Nucleus  2010 

Desmontaje de un irradiador autoblindado de investigación del tipo MPX--25M

Keywords: shielding, irradiation devices, decommissioning, gamma sources, charges.

Full-Text   Cite this paper   Add to My Lib

Abstract:

abstract this paper describes the dismantling of a category i selfshielded gamma irradiation facility model mpx--25m. the following specific objectives were established: a) to identify aspects of the insurance contract, human and technical resources b) to assess the radiological situation of the process and c) to analyze the potential radiological extraordinary events in each step of the process by providing the appropriate answers. the assessment of radiological events may serve as a reference for addressing the process of dismantling other similar irradiators.