全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...

Flow Rate Measurement of Gravity Infusion Set and Functional Evaluation of Drop Counter: A Pilot Study

DOI: 10.4236/jbise.2024.177010, PP. 129-135

Keywords: Gravity Infusion Set, Drop Counter, IV Fluids, Flow Rate, Trumpet Curves

Full-Text   Cite this paper   Add to My Lib

Abstract:

Developing a novel drop counter by introducing the Internet of Things concept has been vigorously conducted in recent years. Understanding the newly introduced drop counter’s flow rate control accuracy and flow rate count feature is essential for improving safety in infusion management. This study aimed to verify if the new drop counters could secure accurate flow rate and drip count by conducting actual flow rate measurements using gravimetry and functional evaluation. A drop counter was attached to each drip chamber of the infusion set, and an IV drip was conducted at the 100 ml/h flow rate. The weight of discharged physiological saline was measured to plot trumpet curves. Next, three different types of drop counters were evaluated to determine if they maintained drip count accuracy according to the changes in their position angles. The flow rate errors in all conditions indicated trumpet-like curves, exhibiting an overall error range within ±10% in all observation windows. Although every drop counter successfully detected and measured dripping, it was challenging in some counters to detect dripping when the drip chamber was tilted. In comparing adult and pediatric IV sets, the adult IV set was found to be less likely to detect dripping in the angled position. No significant differences in results were confirmed between high and low flow rates, suggesting that the drop count function would not be affected by the flow rate in the ranges of typical infusion practices. Doppler sensors have a wide range of measurements and high sensitivity; the dripping was detected successfully even when the drip chamber was tilted, probably due to the advantages of these sensors. In contrast, miscounts occurred in those equipped with infrared sensors, which could not detect light intensity changes in tilted positions. Understanding the tendencies in flow rate errors in infusion can be valuable information for infusion management.

References

[1]  Han, J. and Lee, H. (2023) Control Volume Analysis of the Infusion Rate in Cephalic and Median Cubital Veins Based on Infusion Bag Height and Peripheral Venous Catheter Inner Diameter: Application of Bernoulli’s Equation and Consideration of Frictional Forces. Journal of Multidisciplinary Healthcare, 16, 3609-3618.
https://doi.org/10.2147/jmdh.s409050
[2]  Crass, R.E. and Vance, J.R. (1985) In Vivo Accuracy of Gravity-Flow I.V. Infusion Systems. American Journal of Health-System Pharmacy, 42, 328-331.
https://doi.org/10.1093/ajhp/42.2.328
[3]  Omura, T., Fujisawa, H., Muro, C., Yamashita, N., Kuroda, N., Hamaguchi, T., et al. (2008) Factors Affecting Infusion Rate of Paclitaxel Injection Solution When Using Infusion Pumps. Iryo Yakugaku (Japanese Journal of Pharmaceutical Health Care and Sciences), 34, 467-473.
https://doi.org/10.5649/jjphcs.34.467
[4]  Ko, E., Song, Y.J., Choe, K., Park, Y., Yang, S. and Lim, C.H. (2022) The Effects of Intravenous Fluid Viscosity on the Accuracy of Intravenous Infusion Flow Regulators. Journal of Korean Medical Science, 37, e71.
https://doi.org/10.3346/jkms.2022.37.e71
[5]  Carleton, B.C., Cipolle, R.J., Larson, S.D. and Canafax, D.M. (1991) Method for Evaluating Drip-Rate Accuracy of Intravenous Flow-Regulating Devices. American Journal of Health-System Pharmacy, 48, 2422-2426.
https://doi.org/10.1093/ajhp/48.11.2422
[6]  Hong, K.Y., Lee, E.K., Kim, Y., Choi, D. and Min, J. (2023) Effects of Infusion Tubing Line Lengths and Syringe Sizes on Infusion System Compliance: An Experimental Study Using a Syringe-Type Infusion Pump at Low Flow Rate. Journal of Clinical Monitoring and Computing, 37, 1379-1386.
https://doi.org/10.1007/s10877-023-00973-y
[7]  Park, K., Lee, J., Kim, S., Kim, J., Kim, I., Choi, S.P., et al. (2013) Infusion Volume Control and Calculation Using Metronome and Drop Counter Based Intravenous Infusion Therapy Helper. International Journal of Nursing Practice, 19, 257-264.
https://doi.org/10.1111/ijn.12063
[8]  Buonora, J.E. (2019) Management of Gravity Intravenous Infusions in an Austere Environment Using the DripAssist Infusion Rate Monitor. American Association of Nurse Anesthetists Journal, 87, 65-70.
[9]  Markinashella, D., Risma, P. and Husni, N.L. (2023) Revolutionizing IV Infusions: Empowering Care with the DripControl+ App for Real-Time Monitoring and Precision Management. International Journal of Advanced Health Science and Technology, 3, 274-282.
https://doi.org/10.35882/ijahst.v3i4.280
[10]  Mohamad, A. and Lavanya, R. (2020) Intravenous (IV) Drip Rate Controlling and Monitoring for Risk-Free IV Delivery. International Journal of Engineering Research & Technology, 9, 967-971.
[11]  Atanda, O., West, J., Stables, T., Johnson, C., Merrifield, R. and Kinross, J. (2023) Flow Rate Accuracy of Infusion Devices within Healthcare Settings: A Systematic Review. Therapeutic Advances in Drug Safety, 14, 1-11.
https://doi.org/10.1177/20420986231188602
[12]  Loner, C., Acquisto, N.M., Lenhardt, H., Sensenbach, B., Purick, J., Jones, C.M.C., et al. (2018) Accuracy of Intravenous Infusion Flow Regulators in the Prehospital Environment. Prehospital Emergency Care, 22, 645-649.
https://doi.org/10.1080/10903127.2018.1436208
[13]  Voss, G.I. and Butterfield, R.D. (2000) Medical Instruments and Devices. CRC Press Inc., 156.
[14]  Rooker, J.C. and Gorard, D.A. (2007) Errors of Intravenous Fluid Infusion Rates in Medical Inpatients. Clinical Medicine, 7, 482-485.
https://doi.org/10.7861/clinmedicine.7-5-482
[15]  Mousavi, M., Khalili, H. and Dashti-Khavidaki, S. (2012) Errors in Fluid Therapy in Medical Wards. International Journal of Clinical Pharmacy, 34, 374-381.
https://doi.org/10.1007/s11096-012-9620-8

Full-Text

comments powered by Disqus

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133

WeChat 1538708413