The Peripheral Hospital as Focal Point for Pacemaker Activity: Review of the Last 300 Implantations Carried out at the Haute Correze Hospital Center

DOI: 10.4236/wjcd.2024.149047, PP. 547-556

Keywords: Peripheral Hospital, Pacemaker, Haute Correze Hospital Center

Full-Text   Cite this paper   Add to My Lib

Abstract:

Background: Pacemaker implantation is a very old activity which has revolutionized the cardiology practice throughout the world. This activity is effective at the Haute Correze Hospital Center since more than 20 years. Due to progress in this area, and the increasing request within this center located at the outskirts of town, we set out to evaluate our pacemaker activity in general and more specifically to assess the post-procedural complications in our series patients. Methodology: This was a retrospective longitudinal study. Data were recorded for period of 90 months from 27/05/2016 to 19/11/2023. This data collection was possible via a specific register completed by computerized patient data from the SillageTM software. All files of patients implanted with single or dual chamber pacemakers were included, generator replacements, upgrading procedures and addition of leads were excluded. The sampling was non-probabilistic, consecutive and non-exhaustive. Statistical analysis was carried out using the Excel 2019 spreadsheet and SPSS version 23 software. The quantitative variables were presented as mean ± standard deviation, the qualitative data as proportions. Results: A total of 303 first-time pacemaker’s implantations were carried out during the study period (rate of 40 per year). The average age in the population was 79.7 ± 9.4 years (44 - 99 years) with a male predominance of 63.7% (n = 193). Atrioventricular block (2nd and 3rd degree) was the main indication for pacemaker implantation in 42.9% of cases (n = 130). Patients were most often implanted with a dual-chamber pacemaker (57.7%, n = 175). The approach was most often cephalic in 72.6% of cases (n = 220), followed by the subclavian access in 27.4% of cases (n = 84). The average fluoroscopy time was 7.9 min ± 2.4 (1 - 43). The average irradiation dose in gray/cm2 was 12.4 ± 9.3 (0.22 - 117.5). The average length of hospitalization was 7 ± 4 (2 - 26) days. The overall complication rate at one year was 12.9% (n = 39). These complications are distributed as follows: Leads dislodgement in 8.2% (n = 25), hematoma 3.6% (n = 11) all without clinical consequences, pneumothorax 0.7% (n = 2), both cases of pneumothorax did not require specific care, infection (superficial) in 0.3% (n = 1). Leads dislodgement occurred after a median time of 18 days (IQR: 3 - 36). The earliest dislodgement was observed on D0 and the latest on D207. No serious complications were recorded. The average atrial threshold at

References

[1]  Timmis, A., Townsend, N., Gale, C., Grobbee, R., Maniadakis, N., Flather, M., et al. (2018) European Society of Cardiology: Cardiovascular Disease Statistics 2017. European Heart Journal, 39, 508‑579.
[2]  Burri, H., Starck, C., Auricchio, A., Biffi, M., Burri, M., D’Avila, A., et al. (2021) EHRA Expert Consensus Statement and Practical Guide on Optimal Implantation Technique for Conventional Pacemakers and Implantable Cardioverter-Defibrillators: Endorsed by the Heart Rhythm Society (HRS), the Asia Pacific Heart Rhythm Society (APHRS), and the Latin-American Heart Rhythm Society (LAHRS). EP Europace, 23, 983-1008.
https://doi.org/10.1093/europace/euaa367
[3]  Reynolds, M.R., Cohen, D.J., Kugelmass, A.D., Brown, P.P., Becker, E.R., Culler, S.D., et al. (2006) The Frequency and Incremental Cost of Major Complications among Medicare Beneficiaries Receiving Implantable Cardioverter-Defibrillators. Journal of the American College of Cardiology, 47, 2493-2497.
https://doi.org/10.1016/j.jacc.2006.02.049
[4]  Ellenbogen, K.A., Hellkamp, A.S., Wilkoff, B.L., Camunãs, J.L., Love, J.C., Hadjis, T.A., et al. (2003) Complications Arising after Implantation of DDD Pacemakers: The MOST Experience. The American Journal of Cardiology, 92, 740-741.
https://doi.org/10.1016/s0002-9149(03)00844-0
[5]  Kirkfeldt, R.E., Johansen, J.B., Nohr, E.A., Jorgensen, O.D. and Nielsen, J.C. (2013) Complications after Cardiac Implantable Electronic Device Implantations: An Analysis of a Complete, Nationwide Cohort in Denmark. European Heart Journal, 35, 1186-1194.
https://doi.org/10.1093/eurheartj/eht511
[6]  Nowak, B., Misselwitz, B., Erdogan, A., Funck, R., Irnich, W., Israel, C.W., et al. (2009) Do Gender Differences Exist in Pacemaker Implantation—Results of an Obligatory External Quality Control Program. Europace, 12, 210-215.
https://doi.org/10.1093/europace/eup312
[7]  Tobin, K., Stewart, J., Westveer, D. and Frumin, H. (2000) Acute Complications of Permanent Pacemaker Implantation: Their Financial Implication and Relation to Volume and Operator Experience. The American Journal of Cardiology, 85, 774-776.
https://doi.org/10.1016/s0002-9149(99)00861-9
[8]  Eberhardt, F. (2005) Long Term Complications in Single and Dual Chamber Pacing Are Influenced by Surgical Experience and Patient Morbidity. Heart, 91, 500-506.
https://doi.org/10.1136/hrt.2003.025411
[9]  Uslan, D.Z. (2007) Permanent Pacemaker and Implantable Cardioverter Defibrillator Infection. Archives of Internal Medicine, 167, 669-675.
https://doi.org/10.1001/archinte.167.7.669
[10]  Lee, D.S., Krahn, A.D., Healey, J.S., Birnie, D., Crystal, E., Dorian, P., et al. (2010) Evaluation of Early Complications Related to De Novo Cardioverter Defibrillator Implantation. Journal of the American College of Cardiology, 55, 774-782.
https://doi.org/10.1016/j.jacc.2009.11.029
[11]  Cheng, A., Wang, Y., Curtis, J.P. and Varosy, P.D. (2010) Acute Lead Dislodgements and In-Hospital Mortality in Patients Enrolled in the National Cardiovascular Data Registry Implantable Cardioverter Defibrillator Registry. Journal of the American College of Cardiology, 56, 1651-1656.
https://doi.org/10.1016/j.jacc.2010.06.037
[12]  Dębski, M., Ulman, M., Ząbek, A., Boczar, K., Haberka, K., Kuniewicz, M., et al. (2018) Lead-Related Complications after DDD Pacemaker Implantation. Kardiologia Polska, 76, 1224-1231.
https://doi.org/10.5603/kp.a2018.0089
[13]  Udo, E.O., Zuithoff, N.P.A., van Hemel, N.M., de Cock, C.C., Hendriks, T., Doevendans, P.A., et al. (2012) Incidence and Predictors of Short-and Long-Term Complications in Pacemaker Therapy: The FOLLOWPACE Study. Heart Rhythm, 9, 728-735.
https://doi.org/10.1016/j.hrthm.2011.12.014
[14]  Gadler, F., Valzania, C. and Linde, C. (2014) Current Use of Implantable Electrical Devices in Sweden: Data from the Swedish Pacemaker and Implantable Cardioverter-Defibrillator Registry. Europace, 17, 69-77.
https://doi.org/10.1093/europace/euu233
[15]  Ghani, A., Delnoy, P.P.H.M., Ramdat Misier, A.R., Smit, J.J.J., Adiyaman, A., Ottervanger, J.P., et al. (2014) Incidence of Lead Dislodgement, Malfunction and Perforation during the First Year Following Device Implantation. Netherlands Heart Journal, 22, 286-291.
https://doi.org/10.1007/s12471-014-0556-6
[16]  Tseng, A.S., Shipman, J.N., Lee, J.Z., Mi, L., Amin, M., Killu, A.M., et al. (2019) Incidence, Patterns, and Outcomes after Transvenous Cardiac Device Lead Macrodislodgment: Insights from a Population-Based Study. Heart Rhythm, 16, 140-147.
https://doi.org/10.1016/j.hrthm.2018.07.026
[17]  Qin, D., Filippaios, A., Murphy, J., Berg, M., Lampert, R., Schloss, E.J., et al. (2022) Short-and Long-Term Risk of Lead Dislodgement Events: Real-World Experience from Product Surveillance Registry. Circulation: Arrhythmia and Electrophysiology, 15, e011029.
https://doi.org/10.1161/circep.122.011029
[18]  Takeda, T., Tsubaki, A., Ikeda, Y., Kato, R., Kojima, S. and Makita, S. (2023) Impact of Raising the Upper Extremity Siding Cardiac Implantable Electrical Devices on Postoperative Safety. Journal of Arrhythmia, 39, 586-595.
https://doi.org/10.1002/joa3.12884
[19]  Mlynarski, R., Mlynarska, A., Joniec, M., Gladysz-Wanha, S., Honkowicz, M., Stachanczyk, J., et al. (2022) Predictors of Early Cardiac Implantable Electronic Device Lead Dislodgement in the Elderly. International Journal of Environmental Research and Public Health, 19, Article 14766.
https://doi.org/10.3390/ijerph192214766
[20]  Tarakji, K.G., Mittal, S., Kennergren, C., Corey, R., Poole, J.E., Schloss, E., et al. (2019) Antibacterial Envelope to Prevent Cardiac Implantable Device Infection. New England Journal of Medicine, 380, 1895-1905.
https://doi.org/10.1056/nejmoa1901111
[21]  Kang, F., Liu, P., Liang, L., Lin, Y., Xie, S., He, Y., et al. (2017) Effect of Pocket Irrigation with Antimicrobial on Prevention of Pacemaker Pocket Infection: A Meta-Analysis. BMC Cardiovascular Disorders, 17, Article No. 256.
https://doi.org/10.1186/s12872-017-0689-9

Full-Text

comments powered by Disqus

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133