节能设计研究[J]. 装备制造技术, 2023(6): 212-214, 222.
[5]  彭晓娟. 高大空间公共建筑暖通空调系统设计要点分析[J]. 中国建筑装饰装修, 2022(6): 96-98
[6]  刘曦. 青岛地区既有建筑节能改造探讨[D]: [硕士学位论文]. 青岛: 中国海洋大学, 2008: 5.
[7]  Okamoto, S. (2007) Energy Saving in a Hospital: Assessing Economic and Technical Potential. In: Cen, K., Chi, Y. and Wang, F., Eds., Challenges of Power Engineering and Environment, Springer, Berlin, 1305-1309.
https://doi.org/10.1007/978-3-540-76694-0_245
[8]  Okamoto, S. (2008) Energy Consumption and Technical Po-tential of Energy Saving in a Hospital. 6th International Energy Conversion Engineering Conference, Cleveland, 28-30 July 2008, 691-697.
https://doi.org/10.2514/6.2008-5622
[9]  Okamoto, S. (2007) Technical Potential of Energy Saving in a Hospital by Cogeneration System. 5th International Energy Conversion Engineering Conference and Exhibit (IECEC), St. Louis, 25-27 June 2007, Article 4759.
https://doi.org/10.2514/6.2007-4759
[10]  沃尔特·弗农, 吕晓婧. 从忽视到重视——美国绿色医院建筑演进过程[J]. 中国医院建筑与装备, 2009, 10(7): 26-29.
[11]  韩强, 刘培陶, 魏翠琴, 等. 供暖季太阳能热泵冷热暖联供系统节能减排分析[J]. 制冷与空调(四川), 2021, 35(6): 884-888.
[12]  刘野, 闵芸. 上海大中型医院综合节能改造案例分析[J]. 上海节能, 2022(5): 639-643.
https://doi.org/10.13770/j.cnki.issn2095-705x.2022.05.017
[13]  邹国华. 暖通空调系统中节能环保技术的探讨与思考[J]. 居舍, 2019(9): 74.
[14]  刘艳峰, 宋梦瑶, 周勇, 等. 分区串并联式太阳能-地源热泵跨季节蓄热组合系统性能研究[J]. 太阳能学报, 2021, 42(12): 71-79.
https://doi.org/10.19912/j.0254-0096. tynxb.2020-0063
[15]  胡海龙. 探究地源热泵节能环保技术在暖通空调系统中的应用[J]. 城市住宅, 2018, 25(5): 43-46.
[16]  周巧利. 地源热泵复合技术在高校建筑节能改造的工程应用[J]. 能源与节能, 2023(11): 84-88.
https://doi.org/10.16643/j.cnki.14-1360/td.2023.11.029
[17]  陈军, 毛斯影. 某三甲医院综合节能改造实例分析及思考[J]. 建筑热能通风空调, 2022, 41(7): 61-63+35.